How large is the periablational zone after radiofrequency and microwave ablation? Computer-based comparative study of two currently used clinical devices
Fecha
Autores
Prakash, Punit
Faridi, Pegah
Radosevic, Aleksandar
Curto, Sergio
Burdio, Fernando
Directores
Handle
https://riunet.upv.es/handle/10251/161387
Cita bibliográfica
Trujillo Guillen, M.; Prakash, P.; Faridi, P.; Radosevic, A.; Curto, S.; Burdio, F.; Berjano, E. (2020). How large is the periablational zone after radiofrequency and microwave ablation? Computer-based comparative study of two currently used clinical devices. International Journal of Hyperthermia. 37(1):1131-1138. https://doi.org/10.1080/02656736.2020.1823022
Titulación
Resumen
[EN] Purpose To compare the size of the coagulation (CZ) and periablational (PZ) zones created with two commercially available devices in clinical use for radiofrequency (RFA) and microwave ablation (MWA), respectively. Methods Computer models were used to simulate RFA with a 3-cm Cool-tip applicator and MWA with an Amica-Gen applicator. The Arrhenius model was used to compute the damage index (omega). CZ was considered when omega > 4.6 (>99% of damaged cells). Regions with 0.6<omega < 2.1 were considered as the PZ (tissue that has undergone moderate sub-ablative hyperthermia). The ratio of PZ volume to CZ volume (PZ/CZ) was regarded as a measure of performance, since a low value implies achieving a large CZ while keeping the PZ small. Results Ten-min RFA (51 W) created smaller periablational zones than 10-min MWA (11.3 cm(3)vs. 17.2-22.9 cm(3), for 60-100 W MWA, respectively). Prolonging duration from 5 to 10 min increased the PZ in MWA more than in RFA (2.7 cm(3)for RFA vs. 8.3-11.9 cm(3)for 60-100 W MWA, respectively). PZ/CZ for RFA were relatively high (65-69%), regardless of ablation time, while those for MWA were highly dependent on the duration (increase of up to 25% between 5 and 10 min) and on the applied power (smaller values as power was raised, 102% for 60 W vs. 81% for 100 W, both for 10 min). The lowest PZ/CZ across all settings was 56%, obtained with 100 W-5 min MWA. Conclusions Although RFA creates smaller periablational zones than MWA, 100 W-5 min MWA provides the lowest PZ/CZ.
Palabras clave
Microwave ablation, Moderate hyperthermic heating, Periablational zone, Radiofrequency ablation, Thermal ablation, Tumor ablation
ISSN
0265-6736
ISBN
Fuente
International Journal of Hyperthermia
DOI
10.1080/02656736.2020.1823022
Enlaces relacionados
Código de Proyecto
info:eu-repo/grantAgreement/EC/H2020/845645/EU/Optimizing delivery and effectiveness of chemotherapy in breast cancer patients using thermotherapy under image-guidance/
info:eu-repo/grantAgreement/NIH//R01EB028848/
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-094357-B-C21/ES/MODELADO Y EXPERIMENTACION PARA TERAPIAS ABLATIVAS INNOVADORAS/
info:eu-repo/grantAgreement/NIH//R01EB028848/
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-094357-B-C21/ES/MODELADO Y EXPERIMENTACION PARA TERAPIAS ABLATIVAS INNOVADORAS/
Agradecimientos
This work was supported by the Spanish Ministerio de Ciencia, Innovacion y Universidades under "Programa Estatal de I+D+i Orientada a los Retos de la Sociedad", Grant No "RTI2018-094357-B-C21". Punit Prakash acknowledges support from NIH grant R01EB028848. This project has also received funding from the European Union's Horizon 2020 research and innovation programme under the Marie SklodowskaCurie grant agreement No 845645.