Cañizares Ledo, Gabriel(Universitat Politècnica de València, 2022-07-28)
[ES] Desde su creación en la década de 1950, las imágenes tomográficas han resultado muy valiosas en el ámbito médico ayudando tanto en el diagnóstico como en el tratamiento de múltiples enfermedades. Dentro de la imagen ...
González, A.; Sánchez, F.; Martí, Rosana; Hernández Hernández, Liczandro; Aguilar-Talens, Albert; BARBERA BALLESTER, JULIO; CATRET MASCARELL, JUAN VICENTE; Cañizares-Ledo, Gabriel; Conde-Castellanos, Pablo Eloy; Lamprou, Efthymios; Martos Pedrosa, Francisco; Sánchez-Góez, Sebastián; Vidal San Sebastian, Luis Fernando; Benlloch Baviera, Jose María; González Martínez, Antonio Javier(Elsevier, 2018-12-21)
[EN] Organ dedicated PET devices provide improved imaging performance when compared to whole body systems. The present study summarizes the test carried out to study a new detector block designed for an organ dedicated PET ...
[EN] There are drawbacks with using a Positron Emission Tomography (PET) scanner design employing the traditional arrangement of multiple detectors in an array format. Typically PET systems are constructed with many regular ...
Cañizares, Gabriel; Espinós-Morató, Héctor; Santos, Joaquín; Hernández, Ángel; Moliner, Laura; Álvarez-Gómez, Juan Manuel; González Martínez, Antonio Javier; Sánchez, F; Rodríguez-Álvarez, MJ.; Benlloch Baviera, Jose María(IEEE, 2019-11-02)
[EN] Motion correction algorithms are necessary in PET studies where the patient cannot remain totally static. Otherwise, artifacts appear in the final reconstructed image, degrading the spatial resolution or even misplacing ...
González, A.; Sanchez, Filomeno; Bruyndonckx, Peter; Cañizares-Ledo, Gabriel; Benlloch Baviera, Jose María; González Martínez, Antonio Javier(Elsevier, 2019-03-11)
[EN] The main aim of this work is to provide a method to retrieve the intrinsic spatial resolution of a gamma-ray detector block based on monolithic crystals within an assembled scanner. This method consists on a discrimination ...
Lamprou, Efthymios; Aguilar -Talens, Albert; Gonzalez-Montoro, Andrea; Monzó Ferrer, José María; Cañizares-Ledo, Gabriel; Iranzo-Egea, Sofía; Vidal San Sebastian, Luis Fernando; Hernández Hernández, Liczandro; Conde-Castellanos, Pablo Eloy; Sánchez-Góez, Sebastián; Sanchez, Filomeno; González Martínez, Antonio Javier; Benlloch Baviera, Jose María(Elsevier, 2018-12-21)
[EN] In this contribution, large SiPM arrays (8 x 8 elements of 6 x 6 mm(2) each) are processed with an ASIC-based readout and coupled to a monolithic LYSO crystal to explore their potential use for TOF-PET applications. ...
Cañizares-Ledo, Gabriel; Gonzalez-Montoro, Andrea; Freire, Marta; Lamprou, Efthymios; Barrio, John; Sánchez Martínez, Filomeno; Benlloch Baviera, Jose María; Hernandez, Liczandro; Moliner, Laura; Vidal San Sebastian, Luis Fernando; Torres, Irene; Sopena, Pablo; Vera-Donoso, Cesar D.; Bello, Pilar; Barbera, Julio; González Martínez, Antonio Javier(SpringerOpen (part of Springer Nature), 2020-06-05)
[EN] Background: Prostate cancer (PCa) represents one of the most common types of
cancers facing the male population. Nowadays, to confirm PCa, systematic or
multiparametric MRI-targeted transrectal or transperineal ...
[EN] Recently, two novel PET devices have been developed with open geometries, namely: breast and prostate-dedicated scanners. The breast-dedicated system comprises two detector rings of twelve modules with a field of view ...