Pons Llinares, Joan; Antonino Daviu, José Alfonso; Riera-Guasp, Martín; Lee, Sang Bin; Kang, Tae-june; Yang, Chanseung(Institute of Electrical and Electronics Engineers (IEEE), 2015-03)
Transient-based fault diagnosis in induction
motors has gained increasing attention over the recent
years. This is due to its ability to avoid eventual wrong
diagnostics of the conventional motor current signature
analysis ...
Antonino-Daviu, J.; Pons Llinares, Joan; Lee, Sang Bin(Institute of Electrical and Electronics Engineers, 2016)
[EN] Anumber of field case studies for rotor fault diagnosis on medium-voltage induction motors operating in a petrochemical plant are presented in this paper. The methodology employed is based on analyzing the induction ...
Antonino-Daviu, J.; Riera-Guasp, Martín; Pons Llinares, Joan; Park, Jongbin; Lee, Sang Bin; Yoo, Jiyoon; Kral, Christian(Institute of Electrical and Electronics Engineers, 2012)
[EN] Unlike single-cage rotor fault detection, fast Fourier transform (FFT)-based steady-state spectrum analysis techniques can fail to detect outer-cage faults in double-cage induction motors due to the small outer-cage ...
Muhammad Faizan Shaikh; Park, Jongsan; Park, Yonghyun; Antonino-Daviu, J.; Lee, Sang Bin(Institute of Electrical and Electronics Engineers, 2022-07)
[EN] Broken damper bars and shorted field winding
turns degrade the starting and running performance of
industrial wound field synchronous motors (WFSMs), and can
lead to a forced outage of the motor and driven process. ...
Antonino-Daviu, J.; Lee, Sang Bin; Strangas, Elias(Institute of Electrical and Electronics Engineers, 2017)
[EN] With the expansion of the use of electrical drive sys-
tems to more critical applications, the issue of reliability and fault
mitigation and condition-based maintenance have consequently
taken an increasing importance: ...
Yang, Chanseung; Kang, Tae-June; Hyun, Doosoo; Lee, Sang Bin; Antonino Daviu, José Alfonso; Pons Llinares, Joan(Institute of Electrical and Electronics Engineers (IEEE), 2014-08)
Axial cooling air ducts in the rotor of large induction motors are known to produce magnetic asymmetry and can cause steady-state current or vibration spectrum analysis based fault detection techniques to fail. If the ...