Characterization of a preclinical PET insert in a 7 tesla MRI scanner: beyond NEMA testing

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Characterization of a preclinical PET insert in a 7 tesla MRI scanner: beyond NEMA testing

Mostrar el registro completo del ítem

Gsell, W.; Molinos, C.; Correcher, C.; Belderbos, S.; Wouters, J.; Junge, S.; Heidenreich, M.... (2020). Characterization of a preclinical PET insert in a 7 tesla MRI scanner: beyond NEMA testing. Physics in Medicine and Biology. 65(24):1-16. https://doi.org/10.1088/1361-6560/aba08c

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/166819

Ficheros en el ítem

Metadatos del ítem

Título: Characterization of a preclinical PET insert in a 7 tesla MRI scanner: beyond NEMA testing
Autor: Gsell, Willy Molinos, Cesar Correcher, Carlos Belderbos, Sarah Wouters, Jens Junge, Sven Heidenreich, Michael Vande Velde, Greetje Rezaei, Ahmadreza Nuyts, Johan Cawthorne, Christopher Cleeren, Frederik Nannan, Lise Deroose, Christophe M. Himmelreich, Uwe González Martínez, Antonio Javier
Entidad UPV: Universitat Politècnica de València. Instituto de Instrumentación para Imagen Molecular - Institut d'Instrumentació per a Imatge Molecular
Fecha difusión:
Resumen:
[EN] This study evaluates the performance of the Bruker positron emission tomograph (PET) insert combined with a BioSpec 70/30 USR magnetic resonance imaging (MRI) scanner using the manufacturer acceptance protocol and the ...[+]
Palabras clave: Preclinical , PET-insert , MRI , Performances , Imaging
Derechos de uso: Reconocimiento - No comercial - Sin obra derivada (by-nc-nd)
Fuente:
Physics in Medicine and Biology. (issn: 0031-9155 )
DOI: 10.1088/1361-6560/aba08c
Editorial:
IOP Publishing
Versión del editor: https://doi.org/10.1088/1361-6560/aba08c
Código del Proyecto:
info:eu-repo/grantAgreement/EC/FP7/321529/EU/Coordination of European funding for infectious diseases research/
info:eu-repo/grantAgreement/Stichting Tegen Kanker//2015-145/
info:eu-repo/grantAgreement/EC/H2020/686009/EU/PROMOTING ACTIVE AGEING: FUNCTIONAL NANOSTRUCTURES FOR ALZHEIMER’S DISEASE AT ULTRA-EARLY STAGES./
info:eu-repo/grantAgreement/Hercules Foundation//AKUL%2F13%2F029/
Agradecimientos:
We acknowledge the KU Leuven core facility, Molecular Small Animal Imaging Center (MoSAIC), for their support with obtaining scientific data presented in this paper. This work was supported by Stichting tegen Kanker ...[+]
Tipo: Artículo

References

Balezeau, F., Eliat, P.-A., Cayamo, A. B., & Saint-Jalmes, H. (2011). Mapping of low flip angles in magnetic resonance. Physics in Medicine and Biology, 56(20), 6635-6647. doi:10.1088/0031-9155/56/20/008

Benlloch, J. M., González, A. J., Pani, R., Preziosi, E., Jackson, C., Murphy, J., … Schwaiger, M. (2018). The MINDVIEW project: First results. European Psychiatry, 50, 21-27. doi:10.1016/j.eurpsy.2018.01.002

Cal-Gonzalez, J., Rausch, I., Shiyam Sundar, L. K., Lassen, M. L., Muzik, O., Moser, E., … Beyer, T. (2018). Hybrid Imaging: Instrumentation and Data Processing. Frontiers in Physics, 6. doi:10.3389/fphy.2018.00047 [+]
Balezeau, F., Eliat, P.-A., Cayamo, A. B., & Saint-Jalmes, H. (2011). Mapping of low flip angles in magnetic resonance. Physics in Medicine and Biology, 56(20), 6635-6647. doi:10.1088/0031-9155/56/20/008

Benlloch, J. M., González, A. J., Pani, R., Preziosi, E., Jackson, C., Murphy, J., … Schwaiger, M. (2018). The MINDVIEW project: First results. European Psychiatry, 50, 21-27. doi:10.1016/j.eurpsy.2018.01.002

Cal-Gonzalez, J., Rausch, I., Shiyam Sundar, L. K., Lassen, M. L., Muzik, O., Moser, E., … Beyer, T. (2018). Hybrid Imaging: Instrumentation and Data Processing. Frontiers in Physics, 6. doi:10.3389/fphy.2018.00047

Clark, D. P., & Badea, C. T. (2014). Micro-CT of rodents: State-of-the-art and future perspectives. Physica Medica, 30(6), 619-634. doi:10.1016/j.ejmp.2014.05.011

Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., … Schwaiger, M. (2012). First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses. Journal of Nuclear Medicine, 53(6), 845-855. doi:10.2967/jnumed.111.098608

Gonzalez, A. J., Aguilar, A., Conde, P., Hernandez, L., Moliner, L., Vidal, L. F., … Benlloch, J. M. (2016). A PET Design Based on SiPM and Monolithic LYSO Crystals: Performance Evaluation. IEEE Transactions on Nuclear Science, 63(5), 2471-2477. doi:10.1109/tns.2016.2522179

Gonzalez, A. J., Pincay, E. J., Canizares, G., Lamprou, E., Sanchez, S., Catret, J. V., … Correcher, C. (2019). Initial Results of the MINDView PET Insert Inside the 3T mMR. IEEE Transactions on Radiation and Plasma Medical Sciences, 3(3), 343-351. doi:10.1109/trpms.2018.2866899

Grant, A. M., Lee, B. J., Chang, C.-M., & Levin, C. S. (2017). Simultaneous PET/MR imaging with a radio frequency-penetrable PET insert. Medical Physics, 44(1), 112-120. doi:10.1002/mp.12031

Habte, F., Ren, G., Doyle, T. C., Liu, H., Cheng, Z., & Paik, D. S. (2013). Impact of a Multiple Mice Holder on Quantitation of High-Throughput MicroPET Imaging With and Without Ct Attenuation Correction. Molecular Imaging and Biology, 15(5), 569-575. doi:10.1007/s11307-012-0602-y

Hammer, B. E., Christensen, N. L., & Heil, B. G. (1994). Use of a magnetic field to increase the spatial resolution of positron emission tomography. Medical Physics, 21(12), 1917-1920. doi:10.1118/1.597178

Jadvar, H., & Colletti, P. M. (2014). Competitive advantage of PET/MRI. European Journal of Radiology, 83(1), 84-94. doi:10.1016/j.ejrad.2013.05.028

Judenhofer, M. S., Catana, C., Swann, B. K., Siegel, S. B., Jung, W.-I., Nutt, R. E., … Pichler, B. J. (2007). PET/MR Images Acquired with a Compact MR-compatible PET Detector in a 7-T Magnet. Radiology, 244(3), 807-814. doi:10.1148/radiol.2443061756

Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998). Attenuation correction for a combined 3D PET/CT scanner. Medical Physics, 25(10), 2046-2053. doi:10.1118/1.598392

Ko, G. B., Yoon, H. S., Kim, K. Y., Lee, M. S., Yang, B. Y., Jeong, J. M., … Lee, J. S. (2016). Simultaneous Multiparametric PET/MRI with Silicon Photomultiplier PET and Ultra-High-Field MRI for Small-Animal Imaging. Journal of Nuclear Medicine, 57(8), 1309-1315. doi:10.2967/jnumed.115.170019

Lee, B. J., Grant, A. M., Chang, C.-M., Watkins, R. D., Glover, G. H., & Levin, C. S. (2018). MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRI. IEEE Transactions on Medical Imaging, 37(9), 2060-2069. doi:10.1109/tmi.2018.2815620

Loening, A. M., & Gambhir, S. S. (2003). AMIDE: A Free Software Tool for Multimodality Medical Image Analysis. Molecular Imaging, 2(3), 131-137. doi:10.1162/153535003322556877

Mannheim, J. G., Schmid, A. M., Schwenck, J., Katiyar, P., Herfert, K., Pichler, B. J., & Disselhorst, J. A. (2018). PET/MRI Hybrid Systems. Seminars in Nuclear Medicine, 48(4), 332-347. doi:10.1053/j.semnuclmed.2018.02.011

Maramraju, S. H., Smith, S. D., Junnarkar, S. S., Schulz, D., Stoll, S., Ravindranath, B., … Schlyer, D. J. (2011). Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI. Physics in Medicine and Biology, 56(8), 2459-2480. doi:10.1088/0031-9155/56/8/009

Molinos, C., Sasser, T., Salmon, P., Gsell, W., Viertl, D., Massey, J. C., … Heidenreich, M. (2019). Low-Dose Imaging in a New Preclinical Total-Body PET/CT Scanner. Frontiers in Medicine, 6. doi:10.3389/fmed.2019.00088

Nagy, K., Tóth, M., Major, P., Patay, G., Egri, G., Häggkvist, J., … Gulyás, B. (2013). Performance Evaluation of the Small-Animal nanoScan PET/MRI System. Journal of Nuclear Medicine, 54(10), 1825-1832. doi:10.2967/jnumed.112.119065

Nanni, C., & Torigian, D. A. (2008). Applications of Small Animal Imaging with PET, PET/CT, and PET/MR Imaging. PET Clinics, 3(3), 243-250. doi:10.1016/j.cpet.2009.01.002

Omidvari, N., Cabello, J., Topping, G., Schneider, F. R., Paul, S., Schwaiger, M., & Ziegler, S. I. (2017). PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner. Physics in Medicine & Biology, 62(22), 8671-8692. doi:10.1088/1361-6560/aa910d

Omidvari, N., Topping, G., Cabello, J., Paul, S., Schwaiger, M., & Ziegler, S. I. (2018). MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system. Physics in Medicine & Biology, 63(9), 095002. doi:10.1088/1361-6560/aab9d1

Raylman, R. R., Majewski, S., Lemieux, S. K., Velan, S. S., Kross, B., Popov, V., … Marano, G. D. (2006). Simultaneous MRI and PET imaging of a rat brain. Physics in Medicine and Biology, 51(24), 6371-6379. doi:10.1088/0031-9155/51/24/006

Roncali, E., & Cherry, S. R. (2011). Application of Silicon Photomultipliers to Positron Emission Tomography. Annals of Biomedical Engineering, 39(4), 1358-1377. doi:10.1007/s10439-011-0266-9

Schug, D., Lerche, C., Weissler, B., Gebhardt, P., Goldschmidt, B., Wehner, J., … Schulz, V. (2016). Initial PET performance evaluation of a preclinical insert for PET/MRI with digital SiPM technology. Physics in Medicine and Biology, 61(7), 2851-2878. doi:10.1088/0031-9155/61/7/2851

Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K. (1997). Simultaneous PET and MR imaging. Physics in Medicine and Biology, 42(10), 1965-1970. doi:10.1088/0031-9155/42/10/010

Steinert, H. C., & von Schulthess, G. K. (2002). Initial clinical experience using a new integrated in-line PET/CT system. The British Journal of Radiology, 75(suppl_9), S36-S38. doi:10.1259/bjr.75.suppl_9.750036

Stortz, G., Thiessen, J. D., Bishop, D., Khan, M. S., Kozlowski, P., Retière, F., … Sossi, V. (2017). Performance of a PET Insert for High-Resolution Small-Animal PET/MRI at 7 Tesla. Journal of Nuclear Medicine, 59(3), 536-542. doi:10.2967/jnumed.116.187666

Townsend, D. W. (2008). Combined Positron Emission Tomography–Computed Tomography: The Historical Perspective. Seminars in Ultrasound, CT and MRI, 29(4), 232-235. doi:10.1053/j.sult.2008.05.006

Vandenberghe, S., & Marsden, P. K. (2015). PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging. Physics in Medicine and Biology, 60(4), R115-R154. doi:10.1088/0031-9155/60/4/r115

Vaquero, J. J., & Kinahan, P. (2015). Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems. Annual Review of Biomedical Engineering, 17(1), 385-414. doi:10.1146/annurev-bioeng-071114-040723

Von Schulthess, G. K., & Schlemmer, H.-P. W. (2008). A look ahead: PET/MR versus PET/CT. European Journal of Nuclear Medicine and Molecular Imaging, 36(S1), 3-9. doi:10.1007/s00259-008-0940-9

Wehner, J., Weissler, B., Dueppenbecker, P. M., Gebhardt, P., Goldschmidt, B., Schug, D., … Schulz, V. (2015). MR-compatibility assessment of the first preclinical PET-MRI insert equipped with digital silicon photomultipliers. Physics in Medicine and Biology, 60(6), 2231-2255. doi:10.1088/0031-9155/60/6/2231

Wehrl, H. F., Judenhofer, M. S., Thielscher, A., Martirosian, P., Schick, F., & Pichler, B. J. (2010). Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T. Magnetic Resonance in Medicine, 65(1), 269-279. doi:10.1002/mrm.22591

Yamamoto, S., Imaizumi, M., Kanai, Y., Tatsumi, M., Aoki, M., Sugiyama, E., … Hatazawa, J. (2010). Design and performance from an integrated PET/MRI system for small animals. Annals of Nuclear Medicine, 24(2), 89-98. doi:10.1007/s12149-009-0333-6

Yamamoto, S., Watabe, T., Watabe, H., Aoki, M., Sugiyama, E., Imaizumi, M., … Hatazawa, J. (2011). Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system. Physics in Medicine and Biology, 57(2), N1-N13. doi:10.1088/0031-9155/57/2/n1

Zaidi, H., Montandon, M.-L., & Alavi, A. (2008). The Clinical Role of Fusion Imaging Using PET, CT, and MR Imaging. PET Clinics, 3(3), 275-291. doi:10.1016/j.cpet.2009.03.002

[-]

recommendations

 

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro completo del ítem