Tarazona Martínez, Alfonso; Gnanvo, K.; Martoiu, S.; Muller, H.; Toledo Alarcón, José Francisco(IOP Publishing: Hybrid Open Access, 2014-06)
Upgrades of the LHC detectors target significantly higher event rates and higher bandwidth
over point-to-point links. The Data, Trigger, Clock and Control (DTCC) is a new custom link protocol for data and control streams ...
Among the different techniques available, the SiPM power supply described in this paper uses output voltage and sensor temperature feedback. A high-resolution ADC digitizes both the output voltage and an analog signal ...
Aliaga Varea, Ramón José(Universitat Politècnica de València, 2016-05-02)
[EN] Positron Emission Tomography (PET) is a non-invasive nuclear medical imaging modality that makes it possible to observe the distribution of metabolic substances within a patient's body after marking them with radioactive ...
Aliaga Varea, Ramón José; Herrero Bosch, Vicente; Monzó Ferrer, José María; Ros García, Ana; Gadea Gironés, Rafael; Colom Palero, Ricardo José(Institute of Electrical and Electronics Engineers (IEEE), 2014-02)
A DAQ architecture for a PET system is presented that focuses on modularity, scalability and reusability. The system defines two basic building blocks: data acquisitors and concentra- tors, which can be replicated in order ...
Esteve Bosch, Raul; Toledo Alarcón, José Francisco; Monrabal Capilla, Francesc; Lorca Galindo, David; Serra Diaz-Cano, Luis; Marí Romero, Antonio Francisco; Gómez Cadenas, Juan José; Liubarsky, Igor; Mora Mas, Francisco José(Institute of Physics: Hybrid Open Access, 2012-12)
[EN] NEXT-DEMO is a prototype of NEXT (Neutrino Experiment with Xenon TPC), an
experiment to search for neutrino-less double beta decay using a 100 kg radio-pure, 90 % enriched (136Xe isotope) high-pressure gaseous xenon ...