Juste Vidal, BJ.; Miró Herrero, R.; Verdú Martín, GJ.; Díez Domingo, S.; Campayo Esteban, JM. (2011). 6 and 15 MeV photon spectra reconstruction using an unfolding depth dose gradient methodology. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 129-132. doi:10.1109/IEMBS.2011.6089869
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/103491
Title:
|
6 and 15 MeV photon spectra reconstruction using an unfolding depth dose gradient methodology
|
Author:
|
Juste Vidal, Belen Jeanine
Miró Herrero, Rafael
Verdú Martín, Gumersindo Jesús
Diez Domingo, Sergio
Campayo Esteban, Juan Manuel
|
UPV Unit:
|
Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear
|
Issued date:
|
|
Abstract:
|
[EN] An accurate knowledge of the spectral distribution emission is essential for precise dose calculations in radiotherapy treatment planning. Reconstruction of photon spectra emitted by medical accelerators from measured ...[+]
[EN] An accurate knowledge of the spectral distribution emission is essential for precise dose calculations in radiotherapy treatment planning. Reconstruction of photon spectra emitted by medical accelerators from measured depth dose distributions in a water cube is an important tool for commissioning a Monte Carlo treatment planning system. However, the reconstruction problem is an inverse radiation transport function which is poorly conditioned and its solution may become unstable due to small perturbations in the input data. In this paper we present a more stable spectral reconstruction method which can be used to provide an independent confirmation of source models for a given machine without any prior knowledge of the spectral distribution. This technique involves measuring the depth dose curve in a water phantom and applying an unfolding method using Monte Carlo simulated depth dose gradient curves for consecutives mono-energetic beams. We illustrate this theory to calculate a 6 and a 15 MeV photon beam emitted from an Elekta Precise radiotherapy unit using the gradient of depth dose curves in a cube-shaped water tank.
[-]
|
Copyrigths:
|
Cerrado |
Source:
|
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. (issn:
1094-687X
)
|
DOI:
|
10.1109/IEMBS.2011.6089869
|
Publisher:
|
Institute of Electrical and Electronics Engineers
|
Publisher version:
|
http://doi.org/10.1109/IEMBS.2011.6089869
|
Conference name:
|
33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2011)
|
Conference place:
|
Boston, Estados Unidos
|
Conference date:
|
August 30-September 03,2011
|
Type:
|
Artículo
Comunicación en congreso
|