Experimental energetic analysis of the subcooler system in a two-stage refrigeration facility driven by a compound compressor

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

Experimental energetic analysis of the subcooler system in a two-stage refrigeration facility driven by a compound compressor

Show simple item record

Files in this item

dc.contributor.author Torrella Alcaraz, Enrique es_ES
dc.contributor.author Llopis, R. es_ES
dc.contributor.author Cabello, R. es_ES
dc.contributor.author Sanchez, D. es_ES
dc.date.accessioned 2018-04-21T04:24:30Z
dc.date.available 2018-04-21T04:24:30Z
dc.date.issued 2009 es_ES
dc.identifier.issn 1078-9669 es_ES
dc.identifier.uri http://hdl.handle.net/10251/100815
dc.description.abstract [EN] This paper presents a detailed experimental analysis of the energetic effects of using a subcooler system in a two-stage refrigeration facility driven by a compound compressor. The analysis is carried out by comparing the experimental performance of the two-stage cycle working with the subcooler system to the experimental performance of the two-state cycle working without the subcooler system in an evaporating temperature range between -36 degrees C and -21 degrees C and in a condensing temperature range between 31 degrees C and 49 degrees C using R-404A as the working fluid. Experimental results show that the amount of refrigerant used to obtain the subcooling, which is injected between the compression stages, causes an increment in the interstage working pressure, in power consumption, and in the cooling capacity of the cycle. This paper discusses and analyzes these modifications. es_ES
dc.language Inglés es_ES
dc.publisher Taylor & Francis es_ES
dc.relation.ispartof HVAC&R Research es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.title Experimental energetic analysis of the subcooler system in a two-stage refrigeration facility driven by a compound compressor es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1080/10789669.2009.10390852 es_ES
dc.rights.accessRights Cerrado es_ES
dc.description.bibliographicCitation Torrella Alcaraz, E.; Llopis, R.; Cabello, R.; Sanchez, D. (2009). Experimental energetic analysis of the subcooler system in a two-stage refrigeration facility driven by a compound compressor. HVAC&R Research. 15(3):583-596. doi:10.1080/10789669.2009.10390852 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1080/10789669.2009.10390852 es_ES
dc.description.upvformatpinicio 583 es_ES
dc.description.upvformatpfin 596 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 15 es_ES
dc.description.issue 3 es_ES
dc.relation.pasarela S\37420 es_ES