Mostrar el registro sencillo del ítem
dc.contributor.author | Pérez-Sánchez, Modesto | es_ES |
dc.contributor.author | Sánchez-Romero, Francisco-Javier | es_ES |
dc.contributor.author | López-Jiménez, P. Amparo | es_ES |
dc.date.accessioned | 2017-10-25T06:43:06Z | |
dc.date.available | 2017-10-25T06:43:06Z | |
dc.date.issued | 2017-07-27 | |
dc.identifier.issn | 1134-2196 | |
dc.identifier.uri | http://hdl.handle.net/10251/89974 | |
dc.description.abstract | [EN] The energy audits are tools which allow to analyse the state of the water distribution network where the energy consumption depends on annual flow pattern (RQ). The present research develops a methodology to compare the energy footprint of water (EWF) through an energy balance with different RQs. The aim is to determine the energy behaviour of a network based on RQ value. The study analyses four networks (two drinking and two irrigation networks), showing a lower total energy consumption (5.22, 3.21, and 4.01%) and a lower friction energy (28.57, 21.42, and 25%) those networks with RQ less variable when these networks are compared with the network with more variability RQ. As novelty, the research defines a non-dimensional EWF parameter, which allows comparing EWF between different networks. This parameter can be introduced as sustainability index in the networks sizing jointed to technical and economic criteria. | es_ES |
dc.description.abstract | [ES] Las auditorías energéticas son herramientas que permiten analizar la situación de las redes de distribución, donde el consumo energético depende del patrón de caudal anual (RQ). En este trabajo se desarrolla una metodología para poder comparar la huella energética del agua (HEA) a través de un balance energético con diferente RQs. El objetivo es determinar el comportamiento energético de una red en base a RQ. El estudio analiza cuatro redes (dos de abastecimiento y dos de riego) mostrando que aquellas que presentan un RQ menos variable tienen un menor consumo de energía total (5.22, 3.21, y 4.01%) y de fricción (28.57, 21.42 y 25%) frente a la red con un RQ más variable. Como novedad, el trabajo define el parámetro HEA adimensional, el cual permite comparar la HEA entre diferentes redes, pudiendo ser introducido como índice de sostenibilidad en el dimensionado junto a los criterios técnicos y económicos. | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | |
dc.relation.ispartof | Ingeniería del Agua | |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Huella energética (HEA) | es_ES |
dc.subject | Patrón de consumo | es_ES |
dc.subject | Eficiencia energética | es_ES |
dc.subject | Redes de distribución presurizadas | es_ES |
dc.subject | Energy footprint of water (EWF) | es_ES |
dc.subject | Consumption pattern | es_ES |
dc.subject | Energy efficiency | es_ES |
dc.subject | Water pressurized distribution networks | es_ES |
dc.title | Huella energética del agua en función de los patrones de consumo en redes de distribución | es_ES |
dc.title.alternative | Energy footprint of water depending on consumption patterns in pressurized water networks | es_ES |
dc.type | Artículo | es_ES |
dc.date.updated | 2017-10-25T06:25:22Z | |
dc.identifier.doi | 10.4995/ia.2017.7096 | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Politécnica Superior de Alcoy - Escola Politècnica Superior d'Alcoi | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Rural y Agroalimentaria - Departament d'Enginyeria Rural i Agroalimentària | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural - Escola Tècnica Superior d'Enginyeria Agronòmica i del Medi Natural | es_ES |
dc.description.bibliographicCitation | Pérez-Sánchez, M.; Sánchez-Romero, F.; López-Jiménez, PA. (2017). Huella energética del agua en función de los patrones de consumo en redes de distribución. Ingeniería del Agua. 21(3):197-212. https://doi.org/10.4995/ia.2017.7096 | es_ES |
dc.description.accrualMethod | SWORD | es_ES |
dc.relation.publisherversion | https://doi.org/10.4995/ia.2017.7096 | es_ES |
dc.description.upvformatpinicio | 197 | es_ES |
dc.description.upvformatpfin | 212 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 21 | |
dc.description.issue | 3 | |
dc.identifier.eissn | 1886-4996 | |
dc.description.references | Abadia, R., Rocamora, C., Ruíz, C., 2008. Protocolo de Auditoría Energética en Comunidades de Regantes. IDAE, Madrid, Spain. | es_ES |
dc.description.references | Araujo, L.S., Ramos, H., Coelho, S.T., 2006. Pressure Control for Leakage Minimisation in Water Distribution Systems Management. Water Resources Management. 20, 133-149. doi:10.1007/s11269-006-4635-3 | es_ES |
dc.description.references | Berbel, J., Gutiérrez-Martín, C., Camacho, E., Montesinos, P., Rodriguez, 2014. "Efectos de la modernización de regadíos en el consumo de agua, energía y coste" in: Congreso de Regantes de Huelva. Universidad de Córdoba. | es_ES |
dc.description.references | Cabrera, E., Almandoz, J., Arregui, F., García-Serra, J., 1998. Auditoría de Redes de Distribución de Agua. Ingeniería del Agua 6(4) 387-399. doi:10.4995/ia.1999.2794 | es_ES |
dc.description.references | Cabrera, E., Cobacho, R., Soriano, J., 2014. Towards an Energy Labelling of Pressurized Water Networks. Procedia Engineering. 70, 209-217. doi:10.1016/j.proeng.2014.02.024 | es_ES |
dc.description.references | Cabrera, E., Pardo, M.; Cobacho, R., Cabrera Jr., E., 2010. Energy audit of water networks. Journal Water Resource Planning and Management. 136, 669-677. doi:10.1061/(ASCE)WR.1943-5452.0000077 | es_ES |
dc.description.references | Carravetta, A., Del Giudice, G., Fecarotta, O., Ramos, H., 2013a. Pump as Turbine (PAT) Design in Water Distribution Network by System Effectiveness. Water 5, 1211-1225. doi:10.3390/w5031211 | es_ES |
dc.description.references | Carravetta, A., Del Giudice, G., Fecarotta, O., Ramos, H., 2013b. PAT Design Strategy for Energy Recovery in Water Distribution Networks by Electrical Regulation. Energies 6, 411-424. doi:10.3390/en6010411 | es_ES |
dc.description.references | Carravetta, A., Fecarotta, O., Del Giudice, G., Ramos, H., 2014. Energy Recovery in Water Systems by PATs: A Comparisons among the Different Installation Schemes. Procedia Engineering 70, 275-284. doi:10.1016/j.proeng.2014.02.031 | es_ES |
dc.description.references | Corominas, J. 2010. Agua y Energía en el riego en la época de la sostenibilidad. Ingeniería del Agua, 17(3), 219-233. https://doi.org/10.4995/ia.2010.2977 | es_ES |
dc.description.references | Gómez, E. 2016. Caracterización y mejora de la eficiencia energética del transporte de agua a presión. PhD Thesis. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/72637 | es_ES |
dc.description.references | Granados García, A. 2013. Criterios para el dimensionamiento de redes de riego robustas frente a cambios en la alternativa de cultivos. PhD Thesis. E.T.S.I. Caminos, Canales y Puertos (UPM). | es_ES |
dc.description.references | Jiménez-Bello, M.A., Royuela, A., Manzano, J., Prats, A.G., Martínez-Alzamora, F., 2015. Methodology to improve water and energy use by proper irrigation scheduling in pressurised networks. Agricultural Water Management. 149, 91-101. doi:10.1016/j.agwat.2014.10.026 | es_ES |
dc.description.references | Klein, G., Krebs, M., Hall, V., O'Brien, T., Blevins, B.B. 2005. California's Water - Energy Relationship, California Energy Comission. | es_ES |
dc.description.references | López-Cortijo, I., Esquiroz, J.C., Aliod, R., García, S., 2007. Determinación de los costes energéticos en el cálculo de redes a presión con bombeo directo in: XXV Congreso Nacional de Riegos. Pamplona. | es_ES |
dc.description.references | McNabola, A., Coughlan, P., Corcoran, L., Power, C., Prysor Williams, A., Harris, I., Gallagher, J., Styles, D., 2014. Energy recovery in the water industry using micro-hydropower: an opportunity to improve sustainability. Water Policy 16, 168. doi:10.2166/wp.2013.164 | es_ES |
dc.description.references | Moreno, M., Córcoles, J., Tarjuelo, J., Ortega, J., 2010. Energy efficiency of pressurised irrigation networks managed on-demand and under a rotation schedule. Biosystems Engineering 107, 349-363. doi:10.1016/j.biosystemseng.2010.09.009 | es_ES |
dc.description.references | Munizaga, E., 1976. Redes de agua potable: diseño y dimensionamiento. Instituto Eduardo Torroja. Monografía num. 335. | es_ES |
dc.description.references | Pardo, M.A., Manzano, J., Cabrera, E., García-Serra, J., 2013. Energy audit of irrigation networks. Biosystems Engineering. 115, 89-101. doi:10.1016/j.biosystemseng.2013.02.005 | es_ES |
dc.description.references | Pérez-García, R., 1993. Dimensionado óptimo de redes de distribución de agua ramificadas considerando los elementos de regulación. Universitat Politècnica de Valencìa. | es_ES |
dc.description.references | Pérez-Sánchez, M., Sánchez-Romero, F., Ramos, H., López-Jiménez, P., 2016. Modeling Irrigation Networks for the Quantification of Potential Energy Recovering: A Case Study. Water 8, 1-26. doi:10.3390/w8060234 | es_ES |
dc.description.references | Planells, P., Ortega, J.F., 2006. Selección de bombas en redes de riego a presión. Ingeniería del Agua 6, 47-57. https://doi.org/10.4995/ia.2006.2881 | es_ES |
dc.description.references | Pulido-Calvo, I., Roldán, J., López-Luque, R., Gutiérrez-Estrada, J.C. 2003. Water Delivery System Planning Considering Irrigation Simultaneity. Journal Irrigation and Drainage Engineering, 129, 247-255. https://doi.org/10.1061/(ASCE)0733-9437(2003)129:4(247) | es_ES |
dc.description.references | Ramos, H., Borga, A. 1999. Pumps as turbines: an unconventional solution to energy production. Urban Water, 1, 261-263. https://doi.org/10.1016/S1462-0758(00)00016-9 | es_ES |
dc.description.references | Ramos, H., Mello, M., De, P.K. 2010. Clean power in water supply systems as a sustainable solution: from planning to practical implementation. Water Science and Technology Water Supply, 10, 39-49. https://doi.org/10.2166/ws.2010.720 | es_ES |
dc.description.references | Vanham, D., Bidoglio, G. 2013. A review on the indicator water footprint for the EU28. Ecological Indicators, 26, 61-75. https://doi.org/10.1016/j.ecolind.2012.10.021 | es_ES |
dc.description.references | Walkenbach, J. 2010. Excel 2010. Programación con VBA. Editorial Anaya. Madrid. https://doi.org/10.1002/9781118257616 | es_ES |
dc.description.references | White, F.M., 2008. Fluid Mechanics, 6th. ed. McGrau-Hill. | es_ES |