<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T16:48:59Z</responseDate><request verb="GetRecord" identifier="oai:riunet.upv.es:10251/1981" metadataPrefix="dim">https://riunet.upv.es/server/oai/request</request><GetRecord><record><header><identifier>oai:riunet.upv.es:10251/1981</identifier><datestamp>2026-04-02T14:29:19Z</datestamp><setSpec>com_10251_11198</setSpec><setSpec>col_10251_321</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" authority="virtual::114481" confidence="-1">Garcerá Sanfeliú, Gabriel</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="virtual::25275" confidence="-1">Pascual Molto, Marcos</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="affiliation" authority="virtual::886130" confidence="-1">Departamento de Física Aplicada</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="affiliation" authority="virtual::906680" confidence="-1">Departamento de Ingeniería Electrónica</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="affiliation" authority="virtual::1114226" confidence="-1">Escuela Técnica Superior de Ingeniería Industrial</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="affiliation" authority="virtual::1146731" confidence="-1">Escuela Politécnica Superior de Alcoy</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="affiliation" authority="virtual::1200801" confidence="-1">Grupo de Sistemas Electrónicos Industriales</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-05-07</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-05-07</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="created" lang="es_ES">2008-01-25</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="es_ES">2008-05-07</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://riunet.upv.es/handle/10251/1981</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi" lang="es_ES">info:doi:10.4995/Thesis/10251/1981</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="es_ES">Los sistemas de conversión conectados en paralelo constituyen una solución interesante al problema de proporcionar una tensión regulada a una carga que demanda corrientes elevadas, pues la paralelización de convertidores permite distribuir la corriente entre los diversos módulos, reduciendo el estrés sobre los interruptores y mejorando la fiabilidad del
sistema.

En sistemas multimodulares de convertidores se necesita normalmente un esquema de control modo corriente, como el control modo corriente media (ACC en inglés), que asegure una correcta compartición de corriente entre los distintos módulos. 
Con este tipo de control, las características dinámicas del lazo de control dependen considerablemente de las
condiciones de línea y carga, así como del número de módulos conectados en paralelo.

En esta tesis se han aplicado dos técnicas diferentes de control robusto basado en modelo de referencia (RMF en inglés) a sistemas de conversión en paralelo con el fin de mejorar la robustez del control ACC convencional. El trabajo realizado puede dividirse en tres grandes bloques:

En primer lugar, se ha presentado un esquema de control RMF paso-alto que ha sido aplicado al lazo de tensión de un 
convertidor DC-DC multimodular tipo Buck. El esquema de control propuesto añade un lazo interno adicional a los lazos de corriente y de tensión del control ACC convencional, reduciendo la sensibilidad del lazo externo de tensión frente a los 
parámetros variables de la etapa de potencia: número de módulos, tensión de entrada, carga y tolerancias de los componentes.
Además, el lazo mejora considerablemente el rechazo de perturbaciones del convertidor, esto es, impedancia de salida y 
audiosusceptibilidad en lazo cerrado, en baja frecuencia si se compara con el control ACC convencional.
  
La principal limitación de este esquema de control es que su funcionamiento está limitado por el rizado de conmutación 
presente en la tensión de salida, dado que se utiliza un regulador auxiliar......</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="bibliographicCitation" lang="es_ES">Pascual Molto, M. (2008). Técnicas de control robusto basado en modelo de referencia aplicadas a sistemas modulares de alimentación [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/1981</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="accrualMethod" lang="es_ES">Palancia</dim:field>
   <dim:field mdschema="dc" element="language" lang="es_ES">spa</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="es_ES">Universitat Politècnica de València</dim:field>
   <dim:field mdschema="dc" element="rights" lang="es_ES">http://rightsstatements.org/vocab/InC/1.0/</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="accessRights" lang="es_ES">info:eu-repo/semantics/openAccess</dim:field>
   <dim:field mdschema="dc" element="source">Riunet</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Sai</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Ups</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Inversor monofásico</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Control robusto</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Sistema multimodular</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Buck</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Acc</dim:field>
   <dim:field mdschema="dc" element="subject" lang="es_ES">Control modo corriente media</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="classification" lang="es_ES">TECNOLOGIA ELECTRONICA</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="unesco" lang="es_ES">3307 - Tecnología electrónica</dim:field>
   <dim:field mdschema="dc" element="title">Técnicas de control robusto basado en modelo de referencia aplicadas a sistemas modulares de alimentación</dim:field>
   <dim:field mdschema="dc" element="type" lang="es_ES">info:eu-repo/semantics/doctoralThesis</dim:field>
   <dim:field mdschema="dc" element="type" qualifier="version" lang="es_ES">info:eu-repo/semantics/acceptedVersion</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="relation" element="isAuthorOfPublication" authority="virtual::25275" confidence="-1">0ea89bd8-3dd1-4c39-a910-2db0ae984145</dim:field>
   <dim:field mdschema="relation" element="isAuthorOfPublication" qualifier="latestForDiscovery" authority="virtual::25275" confidence="-1">0ea89bd8-3dd1-4c39-a910-2db0ae984145</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" authority="virtual::886130" confidence="-1">647b4468-9f57-4ef5-bf54-fab9f510ac60</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" authority="virtual::906680" confidence="-1">a3ca7df3-e467-4f69-b673-79a5d6241220</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" authority="virtual::1114226" confidence="-1">8ae78ce8-addb-4436-ab5a-a92b5c530aff</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" authority="virtual::1146731" confidence="-1">96a57980-3fe4-46f5-8a98-7c3aac322fc5</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" authority="virtual::1200801" confidence="-1">f00fcd68-a3d5-49a4-a164-ba835ffa528e</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" qualifier="latestForDiscovery" authority="virtual::886130" confidence="-1">647b4468-9f57-4ef5-bf54-fab9f510ac60</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" qualifier="latestForDiscovery" authority="virtual::906680" confidence="-1">a3ca7df3-e467-4f69-b673-79a5d6241220</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" qualifier="latestForDiscovery" authority="virtual::1114226" confidence="-1">8ae78ce8-addb-4436-ab5a-a92b5c530aff</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" qualifier="latestForDiscovery" authority="virtual::1146731" confidence="-1">96a57980-3fe4-46f5-8a98-7c3aac322fc5</dim:field>
   <dim:field mdschema="relation" element="isOrgUnitOfPublication" qualifier="latestForDiscovery" authority="virtual::1200801" confidence="-1">f00fcd68-a3d5-49a4-a164-ba835ffa528e</dim:field>
   <dim:field mdschema="relation" element="isAdvisorOfPublication" authority="virtual::114481" confidence="-1">589abc2b-ac7f-44d8-86cd-ef781013e7fc</dim:field>
   <dim:field mdschema="relation" element="isAdvisorOfPublication" qualifier="latestForDiscovery" authority="virtual::114481" confidence="-1">589abc2b-ac7f-44d8-86cd-ef781013e7fc</dim:field>
   <dim:field mdschema="person" element="identifier" authority="virtual::114481" confidence="-1">2748</dim:field>
   <dim:field mdschema="person" element="identifier" authority="virtual::25275" confidence="-1">17663</dim:field>
   <dim:field mdschema="person" element="identifier" qualifier="orcid" authority="virtual::114481" confidence="-1">0000-0002-5507-4379</dim:field>
   <dim:field mdschema="person" element="identifier" qualifier="orcid" authority="virtual::25275" confidence="-1">0000-0002-9337-9755</dim:field>
   <dim:field mdschema="upv" element="uuid" lang="es_ES">45bb04c1-ba00-4dfc-bd54-79904f362624</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>