Beneyto, Aleix; Bertachi, Arthur; Bondía Company, Jorge; Vehí, Josep(Institute of Electrical and Electronics Engineers, 2020-03)
[EN] The artificial pancreas (AP) system or closed-loop blood glucose (BG) regulation is a technological advancement that aims to relieve diabetic subjects from their current decision-making burden while tightening their ...
[EN] Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes ...
[EN] Objective: To evaluate the safety and performance of a new multivariable closed-loop (MCL) glucose controller with automatic carbohydrate recommendation during and after unannounced and announced exercise in adults ...
Revert, Ana; Calm, Remei; Vehí, Josep; Bondía Company, Jorge(Institute of Electrical and Electronics Engineers, 2011-02)
[EN] Intensive insulin therapy in type 1 diabetes is based on the well-established practice of adjusting basal and bolus insulin independently. Basal insulin delivery is designed to optimize glucose concentrations between ...
[EN] Since the early 2000s, there has been an exponentially increasing development of new diabetes-applied technology such as continuous glucose monitoring, bolus calculators, and "smart" pumps, with the expectation of ...
Leal, Yenny; GONZALEZ-ABRIL, LUIS; Lorencio, Carol; Bondía Company, Jorge; Vehí, Josep(Institute of Electrical and Electronics Engineers, 2013-07)
[EN] Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a ...
[EN] Many problems are confronted when characterizing a type 1 diabetic patient such as model mismatches, noisy inputs, measurement errors and huge variability in the glucose profiles. In this work we introduce a new ...
[EN] Background
Identification of individualized models for patients with type 1 diabetes is of vital importance for the development of a successful artificial pancreas and other model-based strategies of insulin treatment. ...
[EN] Objective:
Set-inversion-based prandial insulin delivery is a new model-based bolus advisor for postprandial glucose control in type 1 diabetes mellitus (T1DM). It automatically coordinates the values of basal-bolus ...
[EN] The aim of this study was to apply a methodology based on compositional data analysis (CoDA) to categorise glucose profiles obtained from continuous glucose monitoring systems. The methodology proposed considers ...
[EN] Background
Minimizing excessive postprandial glucose excursion is still an unmet need in treating diabetes. This work addresses the analysis and modeling in the postprandial state of two commercial CGM devices.
...
[EN] The artificial pancreas (AP) system is designed to regulate blood glucose in subjects with type 1 diabetes using a continuous glucose monitor informed controller that adjusts insulin infusion via an insulin pump. ...