[EN] Piezoelectric polymer cellular films have been studied since 1986. In recent years, they have improved the potential applications due to materials progress. Cellular polypropylene (PP) polymers are characterised by ...
Mier Escurra, Christian; Rodrigo Mor, Armando; Vaessen, Peter(Institute of Electrical and Electronics Engineers, 2021-09-01)
[EN] A recent investigation explored a new measuring concept used in partial discharges (PD) measurements in gas insulated substations (GIS), consisting of a magnetic loop antenna. The sensor¿s frequency response was ...
Yeo, Joel; Jin, Huifei; Rodrigo Mor, Armando; Yuen, Chau; Tushar, Wayes; Saha, Tapan K.; Seng Ng, Chee(Institute of Electrical and Electronics Engineers, 2021-06-30)
[EN] This paper proposes to administer a multi-step artificial intelligence approach with an ensemble of adaptive neural networks (NNs) trained on 50000 samples to identify partial discharge (PD) diagnostic measurements ...
[EN] This paper proposes an algorithmic approach constructed from a convolutional recurrent neural network (CRNN) iterated with examination of extracted features for partial discharge (PD) localisation; tests were conducted ...
Vu, Cong-Thanh; Toigo, Caterina; Jacquier, Frank; Girodet, Alain; Riechert, Uwe; Tuczek, Maximilian Nikolaus; Rodrigo Mor, Armando(Institute of Electrical and Electronics Engineers, 2022-12)
[EN] This article investigates the partial discharge (PD) behavior of protrusion defects in real-size high-voltage direct current gas insulated switchgear (HVDC GIS) for SF6 and SF6 alternative gases including fluoronitrile-CO2 ...
[EN] There are no accepted procedures that quantify the apparent charge of partial discharge (PD) in gas-insulated substations (GIS). This paper proposes a calibration method for PD charge estimation using unconventional ...
[EN]
One of the main difficulties in measuring partial discharges (PD) in gas-insulated substations (GIS) is the overlapping of pulses at the sensor's location, which distorts the pulse resolution and the charge estimation. ...
[EN]
On-site partial discharge (PD) measurements have turned out to be a very efficient technique for determining the insulation condition in high-voltage electrical grids (AIS, cable systems, GIS, HVDC converters, etc.); ...
Mier Escurra, Guillermo; Rodrigo Mor, Armando; Castro, Luis Carlos; Vaessen, Peter(MDPI AG, 2021-09)
[EN] Space charges are one of the main challenges facing the constantly increasing use of extruded high voltage direct current (HVDC) cables. The Pulsed Electro-Acoustic (PEA) method is one of the most common procedures ...
[EN] The insulation condition of HVDC grids consisting of cable systems, GIS, and converters should be monitored by partial discharge (PD) analysers using artificial intelligence (AI) tools for efficient insulation diagnosis. ...