- -

Performance assessment of electrode configurations for the estimation of omnipolar electrograms from high density arrays

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Performance assessment of electrode configurations for the estimation of omnipolar electrograms from high density arrays

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Castells, Francisco es_ES
dc.contributor.author Ruiperez-Campillo, Samuel es_ES
dc.contributor.author Segarra, Izan es_ES
dc.contributor.author Cervigon, Raquel es_ES
dc.contributor.author Casado-Arroyo, Rubén es_ES
dc.contributor.author Merino, José Luis es_ES
dc.contributor.author Millet Roig, José es_ES
dc.date.accessioned 2024-02-09T09:39:53Z
dc.date.available 2024-02-09T09:39:53Z
dc.date.issued 2023-03 es_ES
dc.identifier.issn 0010-4825 es_ES
dc.identifier.uri http://hdl.handle.net/10251/202489
dc.description.abstract [EN] Objective: The aim of this study is to propose a method to reduce the sensitivity of the estimated omnipolar electrogram (oEGM) with respect to the angle of the propagation wavefront. Methods: A novel configuration of cliques taking into account all four electrodes of a squared cell is proposed. To test this approach, simulations of HD grids of cardiac activations at different propagation angles, conduction velocities, interelectrode distance and electrogram waveforms are considered. Results: The proposed approach successfully provided narrower loops (essentially a straight line) of the electrical field described by the bipole pair with respect to the conventional approach. Estimation of the direction of propagation was improved. Additionally, estimated oEGMs presented larger amplitude, and estimations of the local activation times were more accurate. Conclusions: A novel method to improve the estimation of oEGMs in HD grid of electrodes is proposed. This approach is superior to the existing methods and avoids pitfalls not yet resolved. es_ES
dc.description.sponsorship This work was supported by PID2019-109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovacion, Spanish Government) and CIacBERCV CB16/11/00486 (Instituto de Salud Carlos III). We would like express our gratitute to the Rafael del Pino Foundation and La Caixa Foundation for the support and contribution to the academic training of one first author of the manuscript (S. Ruiperez-Campillo). es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Computers in Biology and Medicine es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject High density electrode arrays es_ES
dc.subject Omnipolar electrograms es_ES
dc.subject Signal processing es_ES
dc.subject Robust electrogram estimation es_ES
dc.subject Electrophysiology es_ES
dc.subject Biomedical engineering es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Performance assessment of electrode configurations for the estimation of omnipolar electrograms from high density arrays es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.compbiomed.2023.106604 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2019-109547RB-I00/ES/CUANTIFICACION DEL DETERIORO LOCAL DEL MIOCARDIO MEDIANTE CATETER MULTIELECTRODO GRID ALTA DENSIDAD. IDENTIFICACION DE METRICAS DEL SUSTRATO FIBROTICO RESPONSABLE DE ARRITMIAS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//CB16%2F11%2F00486/ES/ENFERMEDADES CARDIOVASCULARES/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Telecomunicación - Escola Tècnica Superior d'Enginyers de Telecomunicació es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia es_ES
dc.description.bibliographicCitation Castells, F.; Ruiperez-Campillo, S.; Segarra, I.; Cervigon, R.; Casado-Arroyo, R.; Merino, JL.; Millet Roig, J. (2023). Performance assessment of electrode configurations for the estimation of omnipolar electrograms from high density arrays. Computers in Biology and Medicine. 154. https://doi.org/10.1016/j.compbiomed.2023.106604 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.compbiomed.2023.106604 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 154 es_ES
dc.identifier.pmid 36709520 es_ES
dc.relation.pasarela S\481827 es_ES
dc.contributor.funder Instituto de Salud Carlos III es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.subject.ods 03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edades es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem