[EN] Continuous Glucose Monitoring (CGM) has been a springboard of new diabetes management technologies such as integrated sensor-pump systems, the artificial pancreas, and more recently, smart pens. It also allows patients ...
Beneyto, Aleix; Bertachi, Arthur; Bondía Company, Jorge; Vehí, Josep(Institute of Electrical and Electronics Engineers, 2020-03)
[EN] The artificial pancreas (AP) system or closed-loop blood glucose (BG) regulation is a technological advancement that aims to relieve diabetic subjects from their current decision-making burden while tightening their ...
[EN] Continuous glucose monitoring (CGM) plays an important role in treatment decisions for patients with type 1 diabetes under conventional or closed-loop therapy. Physical activity represents a great challenge for diabetes ...
Cuerda del Pino, Alba; Rodrigo Martín-San Agustín; Diez, José-Luís; Laguna Sanz, Alejandro José; Palanca, Ana; Rossetti, Paolo; Gumbau-Gimenez, Maria; Ampudia-Blasco, Francisco Javier; Bondía Company, Jorge(Mary Ann Liebert, 2024-06-01)
[EN] Background: This study aimed to evaluate the accuracy of Dexcom G6 (DG6) and FreeStyle Libre-2 (FSL2) during aerobic training and high-intensity interval training (HIIT) in individuals with type 1 diabetes. Methods: ...
Barceló-Rico, Fátima; Diez, José-Luís; Rossetti, Paolo; Vehi, Josep; Bondía Company, Jorge(Institute of Electrical and Electronics Engineers, 2013)
[EN] Minimally or noninvasive continuous glucose monitors estimate plasma glucose from compartments alternative to blood, and may revolutionize the management of diabetes. However, the accuracy of current devices is still ...
Sanz Diaz, Ricardo; García Gil, Pedro José; Diez, José-Luís; Bondía Company, Jorge(Institute of Electrical and Electronics Engineers, 2021-01)
[EN] This brief is focused on the closed-loop control of postprandial glucose levels of patients with type 1 diabetes mellitus after unannounced meals, which is still a major challenge toward a fully autonomous artificial ...
[EN] Objective: To evaluate the safety and performance of a new multivariable closed-loop (MCL) glucose controller with automatic carbohydrate recommendation during and after unannounced and announced exercise in adults ...
[EN] Accurate blood glucose (BG) forecasting is key in diabetes management, as it allows preventive actions to mitigate harmful hypoglycemic/hyperglycemic episodes. Considering the encouraging results obtained by seasonal ...
[EN] Background: People with insulin-dependent diabetes rely on an intensified insulin regimen. Despite several guidelines, they
are usually impractical and fall short in achieving optimal glycemic outcomes. In this work, ...
Revert, Ana; Calm, Remei; Vehí, Josep; Bondía Company, Jorge(Institute of Electrical and Electronics Engineers, 2011-02)
[EN] Intensive insulin therapy in type 1 diabetes is based on the well-established practice of adjusting basal and bolus insulin independently. Basal insulin delivery is designed to optimize glucose concentrations between ...
[EN] In this paper, the problem of tackling uncertainty in the prediction of postprandial blood glucose is analyzed. Two simulation approaches, Monte Carlo and interval models, are studied and compared. Interval simulation ...
[EN] Continuous glucose monitors (CGM) have improved the management of patients with type 1 diabetes (T1D), with glucose oxidase (GOx)-based sensors being the most used. However, they are potentially subject to both ...
[EN] Many problems are confronted when characterizing a type 1 diabetic patient such as model mismatches, noisy inputs, measurement errors and huge variability in the glucose profiles. In this work we introduce a new ...
[EN] Background:
Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances ...
[EN] Accurate glucose prediction along a long-enough time horizon is a key component for technology to improve type 1 diabetes treatment. Subjects with diabetes might benefit from supervision and control systems that ...
[EN] High intensity interval training (HIIT) using elastic bands is easy to do, but no data on its impact on glycemic control in people with type 1 diabetes (T1D) are available. Six males with T1D performed three weekly ...
Sanz Diaz, Ricardo; Sala-Mira, Iván; Furió-Novejarque, Clara; García Gil, Pedro José; Diez, José-Luís; Bondía Company, Jorge(Elsevier, 2024-08-24)
[EN] Artificial pancreas systems should be designed considering different patient profiles, which is challenging from a control theory perspective. In this paper, a flexible-hybrid dual-hormone control algorithm for an ...
[EN] The aim of this study was to apply a methodology based on compositional data analysis (CoDA) to categorise glucose profiles obtained from continuous glucose monitoring systems. The methodology proposed considers ...
Considering the difficulty in selecting correct insulin doses and the problem of hyper- and hypoglycemia episodes in type 1 diabetes, dosage-aid systems are very useful for these patients. A model-based approach to this ...
Sala-Mira, Iván; García Gil, Pedro José; Diez, José-Luís; Bondia, Jorge(Elsevier, 2022-11)
[EN] Background and Objectives
Hybrid artificial pancreas systems outperform current insulin pump therapies in blood glucose regulation in type 1 diabetes. However, subjects still have to inform the system about meals ...