González Martínez, Antonio Javier; Conde, P.; Hernández Hernández, Liczandro; Herrero Bosch, Vicente; Moliner Martínez, Laura; Monzó Ferrer, José María; Orero Palomares, Abel; Peiró Cloquell, Antonio; Rodríguez-Alvarez, M.J.; Ros García, Ana; Sánchez Martínez, Filomeno; Soriano Asensi, Antonio; Vidal San Sebastián, Luis Fernando; Benlloch Baviera, Jose María(Elsevier, 2013-02-21)
In this paper we describe the overall design of a PET–MR system for head imaging within the
framework of the DREAM Project as well as the first detector module tests. The PET system design
consists of 4 rings of 16 ...
Benlloch Baviera, Jose María; González Martínez, Antonio Javier; Carrilero, V.; Catret, J. V.; Correcher, C.; Lerche, Christoph Werner; Morera, C.; Orero, A.; Pavón, N.; Ros García, Ana; Sánchez, F.; Soriano Asensi, Antonio; Vidal San Sebastián, Luis Fernando; Colom Palero, Ricardo José; Gadea Gironés, Rafael; Herrero Bosch, Vicente; Mora, C.; Mora Mas, Francisco José; Sebastia Cortes, Angel; Munar, A.(Sociedad Española de Física Médica, 2007)
[ES] En este artículo presentamos el diseño de un nuevo escáner
PET para animales pequeños basado en una tecnología completamente
innovadora. Los resultados preliminares son muy prometedores,
permitiendo obtener imágenes ...
Aliaga Varea, Ramón José; Herrero Bosch, Vicente; Monzó Ferrer, José María; Ros García, Ana; Gadea Gironés, Rafael; Colom Palero, Ricardo José(Institute of Electrical and Electronics Engineers (IEEE), 2014-02)
A DAQ architecture for a PET system is presented that focuses on modularity, scalability and reusability. The system defines two basic building blocks: data acquisitors and concentra- tors, which can be replicated in order ...
Monzó Ferrer, José María; Ros García, Ana; Herrero Bosch, Vicente; Perino Vicentini, Ivan Virgilio; Aliaga Varea, Ramón José; Gadea Gironés, Rafael; Colom Palero, Ricardo José(IOP Publishing: Hybrid Open Access, 2013-03)
[EN] Improving timing resolution in positron emission tomography (PET), thus having fine time information of the detected pulses, is important to increase the reconstructed images signal to noise ratio (SNR) [1]. In the ...
Herrero Bosch, Vicente; Monzó Ferrer, José María; Ros García, Ana; Aliaga Varea, Ramón José; González Martínez, Antonio Javier; Montoliu, C.; Colom Palero, Ricardo José; Benlloch Baviera, Jose María(IOP Publishing: Hybrid Open Access, 2012-12)
[EN] AMIC architecture has been introduced in previous works in order to provide a generic and expandable solution for implementing large number of outputs SiPM array/PMT detectors. The underlying idea in AMIC architecture ...
Benlloch Baviera, Jose María; Carrilero, V.; González Martínez, Antonio Javier; Catret, J.; Lerche, Christoph Werner; Abellan, D.; García de Quiros, F.; Gimenez, M.; Modia, J.; Sánchez, Filomeno; Ros García, Ana; Martínez, J.; Sebastia Cortes, Angel(Elsevier, 2007-02-01)
[EN] We have constructed a small animal PET with four identical detector modules, each consisting of a continuous LYSO crystal attached to a Position Sensitive Photomultiplier Tube (PSPMT). The dimensions of the continuous ...
González Martínez, Antonio Javier; Moreno, Manuel; Barberá, Julio; Conde Castellanos, Pablo Eloy; Hernández Hernández, Liczandro; Moliner Martínez, Laura; Monzó Ferrer, José María; Orero Palomares, Abel; Peiró Cloquell, Antonio; Polo Collado, Ramiro; Rodríguez Álvarez, María José; Ros García, Ana; Sánchez Martínez, Filomeno; Soriano Asensi, Antonio; Vidal San Sebastián, Luis Fernando; Benlloch Baviera, Jose María(Institute of Electrical and Electronics Engineers (IEEE), 2013-04)
[EN] In this work we describe a procedure to reduce the number of signals detected by an array of 256 Silicon Photo-multipliers (SiPMs) using a resistor network to divide the signal charge into few readout channels. Several ...