Mier Escurra, Christian; Rodrigo Mor, Armando; Vaessen, Peter(Institute of Electrical and Electronics Engineers, 2021-09-01)
[EN] A recent investigation explored a new measuring concept used in partial discharges (PD) measurements in gas insulated substations (GIS), consisting of a magnetic loop antenna. The sensor¿s frequency response was ...
Ferrer Redondo, Ana Belén(Universitat Politècnica de València, 2021-10-08)
[ES] En el presente trabajo se recoge de manera descriptiva un estudio sobre las descargas parciales en el sistema de aislamiento de los motores eléctricos como método para controlar el estado en el que se encuentra el ...
Rodrigo Mor, Armando; Llovera Segovia, Pedro; Fuster Roig, Vicente Luis; Quijano Lopez, Alfredo(Institute of Electrical and Electronics Engineers (IEEE), 2013-04)
[EN] Partial discharge (PD) cable field tests require the use of high frequency sensors
coupled to the cable for PD apparent charge evaluation. PD sensors can be coupled to
the cable by magnetic field, like high frequency ...
Rodrigo Mor, Armando; Llovera Segovia, Pedro; Fuster Roig, Vicente Luis; Quijano Lopez, Alfredo(Institute of Electrical and Electronics Engineers (IEEE), 2011-10)
[EN] High frequency current transformers (HFCT) are now widely used for partial discharges detection and measurement, specially for partial discharge location and source identification. However, many difficulties arise due ...
[EN] In Power Systems, SG are mostly used for generating electricity. Their insulation system, of which epoxy resin is a core component, plays a significant role reliable operation. Epoxy resin has high mechanical strength, ...
Rodrigo Mor, Armando; Morshuis, P. H. F.; Llovera Segovia, Pedro; Fuster Roig, Vicente Luis; Quijano Lopez, Alfredo(Institute of Electrical and Electronics Engineers (IEEE), 2016-03)
Partial discharge (PD) field tests are widely used for cable assessment or cable commissioning. Usually, these tests are carried out by means of off-line tests where PD pulses are measured with capacitively coupled PD ...
[EN] There are no accepted procedures that quantify the apparent charge of partial discharge (PD) in gas-insulated substations (GIS). This paper proposes a calibration method for PD charge estimation using unconventional ...
[EN]
One of the main difficulties in measuring partial discharges (PD) in gas-insulated substations (GIS) is the overlapping of pulses at the sensor's location, which distorts the pulse resolution and the charge estimation. ...
[EN]
On-site partial discharge (PD) measurements have turned out to be a very efficient technique for determining the insulation condition in high-voltage electrical grids (AIS, cable systems, GIS, HVDC converters, etc.); ...
Rodrigo Mor, Armando; Llovera Segovia, Pedro; Fuster Roig, Vicente Luis; Quijano Lopez, Alfredo(Institute of Electrical and Electronics Engineers (IEEE), 2012-04)
[EN] High frequency current transformers (HFCT) are widely used in partial discharge field and laboratory tests. Using these devices as sensors in partial discharge cable tests brings some advantages, namely: high degree ...