- -

Caracterización de la respuesta mioeléctrica uterina en inducciones mecánicas del parto mediante registros electrohisterográficos

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Caracterización de la respuesta mioeléctrica uterina en inducciones mecánicas del parto mediante registros electrohisterográficos

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Prats Boluda, Gema es_ES
dc.contributor.advisor Ye Lin, Yiyao es_ES
dc.contributor.advisor Díaz Martínez, María del Alba es_ES
dc.contributor.author Sierra García, Ana es_ES
dc.date.accessioned 2020-09-15T11:52:07Z
dc.date.available 2020-09-15T11:52:07Z
dc.date.created 2020-07-09
dc.date.issued 2020-09-15 es_ES
dc.identifier.uri http://hdl.handle.net/10251/150098
dc.description.abstract [ES] La inducción del parto es una práctica clínica habitual en obstetricia que alcanza el 20 % de todos los partos en los países desarrollados. Con ella se pretende finalizar la gestación y desencadenar un parto vaginal estimulando las contracciones uterinas mediante el uso de agentes mecánicos o farmacológicos. En ocasiones no se consigue y es necesario practicar una cesárea, aumentando los riesgos materno-fetales y los costes correspondientes. El presente trabajo final de grado pretende caracterizar y analizar la respuesta mioeléctrica uterina mediante la monitorización del electrohisterograma en superficie (EHG) en mujeres inducidas mecánicamente con sonda Foley o Cook. Se ha partido de una base de datos de registros propia del grupo de investigación dónde se ha desarrollado el TFG, con registros de EHG desde 30 minutos antes de la colocación de la sonda hasta al menos 4 h tras su colocación. Cada registro se ha preprocesado, se han identificado las contracciones (EHG-Bursts) y se han caracterizado mediante el cómputo de parámetros temporales, espectrales y de no linealidad, analizando la evolución de estos parámetros en ventanas de 30 minutos. Los resultados de los registros de mujeres que han alcanzado periodo activo de parto muestran, un aumento de la amplitud y del número de contracciones y una disminución en su duración. Los parámetros espectrales no han mostrado evolución. Con respecto a los parámetros no lineales, se muestran tendencias erráticas. Los resultados son similares independientemente del tipo de sonda utilizada, aunque en general las mujeres inducidas con sonda Cook presentan una respuesta más tardía en la evolución de los parámetros que las inducidas con sonda Foley. es_ES
dc.description.abstract [EN] Labor induction is a common clinical practice in obstetrics that reaches 20 % of all births in developed countries. The intention of that is to end the pregnancy and trigger a vaginal delivery by stimulating uterine contractions using mechanical or pharmacological agents. Sometimes it is not possible, and a caesarean section is necessary which increase the mother¿s and fetus¿ risks and the corresponding costs. The present final degree project aims to characterize and analyse the uterine myoelectric response by monitoring the surface electrohysterogram (EHG) in mechanically induced women with the Foley or Cook catheter. It begins from a database of records belonging to the research group where the TFG has been developed, with EHG records from 30 minutes before the placement of the catheter to at least 4 h after its placement. Each record has been preprocessed, contractions have been identified (EHG-Bursts) and have been characterize by computing temporal, spectral and non-linear parameters, analysing the evolution of these parameters in 30-minute windows. The results of the registries of women who have reached the active period of labor show, an increase in the amplitude and number of contractions and a decrease in their duration. Spectral parameters have shown no evolution. Regarding nonlinear parameters, erratic trends are shown. The results are similar regardless of type of the catheter, although in general the women induced with the Cook probe show a later response in the evolution of the parameters than those induced with the Foley probe. es_ES
dc.format.extent 78 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Inducción mecánica es_ES
dc.subject Cook es_ES
dc.subject Foley es_ES
dc.subject Parto es_ES
dc.subject Periodo Activo de Parto es_ES
dc.subject EHG es_ES
dc.subject Contracción uterina. es_ES
dc.subject Mechanical Labour Induction es_ES
dc.subject Birth es_ES
dc.subject Active period of labor es_ES
dc.subject Uterine contraction es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.subject.other Grado en Ingeniería Biomédica-Grau en Enginyeria Biomèdica es_ES
dc.title Caracterización de la respuesta mioeléctrica uterina en inducciones mecánicas del parto mediante registros electrohisterográficos es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Sierra García, A. (2020). Caracterización de la respuesta mioeléctrica uterina en inducciones mecánicas del parto mediante registros electrohisterográficos. http://hdl.handle.net/10251/150098 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\128157 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem