This paper analyses the valuable information provided by the on-line measurements of pH and oxidation reduction potential (ORP) in a continuous single high ammonia removal over nitrite (SHARON) reactor. A laboratory-scale ...
This paper presents a real-time control strategy for nitrogen removal via nitrite in a continuous flow SHARON reactor using on-line available and industrially feasible sensors (pH and ORP). The developed control strategy ...