- -

Validating the Comparison Framework for the Finite Dimensions Model of Concentric Ring Electrodes Using Human Electrocardiogram Data

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Validating the Comparison Framework for the Finite Dimensions Model of Concentric Ring Electrodes Using Human Electrocardiogram Data

Mostrar el registro completo del ítem

Makeyev, O.; Musngi, M.; Moore, L.; Ye Lin, Y.; Prats-Boluda, G.; Garcia-Casado, J. (2019). Validating the Comparison Framework for the Finite Dimensions Model of Concentric Ring Electrodes Using Human Electrocardiogram Data. Applied Sciences. 9(20):1-14. https://doi.org/10.3390/app9204279

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/145414

Ficheros en el ítem

Metadatos del ítem

Título: Validating the Comparison Framework for the Finite Dimensions Model of Concentric Ring Electrodes Using Human Electrocardiogram Data
Autor: Makeyev, Oleksandr Musngi, Mark Moore, Larry Ye Lin, Yiyao Prats-Boluda, Gema Garcia-Casado, Javier
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Fecha difusión:
Resumen:
[EN] While progress has been made in design optimization of concentric ring electrodes maximizing the accuracy of the surface Laplacian estimation, it was based exclusively on the negligible dimensions model of the electrode. ...[+]
Palabras clave: Electrocardiography , Electrophysiology , Biopotentials , Measurement , Wearable sensors , Noninvasive , Concentric ring electrodes , Laplacian , Estimation , Modeling
Derechos de uso: Reconocimiento (by)
Fuente:
Applied Sciences. (eissn: 2076-3417 )
DOI: 10.3390/app9204279
Editorial:
MDPI AG
Versión del editor: https://doi.org/10.3390/app9204279
Código del Proyecto:
info:eu-repo/grantAgreement/NSF//1622481/US/
info:eu-repo/grantAgreement/NSF//1914787/US/
Agradecimientos:
This research was funded by the National Science Foundation (NSF) Division of Human Resource Development (HRD) Tribal Colleges and Universities Program (TCUP), grants number 1622481 and 1914787 to Oleksandr Makeyev. The ...[+]
Tipo: Artículo

References

Bradshaw, L. A., Richards, W. O., & Wikswo, J. P. (2001). Volume conductor effects on the spatial resolution of magnetic fields and electric potentials from gastrointestinal electrical activity. Medical and Biological Engineering and Computing, 39(1), 35-43. doi:10.1007/bf02345264

Besio, W. G., Hongbao Cao, & Peng Zhou. (2008). Application of Tripolar Concentric Electrodes and Prefeature Selection Algorithm for Brain–Computer Interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 16(2), 191-194. doi:10.1109/tnsre.2007.916303

Farina, D., & Cescon, C. (2001). Concentric-ring electrode systems for noninvasive detection of single motor unit activity. IEEE Transactions on Biomedical Engineering, 48(11), 1326-1334. doi:10.1109/10.959328 [+]
Bradshaw, L. A., Richards, W. O., & Wikswo, J. P. (2001). Volume conductor effects on the spatial resolution of magnetic fields and electric potentials from gastrointestinal electrical activity. Medical and Biological Engineering and Computing, 39(1), 35-43. doi:10.1007/bf02345264

Besio, W. G., Hongbao Cao, & Peng Zhou. (2008). Application of Tripolar Concentric Electrodes and Prefeature Selection Algorithm for Brain–Computer Interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 16(2), 191-194. doi:10.1109/tnsre.2007.916303

Farina, D., & Cescon, C. (2001). Concentric-ring electrode systems for noninvasive detection of single motor unit activity. IEEE Transactions on Biomedical Engineering, 48(11), 1326-1334. doi:10.1109/10.959328

McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997). Spatial filter selection for EEG-based communication. Electroencephalography and Clinical Neurophysiology, 103(3), 386-394. doi:10.1016/s0013-4694(97)00022-2

Wu, D., Tsai, H. C., & He, B. (1999). On the Estimation of the Laplacian Electrocardiogram during Ventricular Activation. Annals of Biomedical Engineering, 27(6), 731-745. doi:10.1114/1.224

Hjorth, B. (1975). An on-line transformation of EEG scalp potentials into orthogonal source derivations. Electroencephalography and Clinical Neurophysiology, 39(5), 526-530. doi:10.1016/0013-4694(75)90056-5

MacKay, D. . (1983). On-line source-density computation with a minimum of electrons. Electroencephalography and Clinical Neurophysiology, 56(6), 696-698. doi:10.1016/0013-4694(83)90040-8

Huiskamp, G. (1991). Difference formulas for the surface Laplacian on a triangulated surface. Journal of Computational Physics, 95(2), 477-496. doi:10.1016/0021-9991(91)90286-t

Besio, G., Koka, K., Aakula, R., & Weizhong Dai. (2006). Tri-polar concentric ring electrode development for Laplacian electroencephalography. IEEE Transactions on Biomedical Engineering, 53(5), 926-933. doi:10.1109/tbme.2005.863887

Besio, W., Aakula, R., Koka, K., & Dai, W. (2006). Development of a Tri-polar Concentric Ring Electrode for Acquiring Accurate Laplacian Body Surface Potentials. Annals of Biomedical Engineering, 34(3), 426-435. doi:10.1007/s10439-005-9054-8

Wang, K., Parekh, U., Pailla, T., Garudadri, H., Gilja, V., & Ng, T. N. (2017). Stretchable Dry Electrodes with Concentric Ring Geometry for Enhancing Spatial Resolution in Electrophysiology. Advanced Healthcare Materials, 6(19), 1700552. doi:10.1002/adhm.201700552

Lidón-Roger, J., Prats-Boluda, G., Ye-Lin, Y., Garcia-Casado, J., & Garcia-Breijo, E. (2018). Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology. Sensors, 18(1), 300. doi:10.3390/s18010300

Besio, W. G., Martinez-Juarez, I. E., Makeyev, O., Gaitanis, J. N., Blum, A. S., Fisher, R. S., & Medvedev, A. V. (2014). High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring Electrodes. IEEE Journal of Translational Engineering in Health and Medicine, 2, 1-11. doi:10.1109/jtehm.2014.2332994

Boudria, Y., Feltane, A., & Besio, W. (2014). Significant improvement in one-dimensional cursor control using Laplacian electroencephalography over electroencephalography. Journal of Neural Engineering, 11(3), 035014. doi:10.1088/1741-2560/11/3/035014

Garcia-Casado, J., Zena-Gimenez, V., Prats-Boluda, G., & Ye-Lin, Y. (2013). Enhancement of Non-Invasive Recording of Electroenterogram by Means of a Flexible Array of Concentric Ring Electrodes. Annals of Biomedical Engineering, 42(3), 651-660. doi:10.1007/s10439-013-0935-y

Zena-Giménez, V., Garcia-Casado, J., Ye-Lin, Y., Garcia-Breijo, E., & Prats-Boluda, G. (2018). A Flexible Multiring Concentric Electrode for Non-Invasive Identification of Intestinal Slow Waves. Sensors, 18(2), 396. doi:10.3390/s18020396

Ye-Lin, Y., Alberola-Rubio, J., Prats-boluda, G., Perales, A., Desantes, D., & Garcia-Casado, J. (2014). Feasibility and Analysis of Bipolar Concentric Recording of Electrohysterogram with Flexible Active Electrode. Annals of Biomedical Engineering, 43(4), 968-976. doi:10.1007/s10439-014-1130-5

Prats-Boluda, G., Ye-Lin, Y., Pradas-Novella, F., Garcia-Breijo, E., & Garcia-Casado, J. (2018). Textile Concentric Ring Electrodes: Influence of Position and Electrode Size on Cardiac Activity Monitoring. Journal of Sensors, 2018, 1-9. doi:10.1155/2018/7290867

Wang, Y.-C., Chang, C.-F., Lin, H.-C., Lin, K.-S., Lin, K.-T., Hung, C.-M., & Lin, T.-M. (2010). Functional characterisation of a complex mutation in the α(1,4)galactosyltransferase gene in Taiwanese individuals with p phenotype. Transfusion Medicine, 21(2), 84-89. doi:10.1111/j.1365-3148.2010.01055.x

Makeyev, O., Ding, Q., & Besio, W. G. (2016). Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes. Measurement, 80, 44-52. doi:10.1016/j.measurement.2015.11.017

Makeyev, O., & Besio, W. (2016). Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes. Sensors, 16(6), 858. doi:10.3390/s16060858

Makeyev, O. (2018). Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation. BioMedical Engineering OnLine, 17(1). doi:10.1186/s12938-018-0549-6

Ye-Lin, Y., Bueno-Barrachina, J. M., Prats-boluda, G., Rodriguez de Sanabria, R., & Garcia-Casado, J. (2017). Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode. Measurement, 97, 195-202. doi:10.1016/j.measurement.2016.11.009

Besio, W., & Chen, T. (2007). Tripolar Laplacian electrocardiogram and moment of activation isochronal mapping. Physiological Measurement, 28(5), 515-529. doi:10.1088/0967-3334/28/5/006

Hamilton, P. S., & Tompkins, W. J. (1986). Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database. IEEE Transactions on Biomedical Engineering, BME-33(12), 1157-1165. doi:10.1109/tbme.1986.325695

Prats-Boluda, G., Ye-Lin, Y., Bueno-Barrachina, J., Rodriguez de Sanabria, R., & Garcia-Casado, J. (2016). Towards the clinical use of concentric electrodes in ECG recordings: influence of ring dimensions and electrode position. Measurement Science and Technology, 27(2), 025705. doi:10.1088/0957-0233/27/2/025705

Mittal, S., Movsowitz, C., & Steinberg, J. S. (2011). Ambulatory External Electrocardiographic Monitoring. Journal of the American College of Cardiology, 58(17), 1741-1749. doi:10.1016/j.jacc.2011.07.026

Garcia-Casado, J., Ye-Lin, Y., Prats-Boluda, G., & Makeyev, O. (2019). Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes. Sensors, 19(17), 3780. doi:10.3390/s19173780

Xu, Y., Luo, M., Li, T., & Song, G. (2017). ECG Signal De-noising and Baseline Wander Correction Based on CEEMDAN and Wavelet Threshold. Sensors, 17(12), 2754. doi:10.3390/s17122754

Ortigueira, M. D., Laleg-Kirati, T.-M., & Machado, J. A. T. (2014). Riesz potential versus fractional Laplacian. Journal of Statistical Mechanics: Theory and Experiment, 2014(9), P09032. doi:10.1088/1742-5468/2014/09/p09032

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem