[EN] Background: Diagnostic Task Force Criteria (TFC) for arrhythmogenic cardiomyopathy (AC) exhibit poor performance for left dominant forms. TFC only include right ventricular (RV) dysfunction (akinesia, dyssynchrony, ...
Castells Ramón, Francisco Sales(Universitat Politècnica de València, 2020-01-07)
Given the electromechanical parameters of a loudspeaker, this virtual lab plots peak displacement, velocity and acceleration curves of the cone. In this virtual lab the cone is assumed to move as a rigid body.
[EN] The present study aims to design and fabricate a system capable of generating heterogeneities on the epicardial surface of an isolated rabbit heart perfused in a Langendorff system. The system consists of thermoelectric ...
[EN] Although standard 12-lead ECG is the primary
technique in cardiac diagnostic, detecting different
cardiac diseases using single or reduced number of leads
is still challenging. The purpose of our team, itaca-UPV,
is ...
[EN] Background and objectives: Macroreentrant atrial tachyarrhythmias (MRATs) can be caused by different reentrant circuits. The treatment for each MRAT type may require ablation at different sites, either at the right ...
Segarra Górriz, Izan(Universitat Politècnica de València, 2022-10-14)
[ES] La irrupción de los navegadores electroanatómicos cardiacos en la electrofisiología ha supuesto un desarrollo tecnológico sustancial en los últimos años. Aún así, el conocimiento sobre los mecanismos desencadenantes ...
BackgroundThe dominant atrial frequency is a key parameter for the analysis of atrial fibrillation (AF) from intracardiac recordings. The preprocessing approach employed by Botteron et al. in an early work is able to ...
[EN] Objective:
The aim of this study is to propose a method to reduce the sensitivity of the estimated omnipolar electrogram (oEGM) with respect to the angle of the propagation wavefront.
Methods:
A novel configuration ...
Amorós Pagán, Sonia(Universitat Politècnica de València, 2019-09-18)
[ES] El proyecto nace de la idea de crear un producto audiovisual sobre la Capitanía de Moros 2019, para elaborar un trabajo de carácter profesional. Se trata de un producto audiovisual completo sobre las fiestas de Moros ...
During atrial fibrillation (AF), multiple wandering propagation wavelets at high rates drift around both atria under controversial hierarchical models. Antiarrhythmic drugs modify the cardiac ionic currents supporting the ...
[EN] Ablation of pulmonary veins has emerged as a key procedure for normal rhythm restoration in atrial fibrillation patients. However, up to half of ablated Atrial fibrillation (AF) patients suffer recurrences during the ...
Cervigón Abad, Raquel; Moreno, J.; Reilly, Richard; Perez-Villacastin, J.; Castells Ramón, Francisco Sales(IOP Publishing: Hybrid Open Access, 2012-10)
The mechanism underlying atrial fibrillation (AF) remains poorly understood. Multiple wandering propagation wavelets drifting through both atria under hierarchical models are not understood. Some pharmacological drugs, ...
Castells Ramón, Francisco Sales; Vives Gilabert, Yolanda(Universitat Politècnica de València, 2020-06-09)
En este laboratorio virtual se muestra la forma de onda en cada etapa de un rectificador de media onda con filtro C y carga resistiva:
- Señal de entrada
- Señal rectificada
- Salida filtrada
Castells Ramón, Francisco Sales; Vives Gilabert, Yolanda(Universitat Politècnica de València, 2020-06-09)
En este laboratorio virtual se muestra la forma de onda en cada etapa de un rectificador de media onda con filtro C y estabilizador Zener:
- Señal de entrada
- Señal rectificada
- Señal en el condensador
- Señal ...
Castells Ramón, Francisco Sales; Vives Gilabert, Yolanda(Universitat Politècnica de València, 2020-06-25)
En este laboratorio virtual se muestra la forma de onda en cada etapa de un rectificador de onda completa con filtro C y carga resistiva:
- Señal de entrada
- Señal rectificada
- Salida filtrada
Castells Ramón, Francisco Sales; Vives Gilabert, Yolanda(Universitat Politècnica de València, 2020-06-03)
En este laboratorio virtual se muestra la forma de onda en cada etapa de un rectificador de onda completa con filtro C y estabilizador Zener:
- Señal de entrada
- Señal rectificada
- Señal en el condensador
- Señal ...
Cervigón Abad, Raquel(Universitat Politècnica de València, 2009-06-25)
La fibrilación auricular es la arritmia más frecuente en la práctica clínica, con una prevalencia que alcanza el 10% en la población mayor de 70 años, y unas perspectivas de incremento en consonancia con el aumento de la ...
Alfonso Pastor, Lorena; Mirambell Alberola, Laura(Universitat Politècnica de València, 2013-10-11)
Antes de la aparición de la televisión, la radio ha venido siendo el transmisor de los diferentes tipos de acontecimientos deportivos. Tras la aparición de la propia televisión, lejos de desbancar a la radio, ésta ha ...
Castells Ramón, Francisco Sales(Universitat Politècnica de València, 2019-12-27)
Given the electromechanical parameters of a speaker, this virtual lab represents the sound pressure level (at 1m) as a function of frequency. Four curves are represented, according to different angles: on-axis, 30º, 60º an 90º.