Zhang, Qingjie; Schäfer, Markus(Editorial Universitat Politècnica de València, 2018-06-05)
[EN] This paper compares the design of composite columns in steel and concrete based on EN1994-1-1 and Chinese JGJ138-2016. First, the application ranges of the codes are pointed out. Both codes contain the design of fully ...
Huang, Zhenyu; Huang, Xinxiong; Li, Weiwen; Zhou, Yingwu; Sui, Lili; Liew, J. Y.(Editorial Universitat Politècnica de València, 2018-06-05)
[EN] A type of cost-effective and very high strength concrete (VHSC) with 28-day compressive strength of 100-150 MPa is developed for applications in concrete-encased steel composite column constructions. This paper ...
Portoles, J.M.; Romero, Manuel L.; Bonet Senach, José Luís; Filippou, F.C.(Elsevier, 2011-04)
The paper describes 37 tests conducted on slender circular tubular columns filled with normal and high strength concrete subjected to eccentric axial load. The test parameters were the nominal strength of concrete (30, 70 ...
[EN] The current EN 1992 provides structured information related to the design of reinforced concrete columns or reinforced concrete column beam connections. On the other hand, EN 1994 gives enough information on the design ...
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength ...
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength ...
Portoles Flaj, José Manuel; Serra Mercé, Enrique; Romero, Manuel L.(Elsevier, 2013-07)
This paper describes 24 tests conducted on slender circular tubular columns filled with normal, high, and ultra-high strength concrete for plain, bar reinforced and steel fiber reinforced columns. These were reinforced and ...
Sulthana, U. Mashudha; Jayachandran, S. Arul(Editorial Universitat Politècnica de València, 2018-06-05)
[EN] Concrete-Filled Double-skinned Steel Tubular columns (CFDST) are proved to possess exceptional structural resistance in case of fire and multi-hazard situations. This superior quality of CFDST makes it preferable in ...
Portoles Flaj, José Manuel; Romero, Manuel L.; Filippou, Filip C.; Bonet Senach, José Luís(Elsevier, 2011-05)
This paper proposes an efficient numerical model for the simulation of the behavior of slender circular
concrete-filled tubular columns subjected to eccentric axial load with single curvature, for the cases of
both normal ...
Hernández Figueirido, David; Romero, Manuel L.; Bonet Senach, José Luís; Montalva Subirats, José Miguel(Elsevier, 2012-01)
The paper describes 36 experimental tests conducted on rectangular and square tubular columns filled with normal and high strength concrete and subjected to a non-constant bending moment distribution with respect to the ...