On the Influence of Operational and Control Parameters in Thermal Response Testing of Borehole Heat Exchangers

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

On the Influence of Operational and Control Parameters in Thermal Response Testing of Borehole Heat Exchangers

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Badenes Badenes, Borja es_ES
dc.contributor.author Mateo Pla, Miguel Ángel es_ES
dc.contributor.author Lemus Zúñiga, Lenin Guillermo es_ES
dc.contributor.author Saiz Mauleón, María Begoña es_ES
dc.contributor.author Urchueguía Schölzel, Javier Fermín es_ES
dc.date.accessioned 2018-04-14T04:17:26Z
dc.date.available 2018-04-14T04:17:26Z
dc.date.issued 2017 es_ES
dc.identifier.uri http://hdl.handle.net/10251/100418
dc.description.abstract [EN] Thermal response test (TRT) is a common procedure for characterization of ground and borehole thermal properties needed for the design of a shallow geothermal heat pump system. In order to investigate and to develop more accurate and robust procedures for TRT control, modelling, and evaluation in semi-permeable soils with large water content, a pilot borehole heat exchanger was built in the main campus of the Universitat Politècnica de València. The present work shows the results of the experiments performed at the site, analysing the improvements that have been introduced both in the control of the heat injected during TRTs and in the methods to infer the ground thermal parameter. Three models are compared: two based on the infinite-line source theory and one based on the finite-line source scheme. The models were tested under two possible configurations of the equipment, i.e., with and without strict control of injected heat. Our results show the importance of heat injection control for a robust parameter assessment and the existence of additional heat transfer processes that the used models cannot completely characterize and that are related to the presence of significant groundwater flow at the site. In addition, our experience with the current installation and the knowledge about its strengths and weaknesses have allowed us to design a new and more complete test-site to help in the analysis and validation of new ground heat exchanger geometries. es_ES
dc.description.sponsorship This work has received funding from the European Union’s Horizon 2020 Research and Innovation program under grant agreement Nos. (657982) and (727583).
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Energies es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Borehole heat exchanger es_ES
dc.subject Thermal response test (TRT) es_ES
dc.subject Ground-source heat pump es_ES
dc.subject Infinite line-source model es_ES
dc.subject Finite line-source model es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.classification EXPRESION GRAFICA ARQUITECTONICA es_ES
dc.subject.classification ARQUITECTURA Y TECNOLOGIA DE COMPUTADORES es_ES
dc.subject.classification MECANICA DE FLUIDOS es_ES
dc.title On the Influence of Operational and Control Parameters in Thermal Response Testing of Borehole Heat Exchangers es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/en10091328 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/EC/H2020/657982/EU/CHEAP AND EFFICIENT APPLICATION OF RELIABLE GROUND SOURCE HEAT EXCHANGERS AND PUMPS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/EC/H2020/727583/EU/Advanced materials and processes to improve performance and cost-efficiency of Shallow Geothermal systems and Underground Thermal Storage/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Informática de Sistemas y Computadores - Departament d'Informàtica de Sistemes i Computadors es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Expresión Gráfica Arquitectónica - Departament d'Expressió Gràfica Arquitectònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient es_ES
dc.description.bibliographicCitation Badenes Badenes, B.; Mateo Pla, MÁ.; Lemus Zúñiga, LG.; Saiz Mauleón, MB.; Urchueguía Schölzel, JF. (2017). On the Influence of Operational and Control Parameters in Thermal Response Testing of Borehole Heat Exchangers. Energies. 10(9):1-15. https://doi.org/10.3390/en10091328 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/ 10.3390/en10091328 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 15 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 10 es_ES
dc.description.issue 9 es_ES
dc.identifier.eissn 1996-1073 es_ES
dc.relation.pasarela S\342078 es_ES
dc.contributor.funder European Commission


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem