Gahete Arias, CarlosBaquero Escudero, MarianoValero-Nogueira, AlejandroVila Jiménez, Antonio2014-11-192014-11-192013-061531-1309https://riunet.upv.es/handle/10251/44429This letter presents a Test-Fixture for a Suspended-Strip Gap-Waveguide technology that provides a fast measurement system for the prototyping stage. For this purpose, a transition from standard rectangular waveguide to this new technology has been developed. A TRL kit and a repeatability study have been made to ensure the reliability of the process, and several straightforward circuits have been manufactured and measuredReserva de todos los derechosMillimeter-waveridge gap-waveguide (RGW)test-fixtureMillimetre wave devicesTestingWaveguidesTEORIA DE LA SEÑAL Y COMUNICACIONESTest-Fixture for Suspended-Strip Gap-Waveguide Technology on Ka-BandArtículo10.1109/LMWC.2013.2258000Abierto