- -

Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: feasibility study on an agar phantom model

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: feasibility study on an agar phantom model

Mostrar el registro completo del ítem

Blasco-Giménez, R.; Lequerica, JL.; Herrero, M.; Hornero, F.; Berjano, E. (2010). Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: feasibility study on an agar phantom model. Physiological Measurement. 31(4):581-594. https://doi.org/10.1088/0967-3334/31/4/009

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/148246

Ficheros en el ítem

Metadatos del ítem

Título: Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: feasibility study on an agar phantom model
Autor: Blasco-Giménez, Ramón Lequerica, Juan L. Herrero, María Hornero, Fernando Berjano, Enrique
Entidad UPV: Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica
Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica
Fecha difusión:
Resumen:
[EN] The aim of this work was to study linear deterministic models to predict tissue temperature during radiofrequency cardiac ablation (RFCA) by measuring magnitudes such as electrode temperature, power and impedance ...[+]
Palabras clave: Agar phantom , Autoregressive modeling , Black-box modeling , Cardiac ablation , Catheter ablation , Non-structured model , Temperature prediction , Radiofrequency ablation , Temperature measurement
Derechos de uso: Reserva de todos los derechos
Fuente:
Physiological Measurement. (issn: 0967-3334 )
DOI: 10.1088/0967-3334/31/4/009
Editorial:
IOP Publishing
Versión del editor: http://doi.org/10.1088/0967-3334/31/4/009
Código del Proyecto:
info:eu-repo/grantAgreement/CSIC//CSIC-20060633/
info:eu-repo/grantAgreement/MICINN//TEC2008-01369/ES/MODELOS COMPUTACIONALES E INVESTIGACION EXPERIMENTAL EN EL ESTUDIO DE TECNICAS QUIRURGICAS DE CALENTAMIENTO DE TEJIDOS BIOLOGICOS MEDIANTE CORRIENTES DE RADIOFRECUENCIA./
Descripción: This is an author-created, un-copyedited versíon of an article published in Physiological Measurement. IOP Publishing Ltd is not responsíble for any errors or omissíons in this versíon of the manuscript or any versíon derived from it. The Versíon of Record is available online at http://doi.org/10.1088/0967-3334/31/4/009
Agradecimientos:
This work was supported by the 'Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica del Ministerio de Educacion y Ciencia' of Spain (TEC200801369/ TEC) and by an R&D contract (CSIC-20060633) ...[+]
Tipo: Artículo

References

Hong Cao, Tungjitkusolmun, S., Young Bin Choy, Jang-Zern Tsai, Vorperian, V. R., & Webster, J. G. (2002). Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation. IEEE Transactions on Biomedical Engineering, 49(3), 247-253. doi:10.1109/10.983459

Hong Cao, Vorperian, V. R., Jang-Zem Tsai, Tungjitkusolmun, S., Eung Je Woo, & Webster, J. G. (2000). Temperature measurement within myocardium during in vitro RF catheter ablation. IEEE Transactions on Biomedical Engineering, 47(11), 1518-1524. doi:10.1109/10.880104

Hamner, C. E., Potter, D. D., Cho, K. R., Lutterman, A., Francischelli, D., Sundt, T. M., & Schaff, H. V. (2005). Irrigated Radiofrequency Ablation With Transmurality Feedback Reliably Produces Cox Maze Lesions In Vivo. The Annals of Thoracic Surgery, 80(6), 2263-2270. doi:10.1016/j.athoracsur.2005.06.017 [+]
Hong Cao, Tungjitkusolmun, S., Young Bin Choy, Jang-Zern Tsai, Vorperian, V. R., & Webster, J. G. (2002). Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation. IEEE Transactions on Biomedical Engineering, 49(3), 247-253. doi:10.1109/10.983459

Hong Cao, Vorperian, V. R., Jang-Zem Tsai, Tungjitkusolmun, S., Eung Je Woo, & Webster, J. G. (2000). Temperature measurement within myocardium during in vitro RF catheter ablation. IEEE Transactions on Biomedical Engineering, 47(11), 1518-1524. doi:10.1109/10.880104

Hamner, C. E., Potter, D. D., Cho, K. R., Lutterman, A., Francischelli, D., Sundt, T. M., & Schaff, H. V. (2005). Irrigated Radiofrequency Ablation With Transmurality Feedback Reliably Produces Cox Maze Lesions In Vivo. The Annals of Thoracic Surgery, 80(6), 2263-2270. doi:10.1016/j.athoracsur.2005.06.017

HARTUNG, W. M., BURTON, M. E., DEAM, A. G., WALTER, P. F., McTEAGUE, K., & LANGBERG, J. J. (1995). Estimation of Temperature During Radiofrequency Catheter Ablation Using Impedance Measurements. Pacing and Clinical Electrophysiology, 18(11), 2017-2021. doi:10.1111/j.1540-8159.1995.tb03862.x

Ding Sheng He, Bosnos, M., Mays, M. Z., & Marcus, F. (2003). Assessment of myocardial lesion size during in vitro radio frequency catheter ablation. IEEE Transactions on Biomedical Engineering, 50(6), 768-776. doi:10.1109/tbme.2003.812161

KO, W.-C., HUANG, S. K. S., LIN, J.-L., SHAU, W.-Y., LAI, L.-P., & CHEN, P. H. (2001). New Method for Predicting Efficiency of Heating by Measuring Bioimpedance During Radiofrequency Catheter Ablation in Humans. Journal of Cardiovascular Electrophysiology, 12(7), 819-823. doi:10.1046/j.1540-8167.2001.00819.x

Labonte, S. (1994). Numerical model for radio-frequency ablation of the endocardium and its experimental validation. IEEE Transactions on Biomedical Engineering, 41(2), 108-115. doi:10.1109/10.284921

Lai, Y.-C., Choy, Y. B., Haemmerich, D., Vorperian, V. R., & Webster, J. G. (2004). Lesion Size Estimator of Cardiac Radiofrequency Ablation at Different Common Locations With Different Tip Temperatures. IEEE Transactions on Biomedical Engineering, 51(10), 1859-1864. doi:10.1109/tbme.2004.831529

Lequerica, J. L., Berjano, E. J., Herrero, M., Melecio, L., & Hornero, F. (2008). A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom. Physics in Medicine and Biology, 53(4), N25-N34. doi:10.1088/0031-9155/53/4/n01

Mattingly, M., Bailey, E. A., Dutton, A. W., Roemer, R. B., & Devasia, S. (1998). Reduced-order modeling for hyperthermia: an extended balanced-realization-based approach. IEEE Transactions on Biomedical Engineering, 45(9), 1154-1162. doi:10.1109/10.709559

PILCHER, T. A., SANFORD, A. L., SAUL, J. P., & HAEMMERICH, D. (2006). Convective Cooling Effect on Cooled-Tip Catheter Compared to Large-Tip Catheter Radiofrequency Ablation. Pacing and Clinical Electrophysiology, 29(12), 1368-1374. doi:10.1111/j.1540-8159.2006.00549.x

Rodríguez, I., Lequerica, J. L., Berjano, E. J., Herrero, M., & Hornero, F. (2007). Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom model. Physiological Measurement, 28(5), 453-463. doi:10.1088/0967-3334/28/5/001

SCHUMACHER, B., EICK, O., WITTKAMPF, F., PEZOLD, C., TEBBENJOHANNS, J., JUNG, W., & LUDERITZ, B. (1999). Temperature Response Following Nontraumatic Low Power Radiofrequency Application. Pacing and Clinical Electrophysiology, 22(2), 339-343. doi:10.1111/j.1540-8159.1999.tb00448.x

Teixeira, C. A., Ruano, A. E., Ruano, M. G., Pereira, W. C. A., & Negreira, C. (2006). Non-invasive temperature prediction of in vitro therapeutic ultrasound signals using neural networks. Medical & Biological Engineering & Computing, 44(1-2), 111-116. doi:10.1007/s11517-005-0004-2

Teixeira, C. A., Ruano, M. G., Ruano, A. E., & Pereira, W. C. A. (2008). A Soft-Computing Methodology for Noninvasive Time-Spatial Temperature Estimation. IEEE Transactions on Biomedical Engineering, 55(2), 572-580. doi:10.1109/tbme.2007.901029

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem