Ficheros en el ítem

dc.contributor.author Climent, Andreu M. es_ES
dc.contributor.author Atienza, Felipe es_ES
dc.contributor.author Millet Roig, José es_ES
dc.contributor.author Guillem Sánchez, María Salud es_ES
dc.date.accessioned 2016-01-08T13:52:22Z
dc.date.available 2016-01-08T13:52:22Z
dc.date.issued 2011-11
dc.identifier.issn 0140-0118
dc.identifier.uri http://hdl.handle.net/10251/59568
dc.description.abstract The aim of the this study is to describe a methodological architecture for the generation of realistic atrial to atrial activation intervals (AA) during atrial fibrillation (AF), which can be used to investigate the role of the fibrillatory process in the ventricular response during AF. In this study, a methodology for the generation of AA interval series with a desired probability density function and autocorrelation function is presented. The methodology was evaluated on 2000 AA interval series from 20 endocardial recordings. The results showed that synthetic AA series presented the same statistical characteristics as the real AA series, with a correlation higher than 0.94 (P < 0.01) for all measured statistical parameters. In addition, the role of each statistical characteristic of the AA interval series in the ventricular response during AF is examined using a mathematical model of the atrioventricular node. The statistical characteristics of the AA series influenced the position of more probable RR intervals and the shape of the RR histogram, demonstrating the importance of an accurate characterization and generation of AA interval series during AF. The use of the present methodology may help in understanding the role of the atrial fibrillatory process in the ventricular response during AF. es_ES
dc.description.sponsorship This research was supported by Spanish Ministry of Education and Science under TEC2009-13939; the Universitat Politecnica de Valencia through its research initiative program; and the Spanish Society of Cardiology. en_EN
dc.language Inglés es_ES
dc.publisher Springer Verlag (Germany) es_ES
dc.relation.ispartof Medical and Biological Engineering and Computing es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Atrioventricular conduction es_ES
dc.subject Pearson type IV es_ES
dc.subject Rate control es_ES
dc.subject Statistical modeling es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Generation of realistic atrial to atrial interval series during atrial fibrillation es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1007/s11517-011-0823-2
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//TEC2009-13939/ES/Desarrollo De Tecnicas Avanzadas De Analisis Y Caracterizacion De Mapas De Propagacion Para La Ayuda Al Diagnostico Electrocardiografico/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario de Aplicaciones de las Tecnologías de la Información - Institut Universitari d'Aplicacions de les Tecnologies de la Informació es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.description.bibliographicCitation Climent, AM.; Atienza, F.; Millet Roig, J.; Guillem Sánchez, MS. (2011). Generation of realistic atrial to atrial interval series during atrial fibrillation. Medical and Biological Engineering and Computing. 49(11):1261-1268. doi:10.1007/s11517-011-0823-2 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1007/s11517-011-0823-2 es_ES
dc.description.upvformatpinicio 1261 es_ES
dc.description.upvformatpfin 1268 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 49 es_ES
dc.description.issue 11 es_ES
dc.relation.senia 208801 es_ES
dc.contributor.funder Universitat Politècnica de València es_ES
dc.contributor.funder Sociedad Española de Cardiología es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación
dc.description.references Chen S, Nie H, Ayers-Glassey B (2008) Lognormal sum approximation with a variant of type IV Pearson distribution. IEEE Commun Lett 12:630–632 es_ES
dc.description.references Chorro FJ, Kirchhof CJHJ, Brugada J, Allessie MA (1990) Ventricular response during irregular atrial-pacing and atrial-fibrillation. Am J Physiol Heart Circ Physiol 259:H1015–H1021 es_ES
dc.description.references Chorro FJ, Sanchis J, Lopez-Merino V, Such L, Avellana JA, Valentin V (1991) Effects of atrial impulse timing on AV concealed conduction in the rabbit heart. Pacing Clin Electrophysiol 14(5 Pt 1):842–853 es_ES
dc.description.references Climent AM, Guillem MS, Husser D, Castells F, Millet J, Bollmann A (2009) Poincare surface profiles of RR intervals. A novel noninvasive method for the evaluation of preferential AV nodal conduction during atrial fibrillation. IEEE Trans Biomed Eng 56(2):433–442 es_ES
dc.description.references Climent AM, Guillem MS, Husser D, Castells F, Millet J, Bollmann A (2010) Role of the atrial rate as a factor modulating ventricular response during atrial fibrillation. Pacing Clin Electrophysiol 33:1510–1517 es_ES
dc.description.references Climent AM, Guillem MS, Zhang Y, Millet J, Mazgalev T (2011) Functional mathematical model of dual pathway AV nodal conductions. Am J Physiol Heart Circ Physiol 300(4):H1393–H1401 es_ES
dc.description.references Cohen RJ, Berger RD (1983) A quantitative model for the ventricular response during atrial-fibrillation. IEEE Trans Biomed Eng 30:769–781 es_ES
dc.description.references Cover TM, Thomas JA (2006) Elements of information theory. Wiley, New York es_ES
dc.description.references Devroye L (1989) On random variate generation when only moments or Fourier coefficients are known. Math Comput Simul 31:71–89 es_ES
dc.description.references Faes L, Nollo G, Antolini R, Gaita F, Ravelli F (2002) A method for quantifying atrial fibrillation organization based on wave-morphology similarity. IEEE Trans Biomed Eng 49:1504–1513 es_ES
dc.description.references Fuster V, Ryden LE, Cannom DS, Crijns HJ, Curtis AB, Ellenbogen KA, Halperin JL, Le Heuzey JY, Kay GN, Lowe JE, Olsson SB, Prystowsky EN, Tamargo JL, Wann S (2006) ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation. Europace 8:651–745 es_ES
dc.description.references Garrigue S, Mowrey KA, Fahy G, Tchou PJ, Mazgalev TN (1999) Atrioventricular nodal conduction during atrial fibrillation: role of atrial input modification. Circulation 99:2323–2333 es_ES
dc.description.references Garrigue S, Tchou PJ, Mazgalev TN (1999) Role of the differential bombardment of atrial inputs to the atrioventricular node as a factor influencing ventricular rate during high atrial rate. Cardiovasc Res 44:344–355 es_ES
dc.description.references Gerstenfeld EP, Sahakian AV, Swiryn S (1992) Evidence for transient linking of atrial excitation during atrial fibrillation in humans. Circulation 86:375–382 es_ES
dc.description.references Heethaar RM, Denier van der Gon JJ, Meijler FL (1973) Mathematical model of A-V conduction in the rat heart. Cardiovasc Res 7:105–114 es_ES
dc.description.references Heethaar RM, van der Gon JJ, Meijler FL (1973) Interpretation of some properties of A-V conduction with the help of analog simulation. Eur J Cardiol 1:87–93 es_ES
dc.description.references Heinrich J (2004) A guide to the Pearson type IV distribution. http://www-cdf.fnal.gov es_ES
dc.description.references Inada S, Hancox JC, Zhang H, Boyett MR (2009) One-dimensional mathematical model of the atrioventricular node including atrio-nodal, nodal, and nodal-his cells. Biophys J 97:2117–2127 es_ES
dc.description.references Izrailev FM, Krokhin AA, Makarov NM, Usatenko OV (2007) Generation of correlated binary sequences from white noise. Phys Rev E 76:1–4 es_ES
dc.description.references Jorgensen P, Schafer C, Guerra PG, Talajic M, Nattel S, Glass L (2002) A mathematical model of human atrioventricular nodal function incorporating concealed conduction. Bull Math Biol 64:1083–1099 es_ES
dc.description.references Kwan R, Leung C (2007) On the applicability of the Pearson method for approximating distributions in wireless communications. IEEE Trans Commun 55:2065–2069 es_ES
dc.description.references Lian J, Mussig D, Lang V (2006) Computer modeling of ventricular rhythm during atrial fibrillation and ventricular pacing. IEEE Trans Biomed Eng 53:1512–1520 es_ES
dc.description.references Makse HA, Havlin S, Schwartz M, Stanley HE (1996) Method for generating long-range correlations for large systems. Phys Rev E 53:5445–5449 es_ES
dc.description.references Mangin L, Vinet A, Page P, Glass L (2005) Effects of antiarrhythmic drug therapy on atrioventricular nodal function during atrial fibrillation in humans. Europace 7(Suppl 2):71–82 es_ES
dc.description.references Mazgalev TN, Garrigue S, Mowrey KA, Yamanouchi Y, Tchou PJ (1999) Autonomic modification of the atrioventricular node during atrial fibrillation: role in the slowing of ventricular rate. Circulation 99:2806–2814 es_ES
dc.description.references Meijler FL, Jalife J, Beaumont J, Vaidya D (1996) AV nodal function during atrial fibrillation: the role of electrotonic modulation of propagation. J Cardiovasc Electrophysiol 7:843–861 es_ES
dc.description.references Meurling CJ, Waktare JE, Holmqvist F, Hedman A, Camm AJ, Olsson SB, Malik M (2001) Diurnal variations of the dominant cycle length of chronic atrial fibrillation. Am J Physiol Heart Circ Physiol 280:H401–H406 es_ES
dc.description.references Nagahara Y (2004) A method of simulating multivariate nonnormal distributions by the Pearson distribution system and estimation. Comput Stat Data Anal 47:1–29 es_ES
dc.description.references Nie H, Chen SH (2007) Lognormal sum approximation with type IV Pearson distribution. IEEE Commun Lett 11:790–792 es_ES
dc.description.references Pearson K (1895) Contributions to the mathematical theory of evolution. II. Skew variation in homogeneous material. Philos Trans R Soc Lond A 186:343–414 es_ES
dc.description.references Richter U, Bollmann A, Husser D, Stridh M (2009) Right atrial organization and wavefront analysis in atrial fibrillation. Med Biol Eng Comput 47:1237–1246 es_ES
dc.description.references Sandberg F, Bollmann A, Husser D, Stridh M, Sornmo L (2010) Circadian variation in dominant atrial fibrillation frequency in persistent atrial fibrillation. Physiol Meas 31:531–542 es_ES
dc.description.references Schoenwald AT, Sahakian AV, Sih HJ, Swiryn S (1998) Further observations of “linking” of atrial excitation during clinical atrial fibrillation. Pacing Clin Electrophysiol 21:25–34 es_ES
dc.description.references Tadros R, Billette J (2009) Rate-dependent AV nodal refractoriness: a new functional framework based on concurrent effects of basic and pretest cycle length. Am J Physiol Heart Circ Physiol 297:H2136–H2143 es_ES
dc.description.references Tadros R, Lavallee M, Billette J (2006) Unified rate-dependent atrioventricular nodal function: consistent recovery and fatigue properties revealed with S1S2S3 protocols and different recovery indexes. Heart Rhythm 3:959–966 es_ES
dc.description.references Tadros R, Lavallee M, Billette J (2007) Dependence of AV nodal function curves on the selected recovery index: pivotal role of pretest conduction time. J Cardiovasc Electrophysiol 18:978–984 es_ES
dc.description.references Talajic M, Papadatos D, Villemaire C, Glass L, Nattel S (1991) A unified model of atrioventricular nodal conduction predicts dynamic changes in Wenckebach periodicity. Circ Res 68:1280–1293 es_ES
dc.description.references Vaya C, Rieta JJ (2009) Time and frequency series combination for non-invasive regularity analysis of atrial fibrillation. Med Biol Eng Comput 47:687–696 es_ES
dc.description.references Zeng W, Glass L (1996) Statistical properties of heartbeat intervals during atrial fibrillation. Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics 54:1779–1784 es_ES
dc.description.references Zhang YH, Mazgalev TN (2004) Ventricular rate control during atrial fibrillation and AV node modifications: past, present, and future. Pacing Clin Electrophysiol 27:382–393 es_ES
dc.description.references Zhang QT, Song SH (2008) A systematic procedure for accurately approximating lognormal-sum distributions. IEEE Trans Veh Technol 57:663–666 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem