Freire, Marta; Gonzalez-Montoro, Andrea; Sánchez Martínez, Filomeno; Benlloch Baviera, Jose María; González Martínez, Antonio Javier(Institute of Electrical and Electronics Engineers, 2020-05)
[EN] Molecular imaging systems, such as positron emission tomography (PET), use detectors providing energy and a 3-D interaction position of a gamma ray within a scintillation block. Monolithic crystals are becoming an ...
Shepherd, Tony; Teräs, Mika; Beichel, Reinhard R.; Boellaard, Ronald; Bruynooghe, Michel; Dicken, Volker; Gooding, Mark J.; Julyan, Peter J.; Lee, John A.; Lefèvre, Sébastien; Mix, Michael; Naranjo Ornedo, Valeriana; Wu, Xiaodong; Zaidi, Habib; Zeng,Ziming; Minn, Heikki(Institute of Electrical and Electronics Engineers (IEEE), 2012-11)
[EN] The impact of positron emission tomography (PET)
on radiation therapy is held back by poor methods of defining functional
volumes of interest. Many new software tools are being proposed
for contouring target volumes ...
Lamprou, Efthymios(Universitat Politècnica de València, 2021-03-04)
[ES] La Tomografía por Emisión de Positrones (PET) es una de las técnicas más importantes en la medicina de diagnóstico actual y la más representativa en el campo de la Imagen Molecular. Esta modalidad de imagen es capaz ...
Aliaga Varea, Ramón José(Universitat Politècnica de València, 2016-05-02)
[EN] Positron Emission Tomography (PET) is a non-invasive nuclear medical imaging modality that makes it possible to observe the distribution of metabolic substances within a patient's body after marking them with radioactive ...
González Martínez, Antonio Javier; González-Montoro, Andrea(2024-01)
[EN] Some specific MI designs assessing early detection and staging of PCa have been proposed. It can be differentiated between systems (dedicated-, WB-and TB-PET), and inserts or probes that are placed much closer to the ...
Monzó Ferrer, José María; Esteve Bosch, Raul; Lerche, Christoph Werner; Ferrando Jódar, Néstor; Toledo Alarcón, José Francisco; Aliaga Varea, Ramón José; Herrero Bosch, Vicente; Mora Mas, Francisco José(Institute of Electrical and Electronics Engineers (IEEE), 2011-08)
Coincidence time resolution is one of the most important issues in PET detectors. Improving this resolution is required to increase the noise equivalent count rate (NECR) that reduces the noise in the reconstructed images. ...
Aliaga Varea, Ramón José; Herrero Bosch, Vicente; Monzó Ferrer, José María; Ros García, Ana; Gadea Gironés, Rafael; Colom Palero, Ricardo José(Institute of Electrical and Electronics Engineers (IEEE), 2014-02)
A DAQ architecture for a PET system is presented that focuses on modularity, scalability and reusability. The system defines two basic building blocks: data acquisitors and concentra- tors, which can be replicated in order ...
Álvarez-Gómez, Juan Manuel; Santos-Blasco, Joaquín; Moliner Martínez, Laura; Rodríguez-Álvarez, María José(MDPI AG, 2021-10)
[EN] Improvements in energy resolution of modern positron emission tomography (PET) detectors have created opportunities to implement energy-based scatter correction algorithms. Here, we use the energy information of ...
Lecoq, P.; González Martínez, Antonio Javier; Auffray, E.; Konstantinou, G.; Nuyts, J.; Prior, J. O.; Turtos, R. M.; Varela, J.(Institute of Electrical and Electronics Engineers, 2023-05)
[EN] We report in this article on the Fast Timing in Medical Imaging workshop, (Valencia, 2 June 2022). The workshop gathered 104 attendees from all over the world, with representatives from the academic and industrial ...
Lecoq, Paul; Konstantinou, Georgios; Latella, Riccardo; Moliner Martínez, Laura; Nuyts, Johan; Zhang, Lei; Barrio, John; Benlloch Baviera, Jose María; González Martínez, Antonio Javier(Institute of Electrical and Electronics Engineers, 2022-05)
[EN] We report on the progress on a first generation of
realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved
with fast scintillator layers producing ...
Aliaga Varea, Ramón José; Monzó Ferrer, José María; Spaggiari, Michele; Ferrando Jódar, Néstor; Gadea Gironés, Rafael; Colom Palero, Ricardo José(Institute of Electrical and Electronics Engineers (IEEE), 2011-08)
Current PET systems with fully digital trigger rely on early digitization of detector signals and the use of digital processors, usually FPGAs, for recognition of valid gamma events on single detectors. Timestamps are ...
Konstantinou, Georgios; Zhang, Lei; Bonifacio, Daniel; Latella, Riccardo; Benlloch Baviera, Jose María; González Martínez, Antonio Javier; Lecoq, Paul(Institute of Electrical and Electronics Engineers, 2024-05)
[EN] In this study, we propose and examine a unique semimonolithic metascintillator (SMMS) detector design, where slow scintillators (BGO or LYSO) are split into thin slabs and read by an array of SiPM, offering ...
Aguilar, A.; González Martínez, Antonio Javier; Torres, J.; García Olcina, Raimundo; Martos, J.; Soret, J.; Conde Castellanos, Pablo Eloy; Hernández Hernández, Liczandro; Sanchez, F.; Benlloch Baviera, Jose María(Institute of Electrical and Electronics Engineers (IEEE), 2015-02)
Silicon photomultipliers (SiPMs) have become an alternative to traditional tubes due to several features. However, their implementation to form large arrays is still a challenge especially due to their relatively high ...