[EN] Concrete exposed to fire can experience spalling when the pore pressure increases due to water evaporation resulting in damage to part of the concrete cross-section which causes the loss of the initial cross-sectional ...
La siguiente aplicación permite determinar los movimientos y esfuerzos dentro de y fuera del plano, y la capacidad resistente de las arcos comprimidos y flectados con sección en doble te, susceptibles de pandear en el plano ...
Goode, Charles(Editorial Universitat Politècnica de València, 2018-06-05)
[EN] The database of 1819 tests on concrete-filled steel tube columns was reported in 2008 [1,2] and covered all tests traced by the author up to 2007. This paper reports on 473 more tests carried out by 26 researchers ...
Muñoz Molina, Alejandro(Universitat Politècnica de València, 2018-05-21)
[ES] Glifosato es un herbicida no selectivo, que actúa inhibiendo la ruta de acción del ácido
shikimico en plantas. En el suelo, esta molécula se inmoviliza debido a que se adsorbe
fuertemente a coloides del suelo, en ...
Bonet Senach, José Luís; Romero, Manuel L.; Miguel Sosa, Pedro(Elsevier, 2011-03)
Most of the design codes (ACI-318-2008 and Euro Code-2-2004) propose the moment magnifier method in order to take into account the second order effect to design slender reinforced concrete columns. The accuracy of this ...
Peña Mansilla, David Leonardo(Universitat Politècnica de València, 2018-10-16)
En el presente trabajo final de máster (TFM), se estudiará el comportamiento de columnas de sección rectangular de hormigón armado ante la acción accidental del fuego. Específicamente se estudiará este tipo de sección y ...
BARRERA PUERTO, ANGELA; Bonet Senach, José Luís; Romero, Manuel L.; Miguel Sosa, Pedro(Elsevier, 2011-12)
The use of high strength concrete (HSC) in columns has become more frequent since a substantial reduction of the cross-section is obtained, meaning that slenderness increases for the same axial load and length, producing ...
[EN] A thorough analysis of slender columns under axial force and bending moment requires second order effects assessment. Concrete s creep is one of the factors that increase lateral displacements of the bar in the long ...
[EN] This article shows the influence of axial force eccentricity on high strength concrete columns design. The behavior of columns made of normal, middle and high strength concrete with slenderness values between 20 and ...
[EN] Because of its computational efficiency, simplified numerical modelling is the preferred method to simulate structural frames for routine design. As for concrete-filled steel tubular (CFST) columns, fibre beam element ...
[EN] Concrete-filled steel tubular (CFST) columns are composite sections that may contribute to reduce the envi-ronmental impact in construction through a more efficient use of resources. By embedding a steel profile inside ...
Cortés Moreno, Eduardo; Bonet Senach, José Luís; Romero, Manuel L.; Miguel Sosa, Pedro(Elsevier, 2011-02-03)
Most design codes (Model Code 90, ACI-318-2008 and Eurocode-2-2004) suggest that the effect of a geometrical imperfection ought to be taken into account in the most unfavorable direction when designing slender reinforced ...