[EN] The present work focuses on the analysis of nuclear reactions that can occur in a cyclotron for the generation of radionuclides compliant with the restrictions necessary for medical use in a PET. These radionuclides ...
Machado Cervera, Claudia Amparo(Universitat Politècnica de València, 2018-09-12)
El presente Trabajo Fin de Grado (TFG) tiene como principal objetivo analizar aspectos de
protección radiológica aplicados a una sala en la que se manipulan radioisótopos líquidos no
encapsulados. Debido a los riesgos ...
Torres Castillo, Isaac(Universitat Politècnica de València, 2024-07-29)
[ES] Este proyecto consiste en un análisis neutrónico de un pequeño reactor modular (SMR)
desarrollado por la empresa estadounidense NuScale Power, cuyo diseño se basa en un reactor de
agua a presión (PWR) compuesto por ...
Camarelles Pérez, Pedro(Universitat Politècnica de València, 2024-10-29)
[ES] El presente trabajo consiste en el análisis de la criticidad en una piscina de almacenamiento de
combustible nuclear. El análisis se realiza específicamente en la región de la piscina destinada a
almacenar elementos ...
Jabaloyas Cases, Eva(Universitat Politècnica de València, 2021-06-02)
[ES] La Tomografía por Emisión de Positrones (PET) es una técnica no invasiva utilizada para la evaluación del funcionamiento de órganos y tejidos, a partir de la administración de radiofármacos al sujeto de estudio. ...
Pastor Serrano, Óscar(Universitat Politècnica de València, 2016-07-15)
[ES] El objetivo de este proyecto es la validación del modelo de MCNP del reactor VENUS con
datos obtenidos experimentalmente. Posteriormente a la validación, se realizarán cálculos de
quemado para ver la evolución de ...
Ródenas Diago, José; Gallardo Bermell, Sergio(Sociedad Española de Física Médica, 2011)
[ES] Las barras de control de un reactor de agua en ebullición (BWR) están sometidas a un flujo neutrónico y por tanto, resultan
activadas durante su permanencia en el núcleo del reactor. La activación se produce especialmente ...
[ES] En este trabajo se propone el uso de un detector flat panel junto a una cuña de polimetilmetacrilato (PMMA) para estimar el espectro de rayos X utilizando el método de Monte Carlo y técnicas de reconstrucción. El ...
All materials present in the core of a nuclear reactor are activated by neutron irradiation. The activity so
generated produces a dose around the material. This dose is a potential risk for workers in the
surrounding ...
Obtaining primary X-ray spectra is a complex task mainly due to the high fluence of X-rays. In order to avoid the pile up effect in the detector, an indirect method based on the Compton scattering interactions in a low ...
An accurate knowledge of the photon spectra emitted by X-ray tubes in radiodiagnostic is essential to
better estimate the imparted dose to patients and to improve the quality image obtained with these
devices. In this ...
[EN] Quality control of mammography units is necessary
to reduce the dose imparted to women as much as possible. Accurate characterization of the primary X-ray
spectra is very useful for this purpose. Obtaining primary ...
[EN] Purpose: The purpose of this study is to validate the PenRed Monte Carlo framework for clinical applications in brachytherapy. PenRed is a C++ version of Penelope Monte Carlo code with additional tallies and ...
Giubrone, Giuseppe; Ortiz Moragón, Josefina; Gallardo Bermell, Sergio; Martorell Alsina, Sebastián Salvador; Bas Cerdá, María del Carmen(Elsevier, 2016-07)
[EN] The aim of this paper was to calculate the True Coincidence Summing Correction Factors (TSCFs) for an HPGe coaxial detector in order to correct the summing effect as a result of the presence of Y-88 and Co-60 in a ...
Morera Cano, Daniel(Universitat Politècnica de València, 2013-03-26)
[ES] El presente trabajo tiene como objetivodesarrollar una metodología para realizar una calibración espacial de la señal de EPID obteniendo así la distribución de dosis por medio de simulaciones Monte Carlo. Esta calibración ...
Lacasta Soto, Asier; Morales-Hernández, M.; Tejero-Juste, M.; Burguete, J.; Brufau, P.; García-Navarro, P.(Editorial Universitat Politècnica de València, 2015-07-27)
[EN] Channel flow covers long distances and obeys to variable temporal behaviour. It is usually regulated by hydraulic elements as lateral gates to provide a correct of water supply. The dynamics of this kind of flow is ...
Ramos Ballester, María Amparo(Universitat Politècnica de València, 2023-09-08)
[ES] El presente Trabajo Fin de Grado (TFG) tiene por objeto caracterizar un detector de Germanio y un detector de Yoduro de sodio con diferentes códigos de Monte Carlo para obtener la curva de calibración en eficiencias ...
Calero Gómez, Patricia(Universitat Politècnica de València, 2021-03-22)
[ES] En los tratamientos de radioterapia intraoperatoria se hace uso de aceleradores de partículas para suministrar haces de electrones o Rayos X en el lecho tumoral durante la intervención
quirúrgica de eliminación del ...
Morejón Cebrián, Rodrigo(Universitat Politècnica de València, 2020-10-14)
[ES] El objetivo de este proyecto es la ratificación del código Monte Carlo MCNP6, para la
simulación del transporte neutrónico en un reactor comercial PWR del tipo KWU, utilizando una
malla no estructurada. En concreto, ...
Mengod Bautista, Fernando(Universitat Politècnica de València, 2016-10-07)
[ES] El presente trabajo tiene como objetivo el cálculo y estudio dosimétrico de un sistema de
almacenamiento de combustible nuclear gastado. Para llevar a cabo este cometido se emplean
códigos de transporte, en concreto ...