Servicios adicionales en SFX(opens in a new window)|View at Publisher|
Export
| Download | Add to List | More...
Engineering Structures
Volume 108, February 01, 2016, Pages 12-27
A 3D finite element model for ...
[EN] Concrete exposed to fire can experience spalling when the pore pressure increases due to water evaporation resulting in damage to part of the concrete cross-section which causes the loss of the initial cross-sectional ...
Espinós Capilla, Ana; Romero García, Manuel Luis; Hospitaler Pérez, Antonio; Pascual Pastor, Ana María; Albero Gabarda, Vicente(Elsevier, 2015)
[EN] The advantages of concrete-filled steel tubular (CFST) columns are well known at room and elevated temperatures, however, beyond a certain slenderness their load-bearing capacity starts to decrease. Besides, blind-bolts ...
Espinós Capilla, Ana; Romero, Manuel L.; Hospitaler Pérez, Antonio(Elsevier, 2010-08)
In this work, a nonlinear finite element three-dimensional model is presented and validated in order to study the behaviour of axially loaded concrete filled tubular (CFT) columns with circular cross-section exposed to ...
Espinós Capilla, Ana; Romero, Manuel L.; Portolés Flag, Jose Manuel; Hospitaler Pérez, Antonio(Elsevier, 2014-09)
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete ...
[EN] Conservation of built heritage, at present, is a major task and a great challenge because it requires adapting the performance of existing buildings to current code requirements, when very often these were built before ...
García Castillo, Ester(Universitat Politècnica de València, 2025-07-30)
[ES] Los edificios históricos tienen un gran valor arquitectónico y cultural y son un bien muy preciado de nuestra civilización. Por ello, no es de extrañar que se hagan grandes esfuerzos para conservarlos. Sin embargo, a ...
García Castillo, Ester(Universitat Politècnica de València, 2019-10-17)
[EN] Numerous historic buildings have a structure formed by masonry or brick walls and flooring systems with timber joists and brick archies. Rehabilitating buildings with this structural system is a great challenge because ...
Ortega Latorre, Javier(Universitat Politècnica de València, 2015-07-27)
[EN] This Master's Thesis aims to address the behaviors of hollow core precast concrete made with different
reinforcement arrangement, although similar mechanical level and ultimate bending moment at room
temperature, ...
[EN] Demountable shear connectors are a key component of reusable structural systems. The intention behind the development of these systems is substituting, or at least providing a valid alternative to the widely utilized ...
Previous investigations have revealed the unsafety of the current calculation methods in Eurocode 4 for evaluating the fire resistance of concrete-filled steel tubular (CFST) columns, which has given place to a movement ...
[EN] In this paper, the behaviour of slender axially loaded square and circular CFT columns
exposed to fire is modelled using the finite element analysis package ABAQUS. A
realistic sequentially coupled nonlinear ...
Peña Mansilla, David Leonardo(Universitat Politècnica de València, 2023-02-24)
[ES] El hormigón es un material excelente para usar en proyectos estructurales por varias razones, siendo una de ellas su buen comportamiento en caso de incendio, debido a su incombustibilidad y baja difusividad térmica. ...
Jurado Boyero, Adrián(Universitat Politècnica de València, 2024-09-17)
[ES] El objetivo del presente Trabajo Final de Máster es el diseño y el cálculo de la estructura portante
de un edificio de oficinas de tres alturas situado en la localidad de Salamanca, con una superficie de
800 metros ...
[EN] In recent years, innovative solutions have been developed with the purpose of increasing
both the load-bearing capacity and fire resistance of concrete-filled steel tubular (CFST) columns.
One of these solutions are ...
Zheng Lu, Jia Wei(Universitat Politècnica de València, 2017-10-24)
[EN] The present document is a study about the fire resistance of an experimental structural element made in the campus of the Polytechnic University of Valencia. This structural element tries to resemble a composite bridge ...
Peña Mansilla, David Leonardo(Universitat Politècnica de València, 2018-10-16)
En el presente trabajo final de máster (TFM), se estudiará el comportamiento de columnas de sección rectangular de hormigón armado ante la acción accidental del fuego. Específicamente se estudiará este tipo de sección y ...
[EN] Composite construction is becoming increasingly used across the world, since it enables to exploit the benefits of steel and concrete working together, leading to costeffective solutions. Recent technological developments ...
While the fire behaviour of concrete-filled steel tubular (CFST) columns with circular and square cross-section has been well established based on experimental programs and numerical investigations, the information about ...
Albero, Vicente; Espinós, Ana; Serra, Enrique; Romero, Manuel L.; Hospitaler, Antonio(Editorial Universitat Politècnica de València, 2018-06-05)
[EN] Steel-concrete composite beams embedded in floors (slim-floors) offer various advantages such as the floor thickness reduction or the ease of installation of under-floor technical equipment. However, this typology ...