dc.contributor.author |
Dobosz, Paulina Dorota
|
es_ES |
dc.contributor.author |
Morais, Sergi
|
es_ES |
dc.contributor.author |
Bonet, Emilio
|
es_ES |
dc.contributor.author |
Puchades, Rosa
|
es_ES |
dc.contributor.author |
Maquieira Catala, Ángel
|
es_ES |
dc.date.accessioned |
2016-07-07T07:19:48Z |
|
dc.date.issued |
2015-10-06 |
|
dc.identifier.issn |
0003-2700 |
|
dc.identifier.uri |
http://hdl.handle.net/10251/67275 |
|
dc.description.abstract |
[EN] An immuno multiresidue screening assay in microarray format for the determination of complex chemical mixtures at the microgram per liter level, using antibody-functionalized gold nanoparticles, is presented. The analytical method relies on the use of a cocktail of nanogold-labeled specific antibodies, acting as recognition and detection species. The concept of multireside screening is proved by developing a multiplex assay on a compact disk support for the determination of 2-(2,4,5-
trichlorophenoxy)propionic acid, 3-phenoxybenozic acid, 4-nitrophenol, alachlor, atrazine, azoxystrobin, chlorpyrifos, diazinon, diuron, endosulfan, fenthion, forchlorfenuron, imidacloprid, malathion, pentachlorophenol, pyraclostrobin, sulfasalazine, and triclosan, achieving detection limits of 0.07, 0.24, 10.9, 0.21, 0.14, 0.11, 0.11, 102, 0.36, 1.8, 1.7, 0.06, 0.08, 5.8, 1.0, 0.39, 0.003, and 12 ug/L, respectively. Due to the selectivity of the antibody-functionalized nanoparticles, the developed screening methodology allows the simultaneous determination of mixtures of water pollutants in a 10-plex configuration. The analytical performances were compared with those of reference chromatographic methods by the analysis of spiked water samples, the sensitivity and recovery results being in good agreement. The presented screening approach directly quantifies the concentration of complex chemical mixtures without sample treatment or preconcentration steps in a total time of 35 min. |
es_ES |
dc.description.sponsorship |
This work was supported by the Spanish Ministry of Economy and Competitiveness (Project CTQ2013-45875-R) and by the Generalitat Valenciana (Grants PROMETEO II 2014/040 and ACOMP 2012/158). P.D. acknowledges a fellowship (Grant Grisolia 2011/010) funded by the Generalitat Valenciana for her Ph.D. studies. Dr. A. Montoya, Dr. A. Abad-Fuentes, Dr. Shirley Gee, and Prof. Bruce D. Hammock kindly provided some of the coating conjugates and antibodies used in this work. |
en_EN |
dc.language |
Inglés |
es_ES |
dc.publisher |
American Chemical Society |
es_ES |
dc.relation.ispartof |
Analytical Chemistry |
es_ES |
dc.rights |
Reserva de todos los derechos |
es_ES |
dc.subject |
LINKED-IMMUNOSORBENT-ASSAY |
es_ES |
dc.subject |
MONOCLONAL-ANTIBODIES |
es_ES |
dc.subject |
DISK |
es_ES |
dc.subject |
TECHNOLOGY |
es_ES |
dc.subject |
EXTRACTION |
es_ES |
dc.subject |
PESTICIDE |
es_ES |
dc.subject |
RESIDUES |
es_ES |
dc.subject |
SAMPLES |
es_ES |
dc.subject |
ELISA |
es_ES |
dc.subject.classification |
QUIMICA ANALITICA |
es_ES |
dc.title |
Massive Immuno Multiresidue Screening of Water Pollutants |
es_ES |
dc.type |
Artículo |
es_ES |
dc.embargo.lift |
10000-01-01 |
|
dc.embargo.terms |
forever |
es_ES |
dc.identifier.doi |
10.1021/acs.analchem.5b02354 |
|
dc.relation.projectID |
info:eu-repo/grantAgreement/MINECO//CTQ2013-45875-R/ES/BIOSENSADO EN SOPORTES INTERACTIVOS CON PROPIEDADES INTERFEROMETRICAS PARA APLICACIONES CLINICAS. DEMOSTRACION EN FARMACOGENETICA Y ALERGIAS MEDICAMENTOSAS/ |
es_ES |
dc.relation.projectID |
info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2014%2F040/ES/Estudio de estrategias fisico-químicas para el desarrollo de biosensores interferométricos en soportes interactivos de aplicación en clínica/ |
es_ES |
dc.relation.projectID |
info:eu-repo/grantAgreement/GVA//ACOMP%2F2012%2F158/ |
es_ES |
dc.relation.projectID |
info:eu-repo/grantAgreement/GVA//GRISOLIA%2F2011%2F010/ |
es_ES |
dc.rights.accessRights |
Cerrado |
es_ES |
dc.contributor.affiliation |
Universitat Politècnica de València. Departamento de Química - Departament de Química |
es_ES |
dc.description.bibliographicCitation |
Dobosz, PD.; Morais, S.; Bonet, E.; Puchades, R.; Maquieira Catala, Á. (2015). Massive Immuno Multiresidue Screening of Water Pollutants. Analytical Chemistry. 87(19):9817-9824. https://doi.org/10.1021/acs.analchem.5b02354 |
es_ES |
dc.description.accrualMethod |
S |
es_ES |
dc.relation.publisherversion |
https://dx.doi.org/10.1021/acs.analchem.5b02354 |
es_ES |
dc.description.upvformatpinicio |
9817 |
es_ES |
dc.description.upvformatpfin |
9824 |
es_ES |
dc.type.version |
info:eu-repo/semantics/publishedVersion |
es_ES |
dc.description.volume |
87 |
es_ES |
dc.description.issue |
19 |
es_ES |
dc.relation.senia |
297336 |
es_ES |
dc.identifier.eissn |
1520-6882 |
|
dc.contributor.funder |
Ministerio de Economía y Competitividad |
|
dc.contributor.funder |
Generalitat Valenciana |
|