[EN] This paper compares various proposals for codifying categorical attributes in a heart disease database
so that numerical clustering algorithms can be applied to them. An approach for the codification of
categorical ...
[EN] Continuous Glucose Monitoring (CGM) has been a springboard of new diabetes management technologies such as integrated sensor-pump systems, the artificial pancreas, and more recently, smart pens. It also allows patients ...
[EN] Type 1 diabetes is an autoimmune condition characterised by a pancreatic insulin secretion deficit, resulting in high blood glucose concentrations, which can lead to micro- and macrovascular complications. Type 1 ...
Barceló Rico, Fátima; Bondía Company, Jorge; Diez Ruano, José Luís; Rossetti ., Paolo(Mary Ann Liebert, 2012)
[EN] Background: Continuous glucose monitoring (CGM) devices estimate plasma glucose (PG) from measurements in compartments alternative to blood. The accuracy of currently available CGM is yet unsatisfactory and may depend ...
Beneyto, Aleix; Bertachi, Arthur; Bondía Company, Jorge; Vehí, Josep(Institute of Electrical and Electronics Engineers, 2020-03)
[EN] The artificial pancreas (AP) system or closed-loop blood glucose (BG) regulation is a technological advancement that aims to relieve diabetic subjects from their current decision-making burden while tightening their ...
[EN] Background:
Estimating the rate of glucose appearance (Ra) after ingestion of a mixed meal may be highly valuable in diabetes management. The gold standard technique for estimating Ra is the use of a multitracer oral ...
[EN] Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes ...
Cuerda del Pino, Alba; Rodrigo Martín-San Agustín; Diez, José-Luís; Laguna Sanz, Alejandro José; Palanca, Ana; Rossetti, Paolo; Gumbau-Gimenez, Maria; Ampudia-Blasco, Francisco Javier; Bondía Company, Jorge(Mary Ann Liebert, 2024-06-01)
[EN] Background: This study aimed to evaluate the accuracy of Dexcom G6 (DG6) and FreeStyle Libre-2 (FSL2) during aerobic training and high-intensity interval training (HIIT) in individuals with type 1 diabetes. Methods: ...
Barceló-Rico, Fátima; Diez, José-Luís; Rossetti, Paolo; Vehi, Josep; Bondía Company, Jorge(Institute of Electrical and Electronics Engineers, 2013)
[EN] Minimally or noninvasive continuous glucose monitors estimate plasma glucose from compartments alternative to blood, and may revolutionize the management of diabetes. However, the accuracy of current devices is still ...
Sanz Diaz, Ricardo; García Gil, Pedro José; Diez, José-Luís; Bondía Company, Jorge(Institute of Electrical and Electronics Engineers, 2021-01)
[EN] This brief is focused on the closed-loop control of postprandial glucose levels of patients with type 1 diabetes mellitus after unannounced meals, which is still a major challenge toward a fully autonomous artificial ...
[EN] Objective: To evaluate the safety and performance of a new multivariable closed-loop (MCL) glucose controller with automatic carbohydrate recommendation during and after unannounced and announced exercise in adults ...
[EN] Accurate blood glucose (BG) forecasting is key in diabetes management, as it allows preventive actions to mitigate harmful hypoglycemic/hyperglycemic episodes. Considering the encouraging results obtained by seasonal ...
[EN] Background: People with insulin-dependent diabetes rely on an intensified insulin regimen. Despite several guidelines, they
are usually impractical and fall short in achieving optimal glycemic outcomes. In this work, ...
Revert, Ana; Calm, Remei; Vehí, Josep; Bondía Company, Jorge(Institute of Electrical and Electronics Engineers, 2011-02)
[EN] Intensive insulin therapy in type 1 diabetes is based on the well-established practice of adjusting basal and bolus insulin independently. Basal insulin delivery is designed to optimize glucose concentrations between ...
[EN] Background: Postprandial (PP) control remains a challenge for closed-loop (CL) systems. Few studies with inconsistent results have systematically investigated the PP period.
Objective: To compare a new CL algorithm ...
[EN] Since the early 2000s, there has been an exponentially increasing development of new diabetes-applied technology such as continuous glucose monitoring, bolus calculators, and "smart" pumps, with the expectation of ...
[EN] In this paper, the problem of tackling uncertainty in the prediction of postprandial blood glucose is analyzed. Two simulation approaches, Monte Carlo and interval models, are studied and compared. Interval simulation ...
Furió Novejarque, Clara(Universitat Politècnica de València, 2024-02-26)
[ES] La regulación de los niveles de glucosa en el cuerpo humano es el resultado de la secreción coordinada de hormonas. La Diabetes Tipo 1 (DT1) es una enfermedad crónica que provoca la destrucción de las células responsables ...
Moscardó García, Vanessa(Universitat Politècnica de València, 2019-05-13)
[ES] Las personas con diabetes tipo 1 carecen de la capacidad de secretar insulina y, por lo tanto, necesitan regular su glucosa en sangre con la administración de insulina exógena. El páncreas artificial se presenta como ...
Revert Tomás, Ana(Universitat Politècnica de València, 2011-11-11)
Biological systems (biosystems), due to their complexity and multidisplinary character, are becoming one of the challenging research topics in the field of systems and control. In this work, several tools for dealing with ...