Ciborowski, M.; Catalá Icardo, Mónica; García Mateo, J.V.; Martínez Calatayud, J.(Elsevier, 2004-11-19)
The present manuscript deals with a simple and sensitive flow-injection method for the chemiluminescent determination of thiazides. The method is based on the on-line photodegradation and chemiluminescent determination of ...
[EN] A flow injection analysis (FIA) manifold for the determination of penicillamine in pharmaceutical preparations is proposed. The manifold includes a solid-phase reactor for the in situ production of the derivatizing ...
Polo Martí, E.; Catalá Icardo, Mónica; Lahuerta Zamora, L.; Antón Fos, G. M.; Martínez Calatayud, J.(Elsevier Masson, 2004-12-06)
The present manuscript is dealing with the application of molecular connectivity calculations to predict the chemiluminescent behaviour
of ergot alkaloids when they react with common strong oxidants in liquid phase. Twenty ...