Igual Muñoz, Anna Neus; Mischler, Stefano(SPRINGER, 2011)
[EN] The corrosion behaviour and the wear ranking of biomedical high carbon (HC) and low carbon (LC) CoCrMo alloys sliding against an alumina ball in four different simulated body fluids [NaCl and phosphate buffered solutions ...
Igual Muñoz, Anna Neus; Mischler, Stefano(Elsevier, 2015-10-20)
Protein adsorption on biomedical CoCrMo alloys plays a crucial role in biocompatibility, corrosion and wear properties of implants. So far, protein adsorption was studied only on passive CoCrMo alloys above the open circuit ...
Cao, S.; Igual Muñoz, Anna Neus; Mischler, Stefano(NACE International, 2017)
[EN] In this study, the in vivo degradation of metal-on-metal (MoM) artificial hip joints was assessed based on the present state of the art concepts of tribocorrosion. A recently developed tribocorrosion model, based on ...
Park, Seong-Hyeon; Navarro-Laboulais, J.; Leyland, Pénélope; Mischler, Stefano(Elsevier, 2021-02)
[EN] Space debris that re-enter the Earth's atmosphere can be partially or fully ablated along the trajectory path after hitting the atmosphere layers, once these become denser (approximately below 82 km). This paper ...
Mischler, Stefano; Igual Muñoz, Anna Neus(Elsevier, 2013-01-15)
A good biocompatibility, excellent mechanical properties and high corrosion resistance characterize CoCrMo alloys. Therefore they are widely used for artificial joints in biomedical implants. However, the degradation of ...