[EN] This paper addresses a study of cost-optimal road modular hinged frames. The performance of three hybrid metaheuristics is assessed through a fractional factorial design of experiments. The results allow for selecting ...
Germanà, Maria Luisa(Universitat Politècnica de València, 2023-05-11)
[EN] Maintenance concerns most of the artifacts, referring simultaneously to the socio-cultural, technical and managerial spheres. Contemporary scenarios impose an overall rethinking, where key-topics such as tradition, ...
Meléndez-Gimeno, Carlos; Miguel Sosa, Pedro; Pallarés Rubio, Luis(Elsevier, 2016-09)
Several advanced constitutive models of concrete have been developed in recent decades, some of which are able to reproduce the behaviour of concrete structures with a high level of accuracy. Yet given their complex ...
Miguel Sosa, Pedro; Navarro-Gregori, Juan; Fernández Prada, Miguel Ángel; Bonet Senach, José Luís(Elsevier, 2013-04)
This paper presents a new simplified verification method to predict the ultimate shear stress and the
mode of failure of reinforced concrete membrane elements with orthogonal reinforcement under any
combination of normal ...
Arango Campo, Samuel Eduardo; Serna Ros, Pedro; Martí Vargas, José Rocío; García Taengua, Emilio José(Society for Experimental Mechanics, 2011)
[EN] This paper presents a proposal of test setup and methodology for testing the flexural creep behaviour of pre-cracked Fibre Reinforced Concrete (FRC) specimens, aimed at providing a basis for standardization. The design ...
Navarro-Gregori, Juan; Miguel Sosa, Pedro; Fernández Prada, Miguel Ángel; Martí Vargas, José Rocío(Elsevier, 2013-07)
This paper presents a model for the analysis of reinforced concrete beams under monotonic loading conditions, including axial, bending, and shear forces, in order to effectively capture the mechanisms of shear transfer. ...
[EN] Concrete exposed to fire can experience spalling when the pore pressure increases due to water evaporation resulting in damage to part of the concrete cross-section which causes the loss of the initial cross-sectional ...
Ramón, Jose Enrique; Martínez, Isabel; Gandía-Romero, Jose M.; Soto Camino, Juan(MDPI AG, 2021-04)
[EN] The concrete electrical resistivity is a prominent parameter in structural health monitoring, since, along with corrosion potential, it provides relevant qualitative diagnosis of the reinforcement corrosion. This study ...
Ortega, Irene; Pellicer, Teresa M.; Adam, Jose M; Calderón García, Pedro Antonio(Elsevier, 2018)
[EN] This paper describes a study carried out in the ICITECH laboratories (Universitat Politècnica de València) on RC columns repaired on all four sides with cementitious-based mortars. A total of 18 specimens were tested, ...
Rueda-García, Lisbel; Bonet Senach, José Luís; Miguel Sosa, Pedro; Fernández Prada, Miguel Ángel(Elsevier, 2021-11-01)
[EN] Precast concrete beams with cast-in-place slabs on top, namely concrete composite beams are frequently used for building concrete bridge decks. In designs, the contribution of cast-in-place slabs to shear strength ...
Mir Díaz, Carlos(Universitat Politècnica de València, 2024-02-19)
[ES] El entorno de la construcción es de obvia importancia para nuestro desarrollo sostenible, ya que no solo facilita la actividad social, sino que también tiene una participación importante en el volumen de negocios ...
[EN] Fire engineering endeavours to mitigate injury or the loss of life in the event of a fire. This
is achieved primarily through fire prevention, containment, and extinguishment measures. Should
prevention fail, the ...
Avendaño Vera, Constanza Camila(Universitat Politècnica de València, 2023-10-11)
[ES] Este trabajo tiene como objetivo principal realizar un análisis comparativo de tres sistemas constructivos tradicionales de la vivienda chilena y en cómo es afectada su durabilidad según la zona climática en que este ...
Aparisi López, Tatiana(Universitat Politècnica de València, 2021-01-25)
[ES] El objetivo del presente proyecto es la determinación de la influencia de la altura del muro en el coste monetario de un depósito circular de hormigón en función de que el diseño se haga con hormigón armado u hormigón ...
Uzqueda Pellejero, Miguel(Universitat Politècnica de València, 2020-09-22)
[ES] La vulnerabilidad de las construcciones frente a agentes externos, es un tema que cuenta con varias líneas de investigación. En el caso de la agresividad del ambiente costero, hay numerosos daños provocados por este ...
Blanco Duarte, Miguel Ángel(Universitat Politècnica de València, 2021-03-26)
[ES] Este trabajo experimental tiene como objetivo principal analizar los procesos de las corrientes de macrocelda en estructuras de hormigón armado, para poder así determinar su importancia en los procesos de corrosión ...
Martínez Jaén, Begoña(Universitat Politècnica de València, 2017-10-18)
[EN] The conventional seismic design approach used in recent years relies on the ability of structures to dissipate earthquake energy through inelastic deformations in specifically designed regions of the structural system, ...
Cabañero Escudero, Beatriz(Universitat Politècnica de València, 2017-10-18)
[EN] The conventional seismic design approach used in recent years relies on the ability of structures to dissipate earthquake energy through inelastic deformations in specifically designed regions of the structural system, ...
Esparcia Cañada, Francisco Rubén(Universitat Politècnica de València, 2019-01-31)
[ES] El siguiente trabajo tiene su origen en la fascinación por uno de los más importantes ingenieros de todos los tiempos, Eduardo Torroja Miret, a quien el propio Wright consideraba como el mejor ingeniero de su época. ...
Gonzalvo Moreno, Ricardo(Universitat Politècnica de València, 2020-12-03)
[ES] Debido a la gran influencia que tienen los sismos en el diseño de estructuras ubicadas en zonas sísmicas activas, como es el caso del Valle de México, se hace necesario disponer de las herramientas y conocimientos ...