[EN] Herein we present a diffractometric immunosensor to quantify low molecular weight organic compounds in a label-free, simple, and sensitive fashion. The approach is based on patterning analyte analogues (haptens) on ...
[EN] A sensitive, simple and label-free immunosensor for atrazine detection was developed. The immunosensor was based on antibody physisorption as immobilization technique. This technique was proposed as a cost-effective ...
Cases Iborra, Francisco Javier; Bonastre Cano, José Antonio; Orts Maiques, Francisco José; Khenifi, Aicha; Hamous, Hanene(Universitat Politècnica de ValènciaElsevier, 2022-03-01)
[EN] This study examines the degradation of atrazine (ATZ) with Pt-modified textile electrodes using an electrochemical method that is comparatively studied in two electrochemical cell configurations: cells with separated ...
The potential toxicity of pesticide residues in drinking water has
meant a rigid regulation for the appearance of these pollutants. Thus, in this
work, we developed a new immunosensor for atrazine detection. We focused ...
Hamous, Hanene; Khenifi, Aicha; Orts Maiques, Francisco José; Bonastre Cano, José Antonio; Cases, Francisco(Elsevier, 2022-03)
[EN] This study examines the degradation of atrazine (ATZ) with Pt-modified textile electrodes using an electrochemical method that is comparatively studied in two electrochemical cell configurations: cells with separated ...