Ruiz-Tórtola, Á.; Prats-Quílez, F.; Gonzalez-Lucas, D.; Bañuls Polo, M.; Maquieira Catala, A.; Wheeler, G.; Dalmay, T.... (2018). Experimental study of the evanescent-wave photonic sensors response in presence of molecular beacon conformational changes. Journal of Biophotonics. 11(10). https://doi.org/10.1002/jbio.201800030
Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/136756
Title:
|
Experimental study of the evanescent-wave photonic sensors response in presence of molecular beacon conformational changes
|
Author:
|
Ruiz-Tórtola, Ángela
Prats-Quílez, Francisco
Gonzalez-Lucas, Daniel
Bañuls Polo, María-José
Maquieira Catala, Angel
Wheeler, Guy
Dalmay, Tamas
Griol Barres, Amadeu
Hurtado Montañés, Juan
Bohlmann, Helge
Götzen, Reiner
García-Rupérez, Jaime
|
UPV Unit:
|
Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions
Universitat Politècnica de València. Instituto Universitario de Tecnología Nanofotónica - Institut Universitari de Tecnologia Nanofotònica
Universitat Politècnica de València. Departamento de Química - Departament de Química
|
Issued date:
|
|
Abstract:
|
[EN] An experimental study of the influence of the conformational change suffered by molecular beacon (MB) probesupon the biorecognition of nucleic acid target oligonucleotides over evanescent wave photonic sensorsis ...[+]
[EN] An experimental study of the influence of the conformational change suffered by molecular beacon (MB) probesupon the biorecognition of nucleic acid target oligonucleotides over evanescent wave photonic sensorsis reported. To this end, high sensitivity photonic sensors based on silicon photonic bandgap (PBG) structures were used, where the MB probes were immobilized via their 5 termination. Those MBs incorporate a biotin moiety close to their 3 termination in order to selectively bind a streptavidin molecule to them. The different photonic sensing responses obtained toward the target oligonucleotide detection, when the streptavidin molecule was bound to the MB probes or not, demonstrate the conformational change suffered by the MB upon hybridization, which promotes the displacement of the streptavidin molecule away from the surface of the photonic sensing structure.
[-]
|
Subjects:
|
Conformational change
,
Molecular beacon
,
Photonic bandgap
,
Photonic biosensor
,
Silicon photonics
|
Copyrigths:
|
Reconocimiento (by)
|
Source:
|
Journal of Biophotonics. (issn:
1864-063X
)
|
DOI:
|
10.1002/jbio.201800030
|
Publisher:
|
John Wiley & Sons
|
Publisher version:
|
https://doi.org/10.1002/jbio.201800030
|
Project ID:
|
CEE/644242
AEI/CTQ2016-75749-R
|
Thanks:
|
Horizon 2020 Framework Programme, Grant/Award Number: ICT-644242; MINECO, Grant/Award Number: CTQ/2016/75749-R
|
Type:
|
Artículo
|