Muhammad Faizan Shaikh; Park, Jongsan; Park, Yonghyun; Antonino-Daviu, J.; Lee, Sang Bin(Institute of Electrical and Electronics Engineers, 2022-07)
[EN] Broken damper bars and shorted field winding
turns degrade the starting and running performance of
industrial wound field synchronous motors (WFSMs), and can
lead to a forced outage of the motor and driven process. ...
Park, Yonghyun; Jeong, Myung; Sang Bin Lee; Antonino-Daviu, J.; Teska, Mike(Institute of Electrical and Electronics Engineers, 2017)
[EN] Motor current signature analysis (MCSA) has
recently become widespread in industry for on-line detection of
rotor cage faults in induction motors for preventing forced
outages. Although it can provide low cost, ...