Martínez-Ibernón, Ana; Gasch, Isabel; Gandía-Romero, Jose M.; Soto Camino, Juan(Institute of Electrical and Electronics Engineers, 2022-07-01)
[EN] Monitoringreinforced concrete structures (RCS)
is essential to ensure their service life. Monitoring the parameters associated with deterioration processes can be key
for proactive maintenance. A gap exists between ...
Martínez-Ibernón, Ana; Gandía-Romero, Jose M.; Gasch, Isabel; Valcuende Payá, Manuel Octavio(International Center for Numerical Methods in Engineering (CIMNE), 2020-10-23)
[EN] The monitoring of reinforced concrete structures allows us to detect the presence of aggressive agents into of the concrete matrix, on site and in a real time. These aggressive agents can produce the unexpected failure ...
Ramón, José Enrique; Martínez, Isabel; Gandía-Romero, Jose M.; Soto Camino, Juan(Springer-Verlag, 2022-12)
[EN] Potential step voltammetry (PSV) was introduced in earlier works as an advantageous alternative to traditional methods for
measuring corrosion rate in reinforced concrete. The present study aims to improve PSV to ...
Gandía-Romero, Jose M.; Ramón Zamora, José Enrique; Bataller Prats, Román; Palací-López, Daniel Gonzalo; Valcuende Payá, Manuel Octavio; Soto Camino, Juan(Springer Verlag (Germany), 2017-02)
Differences between the cell cross section and the electrodes area produce a heterogeneous
distribution of the electric field that causes a non-linear relationship between electric resistance and distance for low values ...
Lliso-Ferrando, Josep Ramon; Valcuende Payá, Manuel Octavio; Gasch, Isabel; Gandía-Romero, Jose M.(Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico, 2019-07-05)
[EN] Corrosion of the steel embedded in reinforced concrete is one the biggest problems that affects concrete structures durability. High alkalinity of this material protects the steel creating a passive layer, which ...
Ramón Zamora, José Enrique; Gandía Romero, José Manuel; Valcuende Payá, Manuel Octavio; Bataller Prats, Román(Universitat Politècnica de València, 2016-06-21)
[EN] Corrosion is one of the main triggering factors affecting the service life and durability of structures. Several methods are used for corrosion studies but electrochemical techniques are the most commonly applied. ...
Lliso-Ferrando, Josep Ramon; Gandía-Romero, Jose M.; Martínez-Ibernón, Ana(REDINE, 2021-09-30)
[EN] The statistics on the employment of graduates of the Bachelor¿s Degree in Technical Architecture show that there
are very few students who decide to focus on scientific research at the end of their studies. The causes ...
Guallar Lamiel, Marta Aurora(Universitat Politècnica de València, 2022-10-14)
[ES] El presente trabajo académico tiene como objetivo analizar y proponer un cambio de uso en el edificio situado en Calle Sorní nº14 de València. Existen dos objetivos principales en este proyecto, por un lado adquirir ...
Gandía Romero, José Manuel; Iborra Lucas, Milagro; Martínez Ibernón, Ana(Editorial Universitat Politècnica de València, 2021-11-02)
[EN] Construction II (Flat roofs and sloped roofs) and Construction III (Facades,
partitions and claddings) are two mandatoy subjects of second-year courses.
The new European Higher Education Area and the competence-based ...
Iborra Lucas, Milagro; Gandía Romero, José Manuel(Editorial Universitat Politècnica de València, 2021-11-02)
[EN] Traditional classes develop a passive attitude of students to their learning,
which contradicts expectations in the final assessment where students are
expected to demonstrate the practical skills they have been ...
The use of a voltammetric electronic tongue as a tool to monitor grape ripeness is proposed herein. The electronic
tongue consists of eight metallic electrodes housed inside a stainless steel cylinder. The study was carried ...
Lliso-Ferrando, Josep Ramon; Gandía-Romero, Jose M.; Soto Camino, Juan; Valcuende Payá, Manuel Octavio(MDPI AG, 2023-09-25)
[EN] This work aims to study the corrosion performance of six concretes in the marine environment: three ordinary concretes (C30, C40 and C50); one high-performance concrete (C90); two ultra high-performance concretes, one ...
Monzón, Pablo; Ramón Zamora, José Enrique; Gandía-Romero, Jose M.; Valcuende Payá, Manuel Octavio; Soto Camino, Juan; Palací-López, Daniel(John Wiley & Sons, 2019-02)
[EN] There are few techniques available to calculate the corrosion rate (i(corr)) of reinforcing steel in concrete structures. This is due not only to a lack of instrumentation but also because it is necessary to take into ...
Valcuende Payá, Manuel Octavio; Lliso-Ferrando, Josep Ramon; Roig-Flores, Marta; Gandía-Romero, Jose M.(MDPI AG, 2021-04)
[EN] The aim of this experimental work was to study the porous structure of Ultra-High-Performance Fibre-Reinforced Concretes (UH) made with different fibre volume contents (0%, 1%, 2%) under several curing conditions ...
Ramón, J.E.; Gandía-Romero, Jose M.; Bataller Prats, Román; Alcañiz Fillol, Miguel; Valcuende Payá, Manuel Octavio; Soto Camino, Juan(Elsevier, 2020-07)
[EN] This paper presents a Potentiostatic Step Voltammetry approach to corrosion rate measurement of reinforcements in concrete. We have termed this approach PSV-TE since it is based on the Tafel extrapolation method, but ...
Voltammetric techniques (open circuit potential, linear polarisation resistance and cyclic
voltammetry) have been applied to study the corrosion of carbon steel in water. The study has
been performed in aqueous solutions ...
Pallardó Serrano, Pau(Universitat Politècnica de València, 2013-11-08)
El objetivo de este proyecto es estudiar los diferentes factores que intervienen en los procesos de corrosión de las armaduras metálicas del hormigón armado. En primer lugar se analiza la documentación existente para ...
Ramón Zamora, José Enrique; Gandía-Romero, Jose M.; Bataller Prats, Román; López, Juan A.; Valcuende Payá, Manuel Octavio; Soto Camino, Juan(John Wiley & Sons, 2022-11)
[EN] The excellent high-durability features of ultra-high performance fibre-reinforced concrete (UHPFRC) have been verified in laboratory studies, but its performance under service conditions are being studied. Indeed, ...
Gandía Romero, José Manuel(Universitat Politècnica de València, 2015-03-31)
La corrosión de las armaduras es una de las principales causas que afectan a la
durabilidad de las estructuras y a su vida útil. La carbonatación del hormigón y la
acción de iones agresivos, principalmente los cloruros, ...
Ramón Zamora, José Enrique(Universitat Politècnica de València, 2018-10-30)
La durabilidad de una estructura de hormigón armado puede verse seriamente comprometida por la corrosión de las armaduras. En una inspección visual la corrosión solo se detecta cuando el daño está ya muy avanzado, lo que ...