Moscardi Malan, Ana Carolina(Universitat Politècnica de València, 2013-03-05)
[ES] Actualmente, los materiales metálicos más comúnmente utilizados como biomateriales son las aleaciones de cobalto y las aleaciones de base titanio. Sin embargo, existen algunas limitaciones y una tendencia a la de ...
Fernández Domene, Ramón Manuel; Blasco Tamarit, María Encarnación; García García, Dionisio Miguel; García Antón, José(Elsevier, 2011-12-30)
The cavitation corrosion behaviour of commercially pure Grade 2 titanium in a 992 g/l LiBr solution has been investigated at 25 °C using an ultrasound device. Cavitation was found to have more influence on the anodic branch ...