Optimización hidraúlica y estudio térmico de un intercambiador geotérmico de geometría experimental mediante técnicas CFD.

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Optimización hidraúlica y estudio térmico de un intercambiador geotérmico de geometría experimental mediante técnicas CFD.

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Mateo Pla, Miguel Ángel es_ES
dc.contributor.advisor Badenes Badenes, Borja es_ES
dc.contributor.author Torres Pons, Alfredo Francisco es_ES
dc.date.accessioned 2021-09-13T08:14:32Z
dc.date.available 2021-09-13T08:14:32Z
dc.date.created 2021-07-27
dc.date.issued 2021-09-13 es_ES
dc.identifier.uri http://hdl.handle.net/10251/172180
dc.description.abstract [ES] La energía geotérmica se presenta como una alternativa sostenible dentro de las energías renovables para la climatización de viviendas o invernaderos. Las instalaciones geotérmicas de pozos verticales, son las más utilizadas en la actualidad, ya que se aprovechan de que la temperatura del subsuelo se mantiene constante a partir de cierta profundidad. El principal inconveniente de este tipo de instalación es el sobre coste derivado de la perforación del suelo para la realización de los pozos. El objetivo de este trabajo es la optimización de la cabeza y del pie de un intercambiador de calor enterrado de geometría experimental de una instalación geotérmica para reducir sus pérdida hidráulicas. Se analizarán tres geometrías basadas en una curva de transición utilizada para el diseño de carreteras llamada clotoide, comprobando su utilidad en el diseño de circuitos hidráulicos. Además si los recursos en términos de tiempo y equipo informático de los que se dispone resultan adecuados, se realizará un estudio de los diferentes parámetros térmicos de dicho intercambiador comparándolos con los de un modelo comercial, esperando obtener mejoras significativas en el rendimiento térmico. Para ello se seguirá la metodología CFD, principalmente mediante el programa comercial ANSYS. Se compararán los resultados de estas simulaciones con los obtenidos en ensayos experimentales realizados en el laboratorio de geotérmica de la UPV. es_ES
dc.description.abstract [EN] Geothermal energy is presented as a sustainable alternative within renewable energies for the air conditioning of homes or greenhouses. Geothermal installations with vertical wells are currently the most widely used, since they take advantage of the fact that the temperature of the subsoil remains constant from a certain depth. The main disadvantage of this type of installation is the extra cost derived from the drilling of the ground for the realization of the wells.\\ The objective of this work is the optimization of the head and foot of a buried heat exchanger of experimental geometry of a geothermal installation in order to reduce its hydraulic losses. Three geometries based on a transition curve used for road design called clotoid will be analyzed, checking its usefulness in the design of hydraulic circuits. In addition, if the resources in terms of time and computer equipment available are adequate, a study of the different thermal parameters of the exchanger will be carried out comparing them with those of a commercial model, hoping to obtain significant improvements in the thermal performance.\\ For this purpose, the CFD methodology will be used, mainly by means of the commercial program ANSYS. The results of these simulations will be compared with those obtained in experimental tests carried out in the geothermal laboratory of the UPV. es_ES
dc.format.extent 109 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Intercambiador de calor enterrrado es_ES
dc.subject Energías renovables es_ES
dc.subject Energía geotérmica es_ES
dc.subject Dinámica de fluidos computacional es_ES
dc.subject Pérdidas hidráulicas es_ES
dc.subject Pozo es_ES
dc.subject Transición energética es_ES
dc.subject Cambio climático es_ES
dc.subject Termofluidodinámica es_ES
dc.subject Buried heat exchanger es_ES
dc.subject Renewable energies es_ES
dc.subject Geothermal energy es_ES
dc.subject Computational fluid dynamics es_ES
dc.subject Hydraulic losses es_ES
dc.subject Well es_ES
dc.subject Energy transition es_ES
dc.subject Climate change es_ES
dc.subject Thermofluidodynamics es_ES
dc.subject.classification ARQUITECTURA Y TECNOLOGIA DE COMPUTADORES es_ES
dc.subject.classification MECANICA DE FLUIDOS es_ES
dc.subject.other Grado en Ingeniería Aeroespacial-Grau en Enginyeria Aeroespacial es_ES
dc.title Optimización hidraúlica y estudio térmico de un intercambiador geotérmico de geometría experimental mediante técnicas CFD. es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Informática de Sistemas y Computadores - Departament d'Informàtica de Sistemes i Computadors es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Torres Pons, AF. (2021). Optimización hidraúlica y estudio térmico de un intercambiador geotérmico de geometría experimental mediante técnicas CFD. Universitat Politècnica de València. http://hdl.handle.net/10251/172180 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\143731 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem