Fernandez-Cavero, Vanessa; Morinigo-Sotelo, Daniel; Duque-Perez, Oscar; Pons Llinares, Joan(Institute of Electrical and Electronics Engineers, 2017)
[EN] Fault detection in induction motors operating in non-stationary regimes has become a need in today's industry. Most of the works published deal with line-fed motors. Nevertheless, the number of inverterfed induction ...
González Espín, Francisco José; Patrao Herrero, Iván; Figueres Amorós, Emilio; Gabriel Garcerá(Institute of Electrical and Electronics Engineers (IEEE), 2013)
Grid connected voltage source inverters may be controlled in the stationary reference frame by means of the infinite impulse response (IIR) P+Resonat regulator. This regulator is able to correctly track fixed frequency ...
Oltra Gómez, Jesús(Universitat Politècnica de València, 2020-05-18)
[ES] En el presente proyecto se lleva a cabo el diseño de una instalación solar fotovoltaica con el objetivo de suministrar energía eléctrica a un edificio con una demanda pico de 42 kW y, de esta forma, cubrir en medida ...
Sendra Andrés, Adrià(Universitat Politècnica de València, 2018-01-04)
[EN] Calculations for the correct sizing of a 100 kWp photovoltaic installation to supply the pumps and functions programmed in c language to control them.
Montes Descalzo, Miriam(Universitat Politècnica de València, 2019-10-01)
[ES] El nuevo centro acuático deportivo de Segorbe, situado en la calle Max Aub, es el único recinto que dispone de piscina climatizada en toda la comarca por lo que abastece a la población de Segorbe y a los pueblos de ...
Mengual Granero, Carles(Universitat Politècnica de València, 2020-07-08)
[ES] A lo largo de este proyecto se realiza el diseño completo de una instalación solar fotovoltaica de 20 MW de corriente alterna situada cerca del río Khan en Ebony, perteneciente a la región de Erongo en Namibia.
En ...
In photovoltaic (PV) double-stage grid-connected inverters a high-frequency DC-DC isolation and voltage step-up stage is commonly used between the panel and the grid-connected inverter. This paper is focused on the modeling ...
Arahal, Manuel R.; Kowal G., Agnieszka; Barrerro, Federico; Castilla, María del Mar(Universitat Politècnica de València, 2018-12-13)
[EN] Control of multi-phase induction machines is evolving with the incorporation of predictive controllers that operate directly with the power converter without modulators. It is realized in discrete-time through an ...
Beltrán, Alberto Miguel; Rumbo Morales, Jesse Yoe; Azcaray, Héctor Ramón; Santiago, Karina; Calixto, Manuela; Sarmiento, Estela(Universitat Politècnica de València, 2019-06-12)
[EN] In this study we present the results obtained in simulation and control of a three-phase induction motor using MATLAB / Simulink. The analysis includes the study of the transient response of the MTI in open loop and ...
[EN] Typically, the control scheme of the active power filter corresponds to a cascade controller, which consists of an outer loop for dc voltage regulation and an inner loop for the tracking of a reference current. Each ...
[EN] Motor failure due to bearing currents is an issue that has drawn an increasing industrial interest over recent years. Bearing currents usually appear in motors operated by variable frequency drives (VFD); these drives ...