Mostrar el registro sencillo del ítem
dc.contributor.author | Rodríguez-Hernández, Miguel A. | es_ES |
dc.date.accessioned | 2017-06-15T12:07:29Z | |
dc.date.available | 2017-06-15T12:07:29Z | |
dc.date.issued | 2016-04 | |
dc.identifier.issn | 1746-8094 | |
dc.identifier.uri | http://hdl.handle.net/10251/82891 | |
dc.description.abstract | Denoising of biomedical signals using wavelet transform is a widely used technique. The use of undecimated wavelet transform (UWT) assures better denoising results but implies a higher complexity than discrete wavelet transform (DWT). Some implementation schemes have been proposed to perform UWT, one of them is Cycle Spinning (CS). CS is performed using the DWT of several circular shifted versions of the signal to analyse. The reduction of the number of shifted versions of the biomedical signal during denoising process used is addressed in the present work. This paper is about a variant of CS with a reduced number of shifts, called Partial Cycle Spinning (PCS), applied to ultrasonic trace denoising. The influence of the choice of PCS shifts in the denoised registers quality is studied. Several shifts selection rules are proposed, compared and evaluated. Denoising results over a set of ultrasonic registers are provided for PCS with different shift selection rules, CS and DWT. The work shows that PCS with the appropriate choice of shifts could be the best option to denoise biomedical ultrasonic traces. (C) 2015 Elsevier Ltd. All rights reserved. | es_ES |
dc.description.sponsorship | This work was partially supported by Spanish Government MEC Project TIN2013-47272-C2-1-R. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Biomedical Signal Processing and Control | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Denoising | es_ES |
dc.subject | Cycle spinning | es_ES |
dc.subject | Ultrasonics | es_ES |
dc.subject | Biomedical signals | es_ES |
dc.subject | Wavelets | es_ES |
dc.subject.classification | TEORIA DE LA SEÑAL Y COMUNICACIONES | es_ES |
dc.title | Shift Selection Influence in Partial Cycle Spinning Denoising of Biomedical Signals | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.bspc.2015.12.002 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//TIN2013-47272-C2-1-R/ES/PLATAFORMA DE SERVICIOS PARA CIUDADES INTELIGENTES CON REDES M2M DENSAS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros de Telecomunicación - Escola Tècnica Superior d'Enginyers de Telecomunicació | es_ES |
dc.description.bibliographicCitation | Rodríguez-Hernández, MA. (2016). Shift Selection Influence in Partial Cycle Spinning Denoising of Biomedical Signals. Biomedical Signal Processing and Control. 26:64-68. https://doi.org/10.1016/j.bspc.2015.12.002 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.bspc.2015.12.002 | es_ES |
dc.description.upvformatpinicio | 64 | es_ES |
dc.description.upvformatpfin | 68 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 26 | es_ES |
dc.relation.senia | 299341 | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |