Spaggiari, Michele; Herrero Bosch, Vicente; Lerche, Christoph Werner; Aliaga Varea, Ramón José; Monzó Ferrer, José María; Gadea Gironés, Rafael(IOP Publishing: Hybrid Open Access, 2011-01)
In this article we introduce AMIC (Analog Moments Integrated Circuit), a novel analog Application Specific Integrated Circuit (ASIC) front-end for Positron Emission Tomography (PET) applications. Its working principle is ...
Monzó Ferrer, José María; Ros García, Ana; Herrero Bosch, Vicente; Perino Vicentini, Ivan Virgilio; Aliaga Varea, Ramón José; Gadea Gironés, Rafael; Colom Palero, Ricardo José(IOP Publishing: Hybrid Open Access, 2013-03)
[EN] Improving timing resolution in positron emission tomography (PET), thus having fine time information of the detected pulses, is important to increase the reconstructed images signal to noise ratio (SNR) [1]. In the ...
[EN] New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as ...
Monzó Ferrer, José María; Aguilar -Talens, Albert; González Montoro, Andrea; Lamprou,E.; González Martínez, Antonio Javier; Hernández Hernández, Liczandro; Mázur, Dmytro; Colom Palero, Ricardo José; Benlloch Baviera, Jose María(IOP Publishing, 2017)
[EN] Developing front-end electronics to improve charge detection and time resolution in gamma-ray detectors is one of the main tasks to improve performance in new multimodal imaging systems that merge information of ...
Herrero Bosch, Vicente; Monzó Ferrer, José María; Ros García, Ana; Aliaga Varea, Ramón José; González Martínez, Antonio Javier; Montoliu, C.; Colom Palero, Ricardo José; Benlloch Baviera, Jose María(IOP Publishing: Hybrid Open Access, 2012-12)
[EN] AMIC architecture has been introduced in previous works in order to provide a generic and expandable solution for implementing large number of outputs SiPM array/PMT detectors. The underlying idea in AMIC architecture ...
Ros, A.; Lerche, Christoph Werner; Sebastia Cortes, Angel; Sanchez, F.; Benlloch Baviera, Jose María(IOP Publishing, 2014-04)
A method to improve light collection efficiency of γ-ray imaging detectors by using
retroreflector arrays has been tested, simulations of the behaviour of the scintillation light illuminating
the retroreflector surface ...
[EN] Recently, two novel PET devices have been developed with open geometries, namely: breast and prostate-dedicated scanners. The breast-dedicated system comprises two detector rings of twelve modules with a field of view ...