Juste Vidal, Belen Jeanine; Miró Herrero, Rafael; Verdú Martín, Gumersindo Jesús; Diez Domingo, Sergio; Campayo Esteban, Juan Manuel(Institute of Electrical and Electronics Engineers, 2011)
[EN] An accurate knowledge of the spectral distribution emission is essential for precise dose calculations in radiotherapy treatment planning. Reconstruction of photon spectra emitted by medical accelerators from measured ...
Mayo Nogueira, Patricia; Ródenas Escribá, Francisco De Asís; Verdú Martín, Gumersindo Jesús; Villaescusa, J.I; Campayo, Juan Manuel(Oxford University Press, 2005-12-20)
[EN] Mammographic phantom images are usually used to study the quality of images obtained by dedicated mammographic equipment. The digital image treatment techniques allow us to carry out an automatic analysis of the phantom ...
A precise estimation of the photon spectra emitted by radiation therapy Linacs is especially important to accurately estimate the dose received by patients in order to improve treatment plannings. Moreover the knowledge ...
Mayo Nogueira, Patricia; Ródenas Escribá, Francisco De Asís; Verdú Martín, Gumersindo Jesús; Villaescusa, J.I; Campayo, Juan Manuel(Elsevier, 2004-02)
[EN] In this work a method has been developed to analyse the digital image quality of a mammographic phantom by means of automatic process techniques. The techniques used for the digital image treatment are standard ...
Normalmente, los sistemas de planificación de tratamientos en radioterapia no
tienen en cuenta las posibles dosis recibidas por los pacientes debido a la contribución de
neutrones inducida por los haces de fotones de ...
Juste Vidal, Belen Jeanine; Miró Herrero, Rafael; Morera Cano, Daniel; Verdú Martín, Gumersindo Jesús; Campayo Esteban, Juan Manuel; Diez Domingo, Sergio(The Atomic Energy Society of Japan, 2014)
[EN] This work presents a technique to perform an electronic portal imaging device (EPID) signal planar
calibration into dose terms using Monte Carlo simulations. To that, a complete Monte Carlo (MC) simulation
of a ...
Campayo Esteban, Juan Manuel(Universitat Politècnica de València, 2008-05-07)
La valoración de la calidad de la imagen de un fantoma radiográfico es uno de los ejes fundamentales en un completo programa de control de calidad de equipamiento radiográfico. Para poder realizar un diagnostico adecuado ...
En radioterapia, los haces de fotones de alta energía producen dosis más bajas en la piel y una menor dosis dispersada en los tejidos sanos circundantes. Sin embargo, cuando se opera por encima de 10 MV los Linacs presentan ...
El presente trabajo se centra en una simulación con el código Monte Carlo MCNP5 de una unidad
de tratamiento de radioterapia con colimador multi-láminas (MLC, Multi-Leaf Collimator),
incluyendo su correspondiente dispositivo ...
Mayo Nogueira, Patricia; Verdú Martín, Gumersindo Jesús; Campayo Esteban, Juan Manuel(Grupo Senda, 2013-09)
En el presente trabajo se presentan diversos títulos de postgrado semipresenciales en materia de protección radiológica aplicados a instalaciones radiactivas y nucleares y al ámbito de la física hospitalaria, dirigidos a ...