FERNÁNDEZ DÍAZ, ROMÁN; Calero-Alcarria, María Del Señor; García Narbón, José Vicente; Reiviakine, Ilya; Arnau Vives, Antonio; Jiménez Jiménez, Yolanda(Institute of Electrical and Electronics Engineers, 2021-03-01)
[EN] Improvement of data acquisition rate remains as an important challenge in applications with Quartz Crystal Microbalance (QCM) technology where high throughput is required. To address this challenge, we developed a ...
Calero-Alcarria, María Del Señor; FERNÁNDEZ DÍAZ, ROMÁN; GARCIA MOLLA, PABLO; García Narbón, José Vicente; García, María; Gamero-Sandemetrio, Esther; Reviakine, Ilya; Arnau Vives, Antonio; Jiménez Jiménez, Yolanda(MDPI AG, 2020-11-24)
[EN] Integrating acoustic wave sensors into lab-on-a-chip (LoC) devices is a well-known challenge. We address this challenge by designing a microfluidic device housing a monolithic array of 24 high-fundamental frequency ...
Forcada García, Manel(Universitat Politècnica de València, 2023-10-05)
[ES] AWSensors es una empresa que diseña sistemas basados en QCMD, incluyendo arrays de sensores, equipos electrónicos, sistemas de fluídica, sistemas de control de temperatura, sistemas de entrega de muestras, etc.
También ...
FERNÁNDEZ DÍAZ, ROMÁN; García Molla, Pablo; García, María; García Narbón, José Vicente; Jiménez Jiménez, Yolanda; Arnau Vives, Antonio(MDPI AG, 2017-09-08)
[EN] Acoustic wave resonators have become suitable devices for a broad range of sensing applications due to their sensitivity, low cost, and integration capability, which are all factors that meet the requirements for the ...
Calero Alcarria, María del Señor(Universitat Politècnica de València, 2017-12-02)
One of the outstanding challenges in the areas of health and food safety and quality is the development of new High-Throughput Screenig (HTS) techniques that allow the simultaneous monitoring of multiple samples. A key ...
Molina Rosa, Carlos(Universitat Politècnica de València, 2015-02-04)
Este trabajo fin de grado está enmarcado dentro del proyecto que actualmente se está desarrollando en la empresa AWSensors SL, y que consiste en el desarrollo de una nueva versión de las plataformas AWS A20 RP y AWS F20 ...
Montagut Ferizzola, Yeison Javier; García Narbón, José Vicente; Jiménez Jiménez, Yolanda; March Iborra, Mª Del Carmen; Montoya Baides, Ángel; Arnau Vives, Antonio(American Institute of Physics (AIP), 2011)
The improvement of sensitivity in quartz crystal microbalance (QCM) applications has been addressed in the last decades by increasing the sensor fundamental frequency, following the increment of the frequencymass sensitivity ...
FERNÁNDEZ DÍAZ, ROMÁN; Calero-Alcarria, María Del Señor; Reviakine, Ilya; García, José Vicente; Rocha-Gaso, María Isabel; Arnau Vives, Antonio; Jiménez Jiménez, Yolanda(Institute of Electrical and Electronics Engineers, 2021-01-01)
[EN] Miniaturized, high-throughput, cost-effective sensing devices are needed to advance lab-on-a-chip technologies for healthcare, security, environmental monitoring, food safety, and research applications. Quartz crystal ...
March Iborra, Mª Del Carmen; García Narbón, José Vicente; Sánchez, Ángel; Arnau Vives, Antonio; Jiménez Jiménez, Yolanda; García, Pablo; Manclus Ciscar, Juan José; Montoya Baides, Ángel(Elsevier, 2015-03-15)
[EN] In spite of being widely used for in liquid biosensing applications, sensitivity improvement of conventional (5-20 MHz) quartz crystal microbalance (QCM) sensors remains an unsolved challenging task. With the help of ...
García Narbón, José Vicente(Universitat Politècnica de València, 2016-05-02)
[EN] Different electronic interfaces have been proposed to measure major parameters for the characterization of quartz crystal microbalance (QCM) during the last two decades. The measurement of the adequate parameters of ...
García Narbón, José Vicente; Rocha, M.I.; March Iborra, Mª Del Carmen; García, P.; Francis, Laurent A; Montoya Baides, Ángel; Arnau Vives, Antonio; Jiménez Jiménez, Yolanda(Elsevier, 2014)
[EN] In this work we determined the Sensitivity (estimated as the I50 value) and Limit of Detection (LOD) for the immunodetection of carbaryl pesticide with two different types of acoustic wave sensors: High Fundamental ...
Rocha-Gaso, María-Isabel; García Narbón, José Vicente; García, Pablo; March Iborra, Mª Del Carmen; Jiménez Jiménez, Yolanda; Francis, Laurent-Alain; Montoya Baides, Ángel; Arnau Vives, Antonio(MDPI, 2014-09-03)
A Love Wave (LW) immunosensor was developed for the detection of carbaryl
pesticide. The experimental setup consisted on: a compact electronic characterization
circuit based on phase and amplitude detection at constant ...
Molina Rosa, Carlos(Universitat Politècnica de València, 2017-05-03)
La plataforma AWS A20 es una plataforma universal para la caracterización de biosensores basados en tecnologías acústicas (www.awsensors.com). Dispone de 4 canales, lo que le permite realizar 4 medidas simultáneamente, ...
Montagut Ferizzola, Yeison Javier; García Narbón, José Vicente; Jiménez Jiménez, Yolanda; March Iborra, Mª Del Carmen; Montoya Baides, Ángel; Torres Villa, Robinsón Alberto; Arnau Vives, Antonio(Universidad de Antioquia. Facultad de Ingenieria, 2011-12)
[EN] Quartz crystal is generally used in some applications as a microbalance
taking advantage of its capacity to change the resonance frequency according
to any surface mass change on the resonator.In this way a quartz ...
El Fissi, L.; Fernández Díaz, Román; García Molla, Pablo; Calero-Alcarria, María Del Señor; García Narbón, José Vicente; Jiménez Jiménez, Yolanda; Arnau Vives, Antonio; Francis, Laurent Alain(Elsevier, 2019)
[EN] A new heterogeneous integration method is presented that allows the integration of a microfluidic platform and a multi-channel quartz crystal microbalance array on a printed circuit board (PCB) using a dry adhesive ...
Montagut, Yeison; García Narbón, José Vicente; Jiménez Jiménez, Yolanda; March Iborra, Mª Del Carmen; Montoya Baides, Ángel; Arnau Vives, Antonio(MDPI, 2011)
Acoustic wave resonator techniques are widely used in in-liquid biochemical applications. The main challenges remaining are the improvement of sensitivity and limit of detection, as well as multianalysis capabilities and ...