Serra, L.; Sorel, M.; Alvarez, V.; Borges, F. I. G.; Camargo, M.; Carcel, S.; Cebrian, S.; Cervera, A.; Conde, C. A. N.; Dafni, T.; Diaz, J.; Esteve Bosch, Raul; Marí Romero, Antonio Francisco; Mora Mas, Francisco José; Pérez Aparicio, José Luis; Querol Galve, Marcos; Toledo Alarcón, José Francisco; Webb, Rachel; Yahlali Haddou, Nadia(IOP Publishing, 2015-03)
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100
high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration
source. Compared to our previous measurements with ...
Lamprou, Efthymios(Universitat Politècnica de València, 2021-03-04)
[ES] La Tomografía por Emisión de Positrones (PET) es una de las técnicas más importantes en la medicina de diagnóstico actual y la más representativa en el campo de la Imagen Molecular. Esta modalidad de imagen es capaz ...
Lecoq, P.; González Martínez, Antonio Javier; Auffray, E.; Konstantinou, G.; Nuyts, J.; Prior, J. O.; Turtos, R. M.; Varela, J.(Institute of Electrical and Electronics Engineers, 2023-05)
[EN] We report in this article on the Fast Timing in Medical Imaging workshop, (Valencia, 2 June 2022). The workshop gathered 104 attendees from all over the world, with representatives from the academic and industrial ...
Lecoq, Paul; Konstantinou, Georgios; Latella, Riccardo; Moliner Martínez, Laura; Nuyts, Johan; Zhang, Lei; Barrio, John; Benlloch Baviera, Jose María; González Martínez, Antonio Javier(Institute of Electrical and Electronics Engineers, 2022-05)
[EN] We report on the progress on a first generation of
realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved
with fast scintillator layers producing ...
Rogers, L.; Jones, B. J. P.; Laing, A.; Pingulkar, S.; Smithers, B.; Woodruff, K.; Adams, C.; Álvarez-Puerta, Vicente; Arazi, L.; Arnquist, I. J.; Azevedo, C. D. R.; Bailey, K.; Ballester Merelo, Francisco José; Benlloch-Rodríguez, J. M.; Borges, F. I. G. M.; Esteve Bosch, Raul; Herrero Bosch, Vicente; Mora Mas, Francisco José; Rodriguez-Samaniego, Javier; Toledo Alarcón, José Francisco(IOP Publishing, 2020-07)
[EN] Xe-136 is used as the target medium for many experiments searching for 0 nu beta beta. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector ...
González Martínez, Antonio Javier; Majewski, Stanislaw; Barbera, J.; Conde Castellanos, Pablo Eloy; Correcher, C.; Hernández Hernández, Liczandro; Morera, C.; Vidal San Sebastián, Luis Fernando; Sánchez Martínez, Filomeno; Stolin, A.; Benlloch Baviera, Jose María(Institute of Electrical and Electronics Engineers (IEEE), 2015-02)
In this paper, the capabilities of a wide-area gamma ray photosensor based on a SiPM array are investigated. For this purpose, we have mounted an array of 144 SiPMs with individual active area of mm and a pitch of mm, thus ...
Freitas, E. D. C.; Fernandes, L. M. P.; Yahlali, N.; Perez, J.; Alvarez, V.; Borges, F. I. G.; Camargo, M.; Carcel, S.; Cebrian, S.; Esteve Bosch, Raul; Marí Romero, Antonio Francisco; Mora Mas, Francisco José; Pérez Aparicio, José Luis; Rodríguez Samaniego, Javier; Toledo Alarcón, José Francisco(IOP Publishing, 2015-02)
We have studied the calibration of PMTs in scintillation detectors, inducing single electron response on the PMT from primary scintillation produced by x-ray interaction. The results agree with those obtained by the commonly ...
Konstantinou, Georgios; Zhang, Lei; Bonifacio, Daniel; Latella, Riccardo; Benlloch Baviera, Jose María; González Martínez, Antonio Javier; Lecoq, Paul(Institute of Electrical and Electronics Engineers, 2024-05)
[EN] In this study, we propose and examine a unique semimonolithic metascintillator (SMMS) detector design, where slow scintillators (BGO or LYSO) are split into thin slabs and read by an array of SiPM, offering ...