[EN] Continuous Glucose Monitoring (CGM) has been a springboard of new diabetes management technologies such as integrated sensor-pump systems, the artificial pancreas, and more recently, smart pens. It also allows patients ...
[EN] Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes ...
Cuerda del Pino, Alba; Rodrigo Martín-San Agustín; Diez, José-Luís; Laguna Sanz, Alejandro José; Palanca, Ana; Rossetti, Paolo; Gumbau-Gimenez, Maria; Ampudia-Blasco, Francisco Javier; Bondía Company, Jorge(Mary Ann Liebert, 2024-06-01)
[EN] Background: This study aimed to evaluate the accuracy of Dexcom G6 (DG6) and FreeStyle Libre-2 (FSL2) during aerobic training and high-intensity interval training (HIIT) in individuals with type 1 diabetes. Methods: ...
[EN] Background and objectives : The adoption in clinical practice of electronic portable blood or interstitial glucose monitors has enabled the collection, storage, and sharing of massive amounts of glucose level readings. ...
Leal, Yenny; GONZALEZ-ABRIL, LUIS; Lorencio, Carol; Bondía Company, Jorge; Vehí, Josep(Institute of Electrical and Electronics Engineers, 2013-07)
[EN] Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a ...
[EN] Current Continuous Glucose Monitors (CGM) exhibit increased estimation error during periods of aerobic physical activity. The use of readily-available exercise monitoring devices opens new possibilities for accuracy ...
[EN] Background:
Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances ...
[EN] The aim of this study was to apply a methodology based on compositional data analysis (CoDA) to categorise glucose profiles obtained from continuous glucose monitoring systems. The methodology proposed considers ...
[EN] Background The endoscopically implanted duodenal-jejunal bypass liner (DJBL) is an attractive alternative to bariatric surgery for obese diabetic patients. This article aims to study dynamical aspects of the glycaemic ...
Barceló Rico, Fátima(Universitat Politècnica de València, 2012-09-20)
ABSTRACT
Diabetes Mellitus (DM) embraces a group of metabolic diseases which main characteristic is the presence of high glucose levels in blood. It is one of the diseases with major social and health impact, both for its ...
[EN] Background
Minimizing excessive postprandial glucose excursion is still an unmet need in treating diabetes. This work addresses the analysis and modeling in the postprandial state of two commercial CGM devices.
...
This paper introduces a data-driven methodology for detecting therapeutically correct and incorrect
measurements in continuous glucose monitoring systems (CGMSs) in an intensive care unit (ICU). The
data collected from ...