Mostrar el registro sencillo del ítem
dc.contributor.author | García Taengua, Emilio José | es_ES |
dc.contributor.author | Martí Vargas, José Rocío | es_ES |
dc.contributor.author | Serna Ros, Pedro | es_ES |
dc.date.accessioned | 2015-09-25T12:29:48Z | |
dc.date.available | 2015-09-25T12:29:48Z | |
dc.date.issued | 2014-02 | |
dc.identifier.issn | 0039-2103 | |
dc.identifier.uri | http://hdl.handle.net/10251/55123 | |
dc.description.abstract | This paper presents the results of an experimental research dealing with bond strength as a parameter for concrete quality control. To this end, a low-cost testing technique has been developed: the Bottle Bond Test (BBT). Specimens for the BBT are produced by casting concrete into empty plastic bottles (used as moulds) with a reinforcing bar longitudinally centred. The result is a bottle-shaped concrete specimen with an embedded rebar, which is pulled out to determine bond strength. Different parameters related to this test setup modify bond strength: their effect has been analyzed. An equation to relate the obtained bond strength values to concrete compressive strength is presented. This equation has been validated with real production data from a readymix concrete plant. Its accuracy and therefore the feasibility of BBT for concrete quality control have been verified. Therefore, the BBT can be an alternative to conventional concrete quality based on uniaxial compression tests. | es_ES |
dc.description.sponsorship | The authors of this work wish to thank both the Research Bureau of the Spanish Ministry of Science and Innovation and the 'Plan E' programme for the funding of the project 'BIA 2009-12722', this research being a part thereof. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | WILEY-BLACKWELL | es_ES |
dc.relation.ispartof | Strain | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Bond | es_ES |
dc.subject | compressive strength | es_ES |
dc.subject | concrete | es_ES |
dc.subject | Quality Control | es_ES |
dc.subject | test | es_ES |
dc.subject.classification | INGENIERIA DE LA CONSTRUCCION | es_ES |
dc.title | Bond of Reinforcement in Concrete Applied to Concrete Quality Control: The Bottle Bond Test | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1111/str.12067 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//BIA2009-12722/ES/EL HORMIGON DE FIBRAS DE ACERO COMO SUPERACION DEL HORMIGON TRADICIONAL Y SUS PERSPECTIVAS DE FUTURO/ | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil | es_ES |
dc.description.bibliographicCitation | García Taengua, EJ.; Martí Vargas, JR.; Serna Ros, P. (2014). Bond of Reinforcement in Concrete Applied to Concrete Quality Control: The Bottle Bond Test. Strain. 50(1):57-67. https://doi.org/10.1111/str.12067 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1111/str.12067 | es_ES |
dc.description.upvformatpinicio | 57 | es_ES |
dc.description.upvformatpfin | 67 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 50 | es_ES |
dc.description.issue | 1 | es_ES |
dc.relation.senia | 285237 | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | |
dc.description.references | Cattaneo, S., & Mola, F. (2012). Assessing the Quality Control of Self-Consolidating Concrete Properties. Journal of Construction Engineering and Management, 138(2), 197-205. doi:10.1061/(asce)co.1943-7862.0000410 | es_ES |
dc.description.references | Comité Européen de Normalisation (CEN) 2004 Eurocode 2: design of concrete structures-part 1-1: general rules and rules for buildings European standard EN 1992-1-1:2004:E | es_ES |
dc.description.references | Laungrungrong, B., Mobasher, B., Montgomery, D., & Borror, C. M. (2010). Hybrid Control Charts for Active Control and Monitoring of Concrete Strength. Journal of Materials in Civil Engineering, 22(1), 77-87. doi:10.1061/(asce)0899-1561(2010)22:1(77) | es_ES |
dc.description.references | Mwamila, B. L. M., & Karumuna, B. L. (1999). Semi-prefabrication concrete techniques in developing countries. Building Research & Information, 27(3), 165-182. doi:10.1080/096132199369507 | es_ES |
dc.description.references | Kumaraswamy, M. M., & Shrestha, G. B. (2002). Targeting «technology exchange» for faster organizational and industry development. Building Research & Information, 30(3), 183-195. doi:10.1080/09613210110115216 | es_ES |
dc.description.references | Lorrain , M. Barbosa , M. 2008 Controle de qualidade dos concretos estruturais: ensaio de aderência aço-concreto Revista Concreto 55 60 | es_ES |
dc.description.references | Lorrain , M. Pinto-Barbosa , M. Arnaud , M. 2010 Bond test and on-site structural concrete quality control Proceedings of the 3rd fib International Congress | es_ES |
dc.description.references | International Federation for Structural Concrete 2000 Bond of reinforcement in concrete. State of the art report | es_ES |
dc.description.references | Martí-Vargas, J. R., Fernández-Prada, M. A., Arbeláez, C. A., Serna-Ros, P., & Miguel-Sosa, P. F. (2006). Transfer and Development Lengths of Concentrically Prestressed Concrete. PCI Journal, 51(5), 74-85. doi:10.15554/pcij.09012006.74.85 | es_ES |
dc.description.references | Martí-Vargas, J. R., Caro, L. A., & Serna, P. (2012). Experimental Technique for Measuring the Long-term Transfer Length in Prestressed Concrete. Strain, 49(2), 125-134. doi:10.1111/str.12019 | es_ES |
dc.description.references | Martí-Vargas, J. R., Serna, P., Navarro-Gregori, J., & Bonet, J. L. (2012). Effects of concrete composition on transmission length of prestressing strands. Construction and Building Materials, 27(1), 350-356. doi:10.1016/j.conbuildmat.2011.07.038 | es_ES |
dc.description.references | Martí-Vargas, J. R., Serna, P., Navarro-Gregori, J., & Pallarés, L. (2012). Bond of 13mm prestressing steel strands in pretensioned concrete members. Engineering Structures, 41, 403-412. doi:10.1016/j.engstruct.2012.03.056 | es_ES |
dc.description.references | Do Vale Silva , B. Pinto Barbosa , M. Pinto da Silva , L. Lorrain , M. Dal Bosco , V. I. 2011 Correlaçao entre a tensao última de aderencia e a resistencia do concreto usando ensaio “APULOT”: avaliaçao do efeito de variaçao do cobrimento do concreto ao redor da barra de aço Anais do 53º Congresso Brasileiro do Concreto IBRACON CBC2011 | es_ES |
dc.description.references | European Committee for Standardisation 2011 EN 197-1:2011. Cement-part 1: composition, specifications and conformity criteria for common cements | es_ES |
dc.description.references | European Committee for Standardisation 2005 EN 10080:2005. Steel for the reinforcement of concrete-weldable reinforcing steel-general | es_ES |
dc.description.references | Martí-Vargas, J. R., & Hale, W. M. (2013). Predicting Strand Transfer Length in Pretensioned Concrete: Eurocode versus North American Practice. Journal of Bridge Engineering, 18(12), 1270-1280. doi:10.1061/(asce)be.1943-5592.0000456 | es_ES |
dc.description.references | Martí-Vargas, J. R., Serna, P., & Hale, W. M. (2013). Strand bond performance in prestressed concrete accounting for bond slip. Engineering Structures, 51, 236-244. doi:10.1016/j.engstruct.2013.01.023 | es_ES |
dc.description.references | Kleinbaum, D. G., & Klein, M. (2010). Logistic Regression. Statistics for Biology and Health. doi:10.1007/978-1-4419-1742-3 | es_ES |
dc.description.references | American Concrete Institute, Committee 214 2011 Report 214R-11. Guide to evaluation of strength test results of concrete | es_ES |