Mostrar el registro sencillo del ítem
dc.contributor.author | Gutiérrez Rubert, Santiago Carlos | es_ES |
dc.contributor.author | Meseguer Calas, María Desamparados | es_ES |
dc.contributor.author | Estal, R. | |
dc.contributor.author | Folguera, F. | |
dc.contributor.author | Vidal, V. | |
dc.date.accessioned | 2015-06-18T11:54:07Z | |
dc.date.available | 2015-06-18T11:54:07Z | |
dc.date.issued | 2012 | |
dc.identifier.isbn | 978-0-7354-1017-6 | |
dc.identifier.issn | 0094-243X | |
dc.identifier.uri | http://hdl.handle.net/10251/51902 | |
dc.description.abstract | [EN] Fixed partial dentures can be fabricated by means of different materials and with different manufacturing processes. In order to establish possible differences among them, their behaviour, as fatigue life or cement shear bond strength, have to be evaluated. This article presents a modular, economic and robust device to evaluate fixed partial dentures and dental crowns. A base to support the fixed partial dentures and a device to simulate masticatory loads have been developed. The device has got a simple design. It is based on a pneumatic piston, with a pressure regulator to control masticatory loads. On a first stage, only vertical forces have been taking into account. However, the device will allow simulating tangential masticatory loads on the other axis, studying the behaviour of the fixed partial dentures submerged in a solution similar to saliva, changing masticatory load application, etc. with little modifications. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | American Institute of Physics (AIP) | es_ES |
dc.relation.ispartof | AIP Conference Proceedings | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Validation | es_ES |
dc.subject | Laboratory equipment | es_ES |
dc.subject | Testing device | es_ES |
dc.subject | Simulation device | es_ES |
dc.subject | Masticatory force | es_ES |
dc.subject | Fixed partial dentures | es_ES |
dc.subject.classification | INGENIERIA DE LOS PROCESOS DE FABRICACION | es_ES |
dc.title | Development of a device to study fatigue life of fixed partial dentures | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1063/1.4707646 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials | es_ES |
dc.description.bibliographicCitation | Gutiérrez Rubert, SC.; Meseguer Calas, MD.; Estal, R.; Folguera, F.; Vidal, V. (2012). Development of a device to study fatigue life of fixed partial dentures. AIP Conference Proceedings. 1431:877-884. doi:10.1063/1.4707646 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1063/1.4707646 | es_ES |
dc.description.upvformatpinicio | 877 | es_ES |
dc.description.upvformatpfin | 884 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 1431 | es_ES |
dc.relation.senia | 233303 | |
dc.identifier.eissn | 1551-7616 |