- -

Fundamentos biomecánicos en el diseño de inmovilizador para rehabilitación de fracturas múltiples

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

Fundamentos biomecánicos en el diseño de inmovilizador para rehabilitación de fracturas múltiples

Show simple item record

Files in this item

dc.contributor.author Bula Oyola, Ena Lucía es_ES
dc.date.accessioned 2019-11-15T08:22:16Z
dc.date.available 2019-11-15T08:22:16Z
dc.date.issued 2019-11-13
dc.identifier.isbn 9788490487938
dc.identifier.uri http://hdl.handle.net/10251/131099
dc.description.abstract [ES] Las patologías óseas que afectan a la cintura escapular son comunes y en la mayoría de los casos su recuperación se obtiene a través de tratamiento conservador. Se presenta el caso de paciente femenino de 20 años con politraumatismo por accidente de alta energía. Entre las lesiones se encuentran: una fractura diafisiaria de clavícula derecha con desplazamiento, 11 fracturas de costillas con desplazamiento y luxación escapular. Teniendo en cuenta la inestabilidad toráxica y la incompatibilidad entre la fijación en “8” (Watson-Jones) frente a la disposición de los fragmentos desplazados, se diseñó un inmovilizador basado en la analogía funcional de la cintura escapular y se estableció un sistema de tracciones externos que emulan la acción de los músculos Trapecio, Pectoral Mayor y Deltoides sobre los huesos. El uso continuo del producto durante seis semanas favoreció la consolidación de las fracturas, restituyó la estabilidad de la cintura escapular y el rango de movimiento funcional. La adecuada tracción de los fragmentos de la clavícula y su leve superposición contribuyó a atenuar la discontinuidad en el hombro. Los principales beneficios en el diseño propuesto son: efecto de doble tracción, fijación posterior para mantener la clavícula y omoplatos en posición y bajo condiciones dinámicas, y la posibilidad de generar presión en forma gradual e independiente en puntos prefijados. Estos principios podrían ser aplicables en la rehabilitación de otro tipo de fracturas múltiples. es_ES
dc.description.abstract [EN] Bone pathologies involving the shoulder girdle are common and the rehabilitation is most frequently achieved through conservative treatments. We present the case of 20-year-old female patient with multiple trauma due to high-energy accident. Among the injuries, there was a displaced fracture of the diaphysis of the right clavicle, a displaced fracture of the left humerus, 11 fractures in 8 ribs (2 with displacement) and scapular dyskinesis. Considering the instability of the thorax and the incompatibility between the fixation "8" (Watson-Jones) and the disposition of the displaced fragments, we designed a fracture immobilizer based on the functional analogy of the shoulder girdle. The external traction system developed emulates the action of the Pectoralis Major, Deltoid, Trapezius, Latissimus Dorsi, the upper area of the Oblique of the Abdomen and Serratus Anterior. The continuous use of the product during six weeks allowed the consolidation of the fractures, restored the stability of the scapular girdle and the range of functional movement. The adequate traction of the fragments of the clavicle and its slight overlap contributed to attenuate the discontinuity in the shoulder. The main achievements in the proposed design are: double traction effect; posterior fixation to keep the clavicle and shoulder blades in position under dynamic conditions and the possibility of applying pressure in a gradual and independent way in predetermined points. These principles could be applicable in the rehabilitation of other types of multiple fractures. es_ES
dc.format.extent 13 es_ES
dc.language Español es_ES
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof 11º Simposio CEA de Bioingeniería
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Bioingeniería es_ES
dc.subject Interfaces cerebro-máquina es_ES
dc.subject Tecnología es_ES
dc.subject Rehabilitación es_ES
dc.subject Asistencia es_ES
dc.subject Biomecánica es_ES
dc.subject Bioseñales es_ES
dc.subject Robótica es_ES
dc.subject Imagen médica es_ES
dc.subject Sensores es_ES
dc.subject Instrumentación es_ES
dc.subject Modelado es_ES
dc.subject Simulación es_ES
dc.subject Control es_ES
dc.subject Telemedicina es_ES
dc.subject Biomateriales es_ES
dc.subject Transferencia es_ES
dc.subject Experiencia clínica es_ES
dc.title Fundamentos biomecánicos en el diseño de inmovilizador para rehabilitación de fracturas múltiples es_ES
dc.type Capítulo de libro es_ES
dc.type Comunicación en congreso es_ES
dc.identifier.doi 10.4995/CEABioIng.2019.10043
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Bula Oyola, EL. (2019). Fundamentos biomecánicos en el diseño de inmovilizador para rehabilitación de fracturas múltiples. En 11º Simposio CEA de Bioingeniería. Editorial Universitat Politècnica de València. 36-48. https://doi.org/10.4995/CEABioIng.2019.10043 es_ES
dc.description.accrualMethod OCS es_ES
dc.relation.conferencename 11 Simposio CEA de Bioingeniería es_ES
dc.relation.conferencedate Julio 18-19,2019 es_ES
dc.relation.conferenceplace Valencia, Spain es_ES
dc.relation.publisherversion http://ocs.editorial.upv.es/index.php/CEABioIng/CEABioIng/paper/view/10043 es_ES
dc.description.upvformatpinicio 36 es_ES
dc.description.upvformatpfin 48 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.relation.pasarela OCS\10043 es_ES


This item appears in the following Collection(s)

Show simple item record