Diseño de un protocolo para la determinación de biomarcadores para el cálculo de la fibrosis, esteatosis y sobrecarga de hierro hepático mediante análisis de imagen por resonancia magnética

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Diseño de un protocolo para la determinación de biomarcadores para el cálculo de la fibrosis, esteatosis y sobrecarga de hierro hepático mediante análisis de imagen por resonancia magnética

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Moratal Pérez, David es_ES
dc.contributor.advisor Santabárbara Gómez, José Manuel es_ES
dc.contributor.advisor Romero Martín, Juan Antonio es_ES
dc.contributor.author Meneses Felipe, Alba es_ES
dc.date.accessioned 2020-07-24T15:38:38Z
dc.date.available 2020-07-24T15:38:38Z
dc.date.created 2020-07-08
dc.date.issued 2020-07-24 es_ES
dc.identifier.uri http://hdl.handle.net/10251/148646
dc.description.abstract [ES] Las enfermedades hepáticas desde sus inicios han centrado su diagnóstico en la biopsia hepática consagrada como la prueba de referencia de diagnóstico médico para el estudio del hígado de forma directa mediante la invasión en el órgano. Los antagonistas de la biopsia hepática son las técnicas indirectas como los marcadores serológicos y las técnicas no invasivas basadas en imagen médica que emplean el fenómeno de los ultrasonidos, la resonancia magnética nuclear y los rayos X. El enfoque de la medicina hacia técnicas mínimamente invasivas como la resonancia magnética se fundamenta en el estudio de biomarcadores que permitan, una vez que sean evaluados, confirmar el diagnóstico de la fibrosis, esteatosis y sobrecarga de hierro sobre imágenes de resonancia magnética. La fibrosis se ha valorado con mapas T1 que previamente han sido calibrados con fantomas de albúmina, en la esteatosis se ha empleado la técnica Dixon potenciada en T1 que se basa en el desplazamiento químico de los protones del agua y de la grasa para el cálculo de la fracción de grasa hepática y en la sobrecarga de hierro se ha estimado la relajación de T2* que se correlaciona con las concentraciones de hierro en la secuencia multieco potenciada en T1. El protocolo de adquisición consta finalmente de 4 secuencias de resonancia y se ha llevado a cabo en el equipo de resonancia MAGNETOM VIDA 3T de Siemens Healthineers sobre un conjunto de pacientes cuyos datos han sido proporcionados por la empresa ASCIRES Grupo Biomédico. El análisis de los biomarcadores en el procesado de las imágenes médicas se ha realizado con las herramientas software RadiAnt DICOM Viewer para la fibrosis y la esteatosis y MRQuantif para la sobrecarga de hierro. es_ES
dc.description.abstract [EN] Liver diseases since their beginnings have focused their diagnosis on liver biopsy, which has been established as the medical diagnostic reference test for the study of the liver directly through the organ. The antagonists of liver biopsy are indirect techniques such as serological markers and non-invasive techniques based on medical imaging that employ ultrasounds, MRI and X-rays. The approach of medicine to minimally invasive techniques such as MRI is based on the study of biomarkers that allow, once they are evaluated, to confirm the diagnosis of fibrosis, steatosis and iron overload on magnetic resonance imaging. The study of these biological indicators focuses on defining the magnetic resonance sequences that make up an acquisition protocol for the determination of fibrosis, steatosis and iron overload. Fibrosis has been evaluated with T1 maps that have been previously calibrated with albumin phantoms. In steatosis, the T1-weighted Dixon technique has been used, which is based on the chemical displacement of protons in water and fat to calculate the liver fat fraction, and in the iron overload the T2* relaxation has been estimated, which correlates with the iron concentrations in the T1-weighted multiecho sequence. The acquisition protocol finally consists of 4 resonance sequences and it has been carried out in the Siemens Healthineers MAGNETOM VIDA 3T MRI scanner on a set of patients whose data has been provided by the company ASCIRES Grupo Biomédico. The analysis of biomarkers in the processing of medical images has been carried out with the software tools RadiAnt DICOM Viewer for fibrosis and steatosis and MRQuantif for iron overload. es_ES
dc.format.extent 77 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Resonancia magnética es_ES
dc.subject Biomarcadores es_ES
dc.subject Imágenes médicas es_ES
dc.subject Secuencias es_ES
dc.subject Protocolo es_ES
dc.subject Fibrosis es_ES
dc.subject Esteatosis es_ES
dc.subject Sobrecarga de hierro es_ES
dc.subject Calibración es_ES
dc.subject Fantomas es_ES
dc.subject Albúmina. es_ES
dc.subject Magnetic resonance imaging es_ES
dc.subject Biomarkers es_ES
dc.subject Medical imaging es_ES
dc.subject Sequences es_ES
dc.subject Protocol es_ES
dc.subject Steatosis es_ES
dc.subject Iron overload es_ES
dc.subject Calibration es_ES
dc.subject Phantoms es_ES
dc.subject Albumin. es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Diseño de un protocolo para la determinación de biomarcadores para el cálculo de la fibrosis, esteatosis y sobrecarga de hierro hepático mediante análisis de imagen por resonancia magnética es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Meneses Felipe, A. (2020). Diseño de un protocolo para la determinación de biomarcadores para el cálculo de la fibrosis, esteatosis y sobrecarga de hierro hepático mediante análisis de imagen por resonancia magnética. http://hdl.handle.net/10251/148646 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\128202 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem